Validity and Responsiveness of a Modified Balance Error Scoring System Assessment Using a Mobile Device Application in Patients Recovering from Ankle Sprain

IF 1.6 Q3 SPORT SCIENCES
Michael S. Crowell, Eliot Thomasma, E. Florkiewicz, Richard Brindle, Megan Roach, Donald Goss, Will Pitt
{"title":"Validity and Responsiveness of a Modified Balance Error Scoring System Assessment Using a Mobile Device Application in Patients Recovering from Ankle Sprain","authors":"Michael S. Crowell, Eliot Thomasma, E. Florkiewicz, Richard Brindle, Megan Roach, Donald Goss, Will Pitt","doi":"10.26603/001c.94608","DOIUrl":null,"url":null,"abstract":"Background Static balance is often impaired in patients after ankle sprains. The ability to identify static balance impairments is dependent on an effective balance assessment tool. The Sway Balance Mobile Application (SWAY App) (Sway Medical, Tulsa, OK) uses a smart phone or tablet to assess postural sway during a modified Balance Error Scoring System (mBESS) assessment and shows promise as an accessible method to quantify changes in static balance after injury. Purpose The primary purposes of this study were to determine the ability to differentiate between those with ankle sprain versus controls (construct validity) and ability to detect change over time (responsiveness) of a mBESS assessment using a mobile device application to evaluate static balance after an acute ankle sprain. Study Design Case-control study. Methods Twenty-two military academy Cadets with an acute ankle sprain and 20 healthy Cadets were enrolled in the study. All participants completed an assessment measuring self-reported function, ankle dorsiflexion range of motion (via the weightbearing lunge), dynamic balance, and static balance. Static balance measured with the mBESS using the SWAY App was validated against laboratory-based measures. Cadets with ankle sprains completed their assessment twice: once within two weeks of injury (baseline) and again after four weeks of rehabilitation that included balance training. Independent and paired t-tests were utilized to analyze differences over time and between groups. Effect sizes were calculated and relationships explored using Pearson’s correlation coefficients. Results The mBESS scores measured by the SWAY App were lower in participants with acute ankle sprains than healthy Cadets (t = 3.15, p = 0.004). Injured participants improved their mBESS score measured by SWAY at four weeks following their initial assessments (t = 3.31, p = 0.004; Baseline: 74.2 +/- 16.1, 4-weeks: 82.7 +/- 9.5). The mBESS measured by the SWAY App demonstrated moderate to good correlation with a laboratory measure of static balance (r = -0.59, p \\< 0.001). Conclusion The mBESS assessed with a mobile device application is a valid and responsive clinical tool for evaluating static balance. The tool demonstrated construct (known groups) validity detecting balance differences between a healthy and injured group, concurrent validity demonstrating moderate to good correlation with established laboratory measures, and responsiveness to changes in static balance in military Cadets during recovery from an acute ankle sprain. Level of Evidence Level 3","PeriodicalId":47892,"journal":{"name":"International Journal of Sports Physical Therapy","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Sports Physical Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26603/001c.94608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background Static balance is often impaired in patients after ankle sprains. The ability to identify static balance impairments is dependent on an effective balance assessment tool. The Sway Balance Mobile Application (SWAY App) (Sway Medical, Tulsa, OK) uses a smart phone or tablet to assess postural sway during a modified Balance Error Scoring System (mBESS) assessment and shows promise as an accessible method to quantify changes in static balance after injury. Purpose The primary purposes of this study were to determine the ability to differentiate between those with ankle sprain versus controls (construct validity) and ability to detect change over time (responsiveness) of a mBESS assessment using a mobile device application to evaluate static balance after an acute ankle sprain. Study Design Case-control study. Methods Twenty-two military academy Cadets with an acute ankle sprain and 20 healthy Cadets were enrolled in the study. All participants completed an assessment measuring self-reported function, ankle dorsiflexion range of motion (via the weightbearing lunge), dynamic balance, and static balance. Static balance measured with the mBESS using the SWAY App was validated against laboratory-based measures. Cadets with ankle sprains completed their assessment twice: once within two weeks of injury (baseline) and again after four weeks of rehabilitation that included balance training. Independent and paired t-tests were utilized to analyze differences over time and between groups. Effect sizes were calculated and relationships explored using Pearson’s correlation coefficients. Results The mBESS scores measured by the SWAY App were lower in participants with acute ankle sprains than healthy Cadets (t = 3.15, p = 0.004). Injured participants improved their mBESS score measured by SWAY at four weeks following their initial assessments (t = 3.31, p = 0.004; Baseline: 74.2 +/- 16.1, 4-weeks: 82.7 +/- 9.5). The mBESS measured by the SWAY App demonstrated moderate to good correlation with a laboratory measure of static balance (r = -0.59, p \< 0.001). Conclusion The mBESS assessed with a mobile device application is a valid and responsive clinical tool for evaluating static balance. The tool demonstrated construct (known groups) validity detecting balance differences between a healthy and injured group, concurrent validity demonstrating moderate to good correlation with established laboratory measures, and responsiveness to changes in static balance in military Cadets during recovery from an acute ankle sprain. Level of Evidence Level 3
使用移动设备应用程序评估踝关节扭伤康复患者的改良平衡失误评分系统的有效性和响应性
背景 踝关节扭伤后的患者通常会出现静态平衡障碍。识别静态平衡障碍的能力取决于有效的平衡评估工具。Sway 平衡移动应用程序(SWAY App)(Sway Medical, Tulsa, OK)使用智能手机或平板电脑在改良平衡失误评分系统(mBESS)评估过程中对姿势摇摆进行评估,并有望成为量化伤后静态平衡变化的便捷方法。目的 本研究的主要目的是确定使用移动设备应用程序评估急性踝关节扭伤后静态平衡的 mBESS 评估对踝关节扭伤患者和对照组的区分能力(结构效度)以及检测随时间变化的能力(响应性)。研究设计 病例对照研究。研究方法 22 名急性踝关节扭伤的军校学员和 20 名健康学员参加了研究。所有参与者都完成了一项评估,测量自我报告的功能、踝关节背屈运动范围(通过负重弓步)、动态平衡和静态平衡。通过使用 SWAY 应用程序的 mBESS 测量的静态平衡与实验室测量结果进行了验证。踝关节扭伤的学员完成了两次评估:一次是在受伤两周内(基线),另一次是在包括平衡训练在内的四周康复后。采用独立 t 检验和配对 t 检验分析不同时间段和不同组间的差异。使用皮尔逊相关系数计算效应大小并探讨两者之间的关系。结果 通过 SWAY 应用程序测量,急性踝关节扭伤学员的 mBESS 得分低于健康学员(t = 3.15,p = 0.004)。受伤学员在首次评估后四周通过 SWAY 测量的 mBESS 分数有所提高(t = 3.31,p = 0.004;基线:74.2 +/-16.1,四周:82.7 +/-9.5)。SWAY 应用程序测得的 mBESS 与实验室测得的静态平衡有中度到良好的相关性(r = -0.59,p < 0.001)。结论 使用移动设备应用程序评估的 mBESS 是一种有效且反应灵敏的临床静态平衡评估工具。该工具在检测健康组和受伤组之间的平衡差异方面表现出了构造(已知组)有效性,在与已建立的实验室测量方法之间表现出了中度到良好的相关性方面表现出了并发有效性,在急性踝关节扭伤恢复期间对军事学员静态平衡变化的反应能力方面也表现出了有效性。证据等级 3 级
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
5.90%
发文量
124
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信