A comparison of a handheld minicomputer and an external graphics processing unit in performing 3D intraoral scans

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Taseef Hasan Farook BDS, MScDent , James Dudley BDS, DClinDent
{"title":"A comparison of a handheld minicomputer and an external graphics processing unit in performing 3D intraoral scans","authors":"Taseef Hasan Farook BDS, MScDent ,&nbsp;James Dudley BDS, DClinDent","doi":"10.1016/j.prosdent.2024.03.028","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>Whether the use of an external graphics processing unit (eGPU) and a handheld computer prolongs the operation time for 3-dimensional (3D) intraoral scanning or produces clinically unacceptable scans is unclear.</div></div><div><h3>Purpose</h3><div>The purpose of this in vitro study was to compare the 3D intraoral scan accuracy and scan time of a small portable device and an eGPU with desktop-grade workstations.</div></div><div><h3>Material and methods</h3><div>A handheld computer, a laptop, a desktop workstation, and an external graphics card were used to scan a 3D printed set of maxillary and mandibular casts 10 consecutive times using an intraoral scanner. The casts were provided by the manufacturers of the scanner, and the scanning process was conducted by a single operator following best-practice methods. The time required to scan and process the 3D models was analyzed via 1-way ANOVA. Dimensional similarity was assessed using the Hausdorff distance (HD) across the resultant 80 independent bimaxillary 3D scans. A dental desktop 3D scanner was used to scan the casts which served as the control reference. HD values were analyzed via multifactorial ANOVA (α=.05).</div></div><div><h3>Results</h3><div>In the real-time rendering of 3D intraoral scans, the laptop without an eGPU took significantly longer (146.41 ±10.66 seconds) (F=30.58, <em>P</em>&lt;.001) compared with when connected to an eGPU (117.66 ±6.95 seconds) and handheld computer (114.84 ±7.20 seconds). Postprocessing times were more favorable on the desktop workstation (16.61 ±4.18 seconds) compared with the laptop with (27.85 ±8.89 seconds) and without an eGPU (32.37 ±7.16 seconds) connected, with the handheld computer and eGPU combination (14.66 ±7.37 seconds) producing the best results (F=14.60, <em>P</em>&lt;.001). Dimensional similarity assessments showed high consistency (F=0.92, <em>P</em>=.44), with no discrepancies noted on the prepared tooth surfaces. The handheld minicomputer with an eGPU produced the best results across all 4 groups.</div></div><div><h3>Conclusions</h3><div>The handheld computer with an eGPU offered 3D intraoral scans comparable with output from a traditional workstation while preserving the details on the tooth preparations but at significantly faster scanning and processing rates.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"133 2","pages":"Pages 568-574"},"PeriodicalIF":4.3000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391324002221","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

Whether the use of an external graphics processing unit (eGPU) and a handheld computer prolongs the operation time for 3-dimensional (3D) intraoral scanning or produces clinically unacceptable scans is unclear.

Purpose

The purpose of this in vitro study was to compare the 3D intraoral scan accuracy and scan time of a small portable device and an eGPU with desktop-grade workstations.

Material and methods

A handheld computer, a laptop, a desktop workstation, and an external graphics card were used to scan a 3D printed set of maxillary and mandibular casts 10 consecutive times using an intraoral scanner. The casts were provided by the manufacturers of the scanner, and the scanning process was conducted by a single operator following best-practice methods. The time required to scan and process the 3D models was analyzed via 1-way ANOVA. Dimensional similarity was assessed using the Hausdorff distance (HD) across the resultant 80 independent bimaxillary 3D scans. A dental desktop 3D scanner was used to scan the casts which served as the control reference. HD values were analyzed via multifactorial ANOVA (α=.05).

Results

In the real-time rendering of 3D intraoral scans, the laptop without an eGPU took significantly longer (146.41 ±10.66 seconds) (F=30.58, P<.001) compared with when connected to an eGPU (117.66 ±6.95 seconds) and handheld computer (114.84 ±7.20 seconds). Postprocessing times were more favorable on the desktop workstation (16.61 ±4.18 seconds) compared with the laptop with (27.85 ±8.89 seconds) and without an eGPU (32.37 ±7.16 seconds) connected, with the handheld computer and eGPU combination (14.66 ±7.37 seconds) producing the best results (F=14.60, P<.001). Dimensional similarity assessments showed high consistency (F=0.92, P=.44), with no discrepancies noted on the prepared tooth surfaces. The handheld minicomputer with an eGPU produced the best results across all 4 groups.

Conclusions

The handheld computer with an eGPU offered 3D intraoral scans comparable with output from a traditional workstation while preserving the details on the tooth preparations but at significantly faster scanning and processing rates.
比较手持式微型计算机和外置图形处理单元在进行 3D 口腔内扫描时的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信