The 2-Minutes Walking Test Is Not Correlated with Aerobic Fitness Indices but with the 5-Times Sit-to-Stand Test Performance in Apparently Healthy Older Adults.
M. Gil-Calvo, JOSE ANTONIO DE PAZ, Alba Herrero-Molleda, Arthur Zecchin, María Teresa Gómez-Alonso, Beatriz Alonso-Cortés, Daniel Boullosa
{"title":"The 2-Minutes Walking Test Is Not Correlated with Aerobic Fitness Indices but with the 5-Times Sit-to-Stand Test Performance in Apparently Healthy Older Adults.","authors":"M. Gil-Calvo, JOSE ANTONIO DE PAZ, Alba Herrero-Molleda, Arthur Zecchin, María Teresa Gómez-Alonso, Beatriz Alonso-Cortés, Daniel Boullosa","doi":"10.3390/geriatrics9020043","DOIUrl":null,"url":null,"abstract":"The 2-minutes walking test (2-MWT) is a valid and reliable test that has a high correlation with the distance walked in the 6-minutes walking test (6-MWT). However, to date, no study has determined the relationship between 2-MWT performance and the aerobic fitness indices obtained during a maximal incremental test to confirm if this test is a valid surrogate of aerobic fitness in apparently healthy older adults. The main objective of this work was to identify the factors associated to the performance in the 2-MWT, including aerobic fitness, functional and spatial-temporal gait parameters. Seventeen elderly adults performed a maximal incremental cycling test to determine maximum oxygen consumption (VO2max) and ventilatory thresholds (VT1 and VT2), two static standing balance tests with open and close eyes, a 5-times sit-to-stand test (5-TSTS), a handgrip test, and a 2-MWT on three different days over 2 weeks. No correlations were found between aerobic fitness indices and the distance covered in 2-MWT, but significant moderate correlations were found between the distance covered in 2-MWT and the time to perform the 5-TSTS (rho = -0.49) and with stride length (rho = 0.52) during the test. In conclusion, the 2-MWT does not seem a good test to assess aerobic capacity while it showed to be associated to the 5-TSTS performance of the elderly.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"273 ","pages":""},"PeriodicalIF":4.6000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/geriatrics9020043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
The 2-minutes walking test (2-MWT) is a valid and reliable test that has a high correlation with the distance walked in the 6-minutes walking test (6-MWT). However, to date, no study has determined the relationship between 2-MWT performance and the aerobic fitness indices obtained during a maximal incremental test to confirm if this test is a valid surrogate of aerobic fitness in apparently healthy older adults. The main objective of this work was to identify the factors associated to the performance in the 2-MWT, including aerobic fitness, functional and spatial-temporal gait parameters. Seventeen elderly adults performed a maximal incremental cycling test to determine maximum oxygen consumption (VO2max) and ventilatory thresholds (VT1 and VT2), two static standing balance tests with open and close eyes, a 5-times sit-to-stand test (5-TSTS), a handgrip test, and a 2-MWT on three different days over 2 weeks. No correlations were found between aerobic fitness indices and the distance covered in 2-MWT, but significant moderate correlations were found between the distance covered in 2-MWT and the time to perform the 5-TSTS (rho = -0.49) and with stride length (rho = 0.52) during the test. In conclusion, the 2-MWT does not seem a good test to assess aerobic capacity while it showed to be associated to the 5-TSTS performance of the elderly.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.