{"title":"Description and evaluation of a self-operated waist measurement device","authors":"Yilin Song, Kenneth A Philbrick, Alexander D Weston, Theodora Potretzke, Kelli A Lytle, Teresa Jensen, Michael D Jensen","doi":"10.1136/bmjinnov-2023-001162","DOIUrl":null,"url":null,"abstract":"National guidelines recommend that waist circumference (WC) be measured in patients with a body mass index (BMI) 27–35 kg/m2. Unfortunately, perhaps due to logistical reasons, WC is seldom measured in clinical settings. Herein, we describe the performance of a self-operated waist measurement device (SOWMD) as a potential means to overcome barriers to measuring WC.Ten volunteers underwent WC measures by professionals and SOWMD on 5 separate days to assess the reproducibility and accuracy. We then compared SOWMD measures with CT-derived fat content by recruiting 81 patients scheduled for a diagnostic abdominal CT scan.There was no difference between professionally measured and SOWMD-measured WC; the intraindividual coefficient of variation over the 5 days was between 0.4% and 2.2%. The WC measured manually, by SOWMD and CT scan were highly correlated (r=0.90–0.92, all p<0.001). The minimal WC measured by SOWMD was a better predictor (r=0.81 for all patients, r=0.87 for men, both p<0.001) of CT-measured visceral adipose tissue volume than other approaches. The minimal WC measured by SOWMD was correlated with fasting plasma glucose (r=0.40, p<0.05), triglyceride (r=0.41, p<0.01) and high-density cholesterol (r=−0.49, p<0.001) concentrations.SOWMD is a reproducible, accurate and convenient way to measure WC that can provide added value for health care providers when combined with BMI information.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"19 4","pages":""},"PeriodicalIF":16.4000,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjinnov-2023-001162","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

National guidelines recommend that waist circumference (WC) be measured in patients with a body mass index (BMI) 27–35 kg/m2. Unfortunately, perhaps due to logistical reasons, WC is seldom measured in clinical settings. Herein, we describe the performance of a self-operated waist measurement device (SOWMD) as a potential means to overcome barriers to measuring WC.Ten volunteers underwent WC measures by professionals and SOWMD on 5 separate days to assess the reproducibility and accuracy. We then compared SOWMD measures with CT-derived fat content by recruiting 81 patients scheduled for a diagnostic abdominal CT scan.There was no difference between professionally measured and SOWMD-measured WC; the intraindividual coefficient of variation over the 5 days was between 0.4% and 2.2%. The WC measured manually, by SOWMD and CT scan were highly correlated (r=0.90–0.92, all p<0.001). The minimal WC measured by SOWMD was a better predictor (r=0.81 for all patients, r=0.87 for men, both p<0.001) of CT-measured visceral adipose tissue volume than other approaches. The minimal WC measured by SOWMD was correlated with fasting plasma glucose (r=0.40, p<0.05), triglyceride (r=0.41, p<0.01) and high-density cholesterol (r=−0.49, p<0.001) concentrations.SOWMD is a reproducible, accurate and convenient way to measure WC that can provide added value for health care providers when combined with BMI information.
自动腰围测量装置的描述和评估
国家指南建议,体重指数(BMI)为 27-35 kg/m2 的患者应测量腰围(WC)。遗憾的是,也许是由于后勤方面的原因,临床上很少测量腰围。在此,我们介绍了自操作腰围测量装置(SOWMD)的性能,它是克服测量腰围障碍的一种潜在手段。10 名志愿者分别在 5 天内接受了专业人员和 SOWMD 的腰围测量,以评估其重现性和准确性。然后,我们招募了 81 名计划接受腹部 CT 扫描诊断的患者,将 SOWMD 测量值与 CT 导出的脂肪含量进行比较。人工、SOWMD 和 CT 扫描测量的腹围高度相关(r=0.90-0.92,均 p<0.001)。与其他方法相比,SOWMD 测量的最小腹围能更好地预测 CT 测量的内脏脂肪组织体积(所有患者的 r=0.81,男性 r=0.87,均 p<0.001)。SOWMD 测量的最小腹围与空腹血浆葡萄糖(r=0.40,p<0.05)、甘油三酯(r=0.41,p<0.01)和高密度胆固醇(r=-0.49,p<0.001)的浓度相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信