Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

IF 8.4 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Building and Environment Pub Date : 2024-06-01 Epub Date: 2024-04-02 DOI:10.1016/j.buildenv.2024.111466
Cary A. Faulkner , Timothy I. Salsbury , Belal Abboushi , Cerrina Mouchref , Brett C. Singer , Michael D. Sohn , Gabe Arnold
{"title":"Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building","authors":"Cary A. Faulkner ,&nbsp;Timothy I. Salsbury ,&nbsp;Belal Abboushi ,&nbsp;Cerrina Mouchref ,&nbsp;Brett C. Singer ,&nbsp;Michael D. Sohn ,&nbsp;Gabe Arnold","doi":"10.1016/j.buildenv.2024.111466","DOIUrl":null,"url":null,"abstract":"<div><p>Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. This paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.</p></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"257 ","pages":"Article 111466"},"PeriodicalIF":8.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360132324003081","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. This paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

比较空气传播病原体缓解措施的效果和能源使用,以实现原型办公楼的清洁空气目标
美国建筑工程师学会(ASHRAE)和美国疾病控制与预防中心(CDC)等组织提出了控制建筑物内传染性气溶胶的指导方针,这些指导方针可以通过改变供暖、通风和空调系统(HVAC)的运行方式或采用空气净化技术等措施来实现。然而,在为这些准则设计措施时,需要进行更多的研究来了解健康、能源和舒适度之间的权衡。为了弥补这一不足,本文使用空气清洁技术的新模型进行了分析,包括室内和室外紫外线杀菌系统(GUV)以及便携式空气清洁器(PAC)。这些模型被纳入现有的办公建筑原型模型中,并设计了六种措施来满足 ASHRAE 标准 241 和 CDC 的清洁空气目标:MERV 13 HVAC 过滤、最大限度地向建筑物供应室外空气、PAC 以及室内、上层和整个房间的 GUV。这些措施是针对一栋气候凉爽潮湿的办公楼进行的模拟,并与使用 MERV 8 过滤的基线模拟进行了比较。结果表明,除最大室外空气案例外,所有措施都能满足 ASHRAE 241 标准,且不会对能源或舒适度产生重大影响。暖通空调系统措施在默认系统尺寸下无法达到 CDC 目标,并导致能耗大幅增加,而室内措施能够达到 CDC 目标,但对能耗影响较小。本文总结了模拟结果,并为建筑运营商提供了实用指导,以实现清洁空气目标,同时限制对能源和舒适度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Building and Environment
Building and Environment 工程技术-工程:环境
CiteScore
12.50
自引率
23.00%
发文量
1130
审稿时长
27 days
期刊介绍: Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书