Automated radiographic hip morphology measurements: An open-access method

F. Boel , S. de Vos-Jakobs , N.S. Riedstra , C. Lindner , J. Runhaar , S.M.A. Bierma-Zeinstra , R. Agricola
{"title":"Automated radiographic hip morphology measurements: An open-access method","authors":"F. Boel ,&nbsp;S. de Vos-Jakobs ,&nbsp;N.S. Riedstra ,&nbsp;C. Lindner ,&nbsp;J. Runhaar ,&nbsp;S.M.A. Bierma-Zeinstra ,&nbsp;R. Agricola","doi":"10.1016/j.ostima.2024.100181","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>The aim of this study is to present a newly developed automated method to determine radiographic measurements of hip morphology on dual-energy x-ray absorptiometry (DXA) images. The secondary aim was to compare the performance of the automated and manual measurements.</p></div><div><h3>Design</h3><p>30 DXA scans from 13-year-olds of the prospective population-based cohort study Generation R were randomly selected. The hip shape was outlined automatically using radiographic landmarks from which the acetabular depth-width ratio (ADR), acetabular index (AI), alpha angle (AA), Wiberg and lateral center edge angle (WCEA) (LCEA), extrusion index (EI), neck-shaft angle (NSA), and the triangular index (TI) were determined. Manual assessments were performed twice by two orthopedic surgeons. The agreement within and between observers and methods was visualized using Bland-Altman plots, and the reliability was studied using the intraclass correlation coefficient (ICC) with 95 % confidence intervals (CI).</p></div><div><h3>Results</h3><p>The automated method was able to perform all radiographic hip morphology measurements. The intermethod reliability between the automated and manual measurements ranged from 0.57 to 0.96 and was comparable to or better than the manual interobserver reliability, except for the AI.</p></div><div><h3>Conclusion</h3><p>This open-access, automated method allows fast and reproducible calculation of radiographic measurements of hip morphology on right hip DXA images. It is a promising tool for performing automated radiographic measurements of hip morphology in large population studies and clinical practice.</p></div>","PeriodicalId":74378,"journal":{"name":"Osteoarthritis imaging","volume":"4 2","pages":"Article 100181"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772654124000096/pdfft?md5=a7201343adac06404676edd58494c30e&pid=1-s2.0-S2772654124000096-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Osteoarthritis imaging","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772654124000096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

The aim of this study is to present a newly developed automated method to determine radiographic measurements of hip morphology on dual-energy x-ray absorptiometry (DXA) images. The secondary aim was to compare the performance of the automated and manual measurements.

Design

30 DXA scans from 13-year-olds of the prospective population-based cohort study Generation R were randomly selected. The hip shape was outlined automatically using radiographic landmarks from which the acetabular depth-width ratio (ADR), acetabular index (AI), alpha angle (AA), Wiberg and lateral center edge angle (WCEA) (LCEA), extrusion index (EI), neck-shaft angle (NSA), and the triangular index (TI) were determined. Manual assessments were performed twice by two orthopedic surgeons. The agreement within and between observers and methods was visualized using Bland-Altman plots, and the reliability was studied using the intraclass correlation coefficient (ICC) with 95 % confidence intervals (CI).

Results

The automated method was able to perform all radiographic hip morphology measurements. The intermethod reliability between the automated and manual measurements ranged from 0.57 to 0.96 and was comparable to or better than the manual interobserver reliability, except for the AI.

Conclusion

This open-access, automated method allows fast and reproducible calculation of radiographic measurements of hip morphology on right hip DXA images. It is a promising tool for performing automated radiographic measurements of hip morphology in large population studies and clinical practice.

髋关节放射形态自动测量:公开获取方法
本研究旨在介绍一种新开发的自动方法,用于确定双能 X 射线吸收测量(DXA)图像上髋关节形态的放射学测量值。设计随机选取前瞻性人群队列研究 Generation R 中 30 名 13 岁儿童的 DXA 扫描图像。利用放射学地标自动勾勒出髋部形状,并据此确定髋臼深宽比 (ADR)、髋臼指数 (AI)、α 角 (AA)、Wiberg 和外侧中心边缘角 (WCEA) (LCEA)、挤压指数 (EI)、颈轴角 (NSA) 和三角指数 (TI)。人工评估由两名骨科医生进行两次。使用 Bland-Altman 图显示观察者内部和观察者与方法之间的一致性,并使用带 95 % 置信区间 (CI) 的类内相关系数 (ICC) 研究可靠性。自动测量与人工测量之间的方法间可靠性在 0.57 到 0.96 之间,除人工指数外,与人工测量的观察者间可靠性相当或更好。它是在大型人群研究和临床实践中对髋关节形态进行自动放射学测量的一种很有前途的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Osteoarthritis imaging
Osteoarthritis imaging Radiology and Imaging
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信