Development of a reverse transcription loop-mediated isothermal amplification assay with novel quantitative pH biosensor readout method for SARS-CoV-2 detection

IF 2.2 4区 医学 Q4 IMMUNOLOGY
Apmis Pub Date : 2024-04-25 DOI:10.1111/apm.13415
Dian Ekayanti Astari, Muhammad Nasrum Massi, Rina Masadah, Marhaen Hardjo, Rosdiana Natzir, Michael Erlichster, Gursharan Chana, Efstratios Skafidas, Zeba Islam Seraj, Sabrina M. Elias, Gita Vita Soraya
{"title":"Development of a reverse transcription loop-mediated isothermal amplification assay with novel quantitative pH biosensor readout method for SARS-CoV-2 detection","authors":"Dian Ekayanti Astari,&nbsp;Muhammad Nasrum Massi,&nbsp;Rina Masadah,&nbsp;Marhaen Hardjo,&nbsp;Rosdiana Natzir,&nbsp;Michael Erlichster,&nbsp;Gursharan Chana,&nbsp;Efstratios Skafidas,&nbsp;Zeba Islam Seraj,&nbsp;Sabrina M. Elias,&nbsp;Gita Vita Soraya","doi":"10.1111/apm.13415","DOIUrl":null,"url":null,"abstract":"<p>Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a molecular amplification method that can detect SARS-CoV-2 in a shorter time than the current gold-standard molecular diagnostic reverse transcription-polymerase chain reaction (RT-PCR). However, previously developed RT-LAMP assays have mostly relied on highly subjective visual colorimetric interpretation. In this study, an RT-LAMP assay was developed with quantitative measurement of reaction pH using a novel portable pH biosensor compared to qualitative colorimetric interpretation and gel electrophoresis, with 57 clinical COVID-19 samples used for validation of the test. The LoD of the assay is 10<sup>3</sup> copies/μL. The highest sensitivity was found in the qualitative methods (93.75%), while the highest specificity and likelihood ratio was found in the pH sensor (87.5% and 6.72). On the sensor measurement, a significant difference (p &lt; 0.0001) was observed between the average pH of the RT-PCR (+) COVID-19 (6.15 ± 0.27), while the average pH of the RT-PCR (−) samples (6.72 ± 0.22). Correlation analysis revealed a strong correlation (r = 0.78, p &lt; 0.0001) between the Ct values obtained from RT-PCR with the biosensor pH readout. RT-LAMP with the quantitative pH sensor readout method has the potential to be further developed as an objective molecular assay for rapid and simple detection of SARS-CoV-2.</p>","PeriodicalId":8167,"journal":{"name":"Apmis","volume":"132 7","pages":"499-506"},"PeriodicalIF":2.2000,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Apmis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/apm.13415","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a molecular amplification method that can detect SARS-CoV-2 in a shorter time than the current gold-standard molecular diagnostic reverse transcription-polymerase chain reaction (RT-PCR). However, previously developed RT-LAMP assays have mostly relied on highly subjective visual colorimetric interpretation. In this study, an RT-LAMP assay was developed with quantitative measurement of reaction pH using a novel portable pH biosensor compared to qualitative colorimetric interpretation and gel electrophoresis, with 57 clinical COVID-19 samples used for validation of the test. The LoD of the assay is 103 copies/μL. The highest sensitivity was found in the qualitative methods (93.75%), while the highest specificity and likelihood ratio was found in the pH sensor (87.5% and 6.72). On the sensor measurement, a significant difference (p < 0.0001) was observed between the average pH of the RT-PCR (+) COVID-19 (6.15 ± 0.27), while the average pH of the RT-PCR (−) samples (6.72 ± 0.22). Correlation analysis revealed a strong correlation (r = 0.78, p < 0.0001) between the Ct values obtained from RT-PCR with the biosensor pH readout. RT-LAMP with the quantitative pH sensor readout method has the potential to be further developed as an objective molecular assay for rapid and simple detection of SARS-CoV-2.

开发反转录环介导等温扩增测定法和新型 pH 生物传感器定量读出法,用于检测 SARS-CoV-2
反转录环介导等温扩增(RT-LAMP)是一种分子扩增方法,与目前的黄金标准分子诊断反转录聚合酶链反应(RT-PCR)相比,它能在更短的时间内检测出 SARS-CoV-2 病毒。然而,以前开发的 RT-LAMP 检测方法大多依赖于非常主观的目测比色法。本研究开发了一种 RT-LAMP 检测方法,使用新型便携式 pH 值生物传感器定量测量反应 pH 值,并与定性比色判读和凝胶电泳进行比较。该检测方法的 LoD 为 103 个拷贝/μL。定性方法的灵敏度最高(93.75%),而 pH 传感器的特异性和似然比最高(87.5% 和 6.72)。在传感器测量方面,RT-PCR (+) COVID-19 的平均 pH 值(6.15 ± 0.27)与 RT-PCR (-) 样品的平均 pH 值(6.72 ± 0.22)之间存在显著差异(p < 0.0001)。相关分析表明,RT-PCR 获得的 Ct 值与生物传感器 pH 读数之间存在很强的相关性(r = 0.78,p < 0.0001)。RT-LAMP与定量pH传感器读数法有可能进一步发展成为一种客观的分子检测方法,用于快速、简单地检测SARS-CoV-2。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Apmis
Apmis 医学-病理学
CiteScore
5.20
自引率
0.00%
发文量
91
审稿时长
2 months
期刊介绍: APMIS, formerly Acta Pathologica, Microbiologica et Immunologica Scandinavica, has been published since 1924 by the Scandinavian Societies for Medical Microbiology and Pathology as a non-profit-making scientific journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信