Thermal analysis of solar energy based organic Rankine cycle cascaded with vapor compression refrigeration cycle

IF 8 Q1 ENERGY & FUELS
Mohammad Faizan Qureshi , Mohammad Waqas Chandio , Abdul Aleem Memon , Laveet Kumar , Mohamed M. Awad
{"title":"Thermal analysis of solar energy based organic Rankine cycle cascaded with vapor compression refrigeration cycle","authors":"Mohammad Faizan Qureshi ,&nbsp;Mohammad Waqas Chandio ,&nbsp;Abdul Aleem Memon ,&nbsp;Laveet Kumar ,&nbsp;Mohamed M. Awad","doi":"10.1016/j.nexus.2024.100291","DOIUrl":null,"url":null,"abstract":"<div><p>The air conditioning and refrigeration applications use a significant portion of the electrical energy. This research analyses a performance of refrigeration system, which comprises on different configurations of solar based organic Rankine cycle (ORC) and vapor compression refrigeration (VCR) cycles requiring low evaporation temperatures. In this research, the dry natural hydrocarbons such as n-Decane, n-Dodecane and Toluene have been chosen to serve as the working fluids in ORC. Whereas in VCR cycle natural hydrocarbons such as Ethane, Propane, isobutane, isopentane and isohexane have been used because traditional working fluids have a negative environmental impact due to high values of ozone depletion and global warming potential. The simulated results showed that the facility can be operated efficiently with the use solar thermal energy resources within the temperature range 90 to 315ºC and decreasing the need for conventional fossil fuel resources. It was also revealed that the highest efficiency was achieved by n-Dodecane in regenerative ORC, which is 35.34 % at the evaporation temperature of 315ºC and the highest overall coefficient of performance (<span><math><mrow><mtext>CO</mtext><msub><mi>P</mi><mtext>overall</mtext></msub><mrow><mo>)</mo></mrow></mrow></math></span> in regenerative ORC<img>CRS facility was achieved by n-Dodecane in ORC and isopentane in refrigeration cycle which is 1.017 while in case of Simple ORC–VCR facility the highest <span><math><mrow><mtext>CO</mtext><msub><mi>P</mi><mtext>overall</mtext></msub></mrow></math></span> was achieved by Toluene in ORC and isopentane in refrigeration cycle, which is 0.7174 at the evaporation temperature 315ºC.</p></div>","PeriodicalId":93548,"journal":{"name":"Energy nexus","volume":"14 ","pages":"Article 100291"},"PeriodicalIF":8.0000,"publicationDate":"2024-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772427124000226/pdfft?md5=07d768c691438fb0075910bfbf44c467&pid=1-s2.0-S2772427124000226-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy nexus","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772427124000226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

The air conditioning and refrigeration applications use a significant portion of the electrical energy. This research analyses a performance of refrigeration system, which comprises on different configurations of solar based organic Rankine cycle (ORC) and vapor compression refrigeration (VCR) cycles requiring low evaporation temperatures. In this research, the dry natural hydrocarbons such as n-Decane, n-Dodecane and Toluene have been chosen to serve as the working fluids in ORC. Whereas in VCR cycle natural hydrocarbons such as Ethane, Propane, isobutane, isopentane and isohexane have been used because traditional working fluids have a negative environmental impact due to high values of ozone depletion and global warming potential. The simulated results showed that the facility can be operated efficiently with the use solar thermal energy resources within the temperature range 90 to 315ºC and decreasing the need for conventional fossil fuel resources. It was also revealed that the highest efficiency was achieved by n-Dodecane in regenerative ORC, which is 35.34 % at the evaporation temperature of 315ºC and the highest overall coefficient of performance (COPoverall) in regenerative ORCCRS facility was achieved by n-Dodecane in ORC and isopentane in refrigeration cycle which is 1.017 while in case of Simple ORC–VCR facility the highest COPoverall was achieved by Toluene in ORC and isopentane in refrigeration cycle, which is 0.7174 at the evaporation temperature 315ºC.

基于太阳能的有机朗肯循环与蒸汽压缩制冷循环级联的热分析
空调和制冷应用需要消耗大量电能。本研究分析了制冷系统的性能,该系统包括不同配置的太阳能有机朗肯循环(ORC)和需要低蒸发温度的蒸汽压缩制冷(VCR)循环。在这项研究中,正癸烷、正十二烷和甲苯等干燥的天然碳氢化合物被选为有机郎肯循环的工作流体。而在 VCR 循环中则使用了天然碳氢化合物,如乙烷、丙烷、异丁烷、异戊烷和异己烷,因为传统的工作流体具有较高的臭氧消耗值和全球变暖潜能值,会对环境造成负面影响。模拟结果表明,在 90 至 315ºC 的温度范围内,利用太阳热能资源可以高效地运行设备,并减少对传统化石燃料资源的需求。模拟结果还显示,在再生式 ORC 中,正十二烷的效率最高,在蒸发温度为 315ºC 时达到 35.34%;在再生式 ORCCRS 设备中,ORC 中的正十二烷和制冷循环中的异戊烷的总体性能系数(COPoverall)最高,达到 1.017。而在简单 ORC-VCR 设备中,ORC 中的甲苯和制冷循环中的异戊烷在蒸发温度为 315ºC 时的 COPoverall 最高,为 0.7174。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Energy nexus
Energy nexus Energy (General), Ecological Modelling, Renewable Energy, Sustainability and the Environment, Water Science and Technology, Agricultural and Biological Sciences (General)
CiteScore
7.70
自引率
0.00%
发文量
0
审稿时长
109 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信