Yilin Song, Kenneth A Philbrick, Alexander D Weston, Theodora Potretzke, Kelli A Lytle, Teresa Jensen, Michael D Jensen
{"title":"Description and evaluation of a self-operated waist measurement device","authors":"Yilin Song, Kenneth A Philbrick, Alexander D Weston, Theodora Potretzke, Kelli A Lytle, Teresa Jensen, Michael D Jensen","doi":"10.1136/bmjinnov-2023-001162","DOIUrl":null,"url":null,"abstract":"National guidelines recommend that waist circumference (WC) be measured in patients with a body mass index (BMI) 27–35 kg/m2. Unfortunately, perhaps due to logistical reasons, WC is seldom measured in clinical settings. Herein, we describe the performance of a self-operated waist measurement device (SOWMD) as a potential means to overcome barriers to measuring WC.Ten volunteers underwent WC measures by professionals and SOWMD on 5 separate days to assess the reproducibility and accuracy. We then compared SOWMD measures with CT-derived fat content by recruiting 81 patients scheduled for a diagnostic abdominal CT scan.There was no difference between professionally measured and SOWMD-measured WC; the intraindividual coefficient of variation over the 5 days was between 0.4% and 2.2%. The WC measured manually, by SOWMD and CT scan were highly correlated (r=0.90–0.92, all p<0.001). The minimal WC measured by SOWMD was a better predictor (r=0.81 for all patients, r=0.87 for men, both p<0.001) of CT-measured visceral adipose tissue volume than other approaches. The minimal WC measured by SOWMD was correlated with fasting plasma glucose (r=0.40, p<0.05), triglyceride (r=0.41, p<0.01) and high-density cholesterol (r=−0.49, p<0.001) concentrations.SOWMD is a reproducible, accurate and convenient way to measure WC that can provide added value for health care providers when combined with BMI information.","PeriodicalId":53454,"journal":{"name":"BMJ Innovations","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Innovations","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjinnov-2023-001162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
Abstract
National guidelines recommend that waist circumference (WC) be measured in patients with a body mass index (BMI) 27–35 kg/m2. Unfortunately, perhaps due to logistical reasons, WC is seldom measured in clinical settings. Herein, we describe the performance of a self-operated waist measurement device (SOWMD) as a potential means to overcome barriers to measuring WC.Ten volunteers underwent WC measures by professionals and SOWMD on 5 separate days to assess the reproducibility and accuracy. We then compared SOWMD measures with CT-derived fat content by recruiting 81 patients scheduled for a diagnostic abdominal CT scan.There was no difference between professionally measured and SOWMD-measured WC; the intraindividual coefficient of variation over the 5 days was between 0.4% and 2.2%. The WC measured manually, by SOWMD and CT scan were highly correlated (r=0.90–0.92, all p<0.001). The minimal WC measured by SOWMD was a better predictor (r=0.81 for all patients, r=0.87 for men, both p<0.001) of CT-measured visceral adipose tissue volume than other approaches. The minimal WC measured by SOWMD was correlated with fasting plasma glucose (r=0.40, p<0.05), triglyceride (r=0.41, p<0.01) and high-density cholesterol (r=−0.49, p<0.001) concentrations.SOWMD is a reproducible, accurate and convenient way to measure WC that can provide added value for health care providers when combined with BMI information.
期刊介绍:
Healthcare is undergoing a revolution and novel medical technologies are being developed to treat patients in better and faster ways. Mobile revolution has put a handheld computer in pockets of billions and we are ushering in an era of mHealth. In developed and developing world alike healthcare costs are a concern and frugal innovations are being promoted for bringing down the costs of healthcare. BMJ Innovations aims to promote innovative research which creates new, cost-effective medical devices, technologies, processes and systems that improve patient care, with particular focus on the needs of patients, physicians, and the health care industry as a whole and act as a platform to catalyse and seed more innovations. Submissions to BMJ Innovations will be considered from all clinical areas of medicine along with business and process innovations that make healthcare accessible and affordable. Submissions from groups of investigators engaged in international collaborations are especially encouraged. The broad areas of innovations that this journal aims to chronicle include but are not limited to: Medical devices, mHealth and wearable health technologies, Assistive technologies, Diagnostics, Health IT, systems and process innovation.