Daniel Fernández-Martínez, María Reyes González-Fernández, Juan Manuel Nogales-Asensio, Conrado Ferrera
{"title":"Impact of minimal lumen segmentation uncertainty on patient-specific coronary simulations: A look at FFRCT","authors":"Daniel Fernández-Martínez, María Reyes González-Fernández, Juan Manuel Nogales-Asensio, Conrado Ferrera","doi":"10.1002/cnm.3822","DOIUrl":null,"url":null,"abstract":"<p>We examined the effect of minimal lumen segmentation uncertainty on Fractional Flow Reserve obtained from Coronary Computed Tomography Angiography <span></span><math>\n <mrow>\n <mfenced>\n <msub>\n <mi>FFR</mi>\n <mi>CT</mi>\n </msub>\n </mfenced>\n </mrow></math>. A total of 14 patient-specific coronary models with different stenosis locations and degrees of severity were enrolled in this study. The optimal segmented coronary lumens were disturbed using intra <span></span><math>\n <mrow>\n <mfenced>\n <mrow>\n <mo>±</mo>\n <mn>6</mn>\n <mo>%</mo>\n </mrow>\n </mfenced>\n </mrow></math> and inter-operator <span></span><math>\n <mrow>\n <mfenced>\n <mrow>\n <mo>±</mo>\n <mn>15</mn>\n <mo>%</mo>\n </mrow>\n </mfenced>\n </mrow></math> variations on the segmentation threshold. <span></span><math>\n <mrow>\n <msub>\n <mi>FFR</mi>\n <mi>CT</mi>\n </msub>\n </mrow></math> was evaluated in each case by 3D-OD CFD simulations. The findings suggest that the sensitivity of <span></span><math>\n <mrow>\n <msub>\n <mi>FFR</mi>\n <mi>CT</mi>\n </msub>\n </mrow></math> to this type of uncertainty increases distally and with the stenosis severity. Cases with moderate or severe distal coronary lesions should undergo either exact and thorough segmentation operations or invasive FFR measurements, particularly if the <span></span><math>\n <mrow>\n <msub>\n <mi>FFR</mi>\n <mi>CT</mi>\n </msub>\n </mrow></math> is close to the cutoff (0.80). Therefore, we conclude that it is crucial to consider the lesion's location and degree of severity when evaluating <span></span><math>\n <mrow>\n <msub>\n <mi>FFR</mi>\n <mi>CT</mi>\n </msub>\n </mrow></math> results.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"40 6","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cnm.3822","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.3822","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
We examined the effect of minimal lumen segmentation uncertainty on Fractional Flow Reserve obtained from Coronary Computed Tomography Angiography . A total of 14 patient-specific coronary models with different stenosis locations and degrees of severity were enrolled in this study. The optimal segmented coronary lumens were disturbed using intra and inter-operator variations on the segmentation threshold. was evaluated in each case by 3D-OD CFD simulations. The findings suggest that the sensitivity of to this type of uncertainty increases distally and with the stenosis severity. Cases with moderate or severe distal coronary lesions should undergo either exact and thorough segmentation operations or invasive FFR measurements, particularly if the is close to the cutoff (0.80). Therefore, we conclude that it is crucial to consider the lesion's location and degree of severity when evaluating results.
期刊介绍:
All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.