Manish Srivastava;Kilian O’Donoghue;Aleksandr Sidun;Herman Alexander Jaeger;Alessandro Ferro;Daragh Crowley;Christian van den Bosch;Marcus Kennedy;Daniel O’Hare;Pádraig Cantillon-Murphy
{"title":"3D Position Tracking Using On-Chip Magnetic Sensing in Image-Guided Navigation Bronchoscopy","authors":"Manish Srivastava;Kilian O’Donoghue;Aleksandr Sidun;Herman Alexander Jaeger;Alessandro Ferro;Daragh Crowley;Christian van den Bosch;Marcus Kennedy;Daniel O’Hare;Pádraig Cantillon-Murphy","doi":"10.1109/TBCAS.2024.3384016","DOIUrl":null,"url":null,"abstract":"This paper presents a compact and low-cost on-chip sensor and readout circuit. The sensor achieves high-resolution 5-degrees-of-freedom (DoF) tracking (x, y, z, yaw, and pitch). With the help of an external wire wound sensor, it can also achieve high-resolution 6-degrees-of-freedom (DoF) tracking (x, y, z, yaw, pitch, and roll angles). The sensor uses low-frequency magnetic fields to detect the position and orientation of instruments, providing a viable alternative to using X-rays in image-guided surgery. To measure the local magnetic field, a highly miniaturised on-chip magnetic sensor capable of sensing the magnetic field has been developed incorporating an on-chip magnetic sensor coil, analog-front end, continuous-time \n<inline-formula><tex-math>$\\Delta\\Sigma$</tex-math></inline-formula>\n analog-to-digital converter (ADC), LVDS transmitter, bandgap reference, and voltage regulator. The microchip is fabricated using 65 nm CMOS technology and occupies an area of 1.06 mm\n<inline-formula><tex-math>${}^{2}$</tex-math></inline-formula>\n, the smallest reported among similar designs to the best of our knowledge. The 5-DoF system accurately navigates with a precision of 1.1 mm within the volume-of-interest (VOI) of 15\n<inline-formula><tex-math>$\\times$</tex-math></inline-formula>\n15\n<inline-formula><tex-math>$\\times$</tex-math></inline-formula>\n15 cm\n<inline-formula><tex-math>${}^{3}$</tex-math></inline-formula>\n. The 6-DoF system achieves a navigation accuracy of 0.8 mm and an angular error of 1.1 degrees in the same VOI. These results were obtained at a 20 Hz update rate in benchtop characterisation. The prototype sensor demonstrates accurate position tracking in real-life pre-clinical \n<italic>in-vivo</i>\n settings within the porcine lung of a live swine, achieving a reported worst-case registration accuracy of 5.8 mm.","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10489984/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents a compact and low-cost on-chip sensor and readout circuit. The sensor achieves high-resolution 5-degrees-of-freedom (DoF) tracking (x, y, z, yaw, and pitch). With the help of an external wire wound sensor, it can also achieve high-resolution 6-degrees-of-freedom (DoF) tracking (x, y, z, yaw, pitch, and roll angles). The sensor uses low-frequency magnetic fields to detect the position and orientation of instruments, providing a viable alternative to using X-rays in image-guided surgery. To measure the local magnetic field, a highly miniaturised on-chip magnetic sensor capable of sensing the magnetic field has been developed incorporating an on-chip magnetic sensor coil, analog-front end, continuous-time
$\Delta\Sigma$
analog-to-digital converter (ADC), LVDS transmitter, bandgap reference, and voltage regulator. The microchip is fabricated using 65 nm CMOS technology and occupies an area of 1.06 mm
${}^{2}$
, the smallest reported among similar designs to the best of our knowledge. The 5-DoF system accurately navigates with a precision of 1.1 mm within the volume-of-interest (VOI) of 15
$\times$
15
$\times$
15 cm
${}^{3}$
. The 6-DoF system achieves a navigation accuracy of 0.8 mm and an angular error of 1.1 degrees in the same VOI. These results were obtained at a 20 Hz update rate in benchtop characterisation. The prototype sensor demonstrates accurate position tracking in real-life pre-clinical
in-vivo
settings within the porcine lung of a live swine, achieving a reported worst-case registration accuracy of 5.8 mm.