Comparison of Sleep and Physical Activity Metrics From Wrist-Worn ActiGraph wGT3X-BT and GT9X Accelerometers During Free-Living in Adults

Duncan S. Buchan
{"title":"Comparison of Sleep and Physical Activity Metrics From Wrist-Worn ActiGraph wGT3X-BT and GT9X Accelerometers During Free-Living in Adults","authors":"Duncan S. Buchan","doi":"10.1123/jmpb.2023-0026","DOIUrl":null,"url":null,"abstract":"Background: ActiGraph accelerometers can monitor sleep and physical activity (PA) during free-living, but there is a need to confirm agreement in outcomes between different models. Methods: Sleep and PA metrics from two ActiGraphs were compared after participants (N = 30) wore a GT9X and wGT3X-BT on their nondominant wrist for 7 days during free-living. PA metrics including total steps, counts, average acceleration—Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation, intensity gradient, the minimum acceleration value of the most active 10 and 30 min (M10, M30), time spent in activity intensities from vector magnitude (VM) counts, and ENMO cut points and sleep metrics (sleep period time window, sleep duration, sleep onset, and waking time) were compared. Results: Excellent agreement was evident for average acceleration-Mean Amplitude Deviation, counts, total steps, M10, and light PA (VM counts) with good agreement evident from the remaining PA metrics apart from moderate–vigorous PA (VM counts) which demonstrated moderate agreement. Mean bias for all PA metrics were low, as were the limits of agreement for the intensity gradient, average acceleration-Mean Amplitude Deviation, and inactive time (ENMO and VM counts). The limits of agreement for all other PA metrics were >10%. Excellent agreement, low mean bias, and narrow limits of agreement were evident for all sleep metrics. All sleep and PA metrics demonstrated equivalence (equivalence zone of ≤10%) apart from moderate–vigorous PA (ENMO) which needed an equivalence zone of 16%. Conclusions: Equivalent estimates of almost all PA and sleep metrics are provided from the GT9X and wGT3X-BT worn on the nondominant wrist.","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal for the measurement of physical behaviour","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1123/jmpb.2023-0026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: ActiGraph accelerometers can monitor sleep and physical activity (PA) during free-living, but there is a need to confirm agreement in outcomes between different models. Methods: Sleep and PA metrics from two ActiGraphs were compared after participants (N = 30) wore a GT9X and wGT3X-BT on their nondominant wrist for 7 days during free-living. PA metrics including total steps, counts, average acceleration—Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation, intensity gradient, the minimum acceleration value of the most active 10 and 30 min (M10, M30), time spent in activity intensities from vector magnitude (VM) counts, and ENMO cut points and sleep metrics (sleep period time window, sleep duration, sleep onset, and waking time) were compared. Results: Excellent agreement was evident for average acceleration-Mean Amplitude Deviation, counts, total steps, M10, and light PA (VM counts) with good agreement evident from the remaining PA metrics apart from moderate–vigorous PA (VM counts) which demonstrated moderate agreement. Mean bias for all PA metrics were low, as were the limits of agreement for the intensity gradient, average acceleration-Mean Amplitude Deviation, and inactive time (ENMO and VM counts). The limits of agreement for all other PA metrics were >10%. Excellent agreement, low mean bias, and narrow limits of agreement were evident for all sleep metrics. All sleep and PA metrics demonstrated equivalence (equivalence zone of ≤10%) apart from moderate–vigorous PA (ENMO) which needed an equivalence zone of 16%. Conclusions: Equivalent estimates of almost all PA and sleep metrics are provided from the GT9X and wGT3X-BT worn on the nondominant wrist.
比较腕戴式 ActiGraph wGT3X-BT 和 GT9X 加速计在成人自由生活期间测量的睡眠和体力活动指标
背景:ActiGraph 加速度计可监测自由生活期间的睡眠和体力活动(PA),但需要确认不同型号之间的结果是否一致。方法: 对两种 ActiGraph 的睡眠和体力活动指标进行比较:参与者(N = 30)在自由生活期间的非支配手腕上佩戴 GT9X 和 wGT3X-BT 7 天后,比较了两种 ActiGraph 的睡眠和体力活动指标。比较了包括总步数、计数、平均加速度-欧氏负一(ENMO)和平均振幅偏差、强度梯度、最活跃的 10 分钟和 30 分钟(M10、M30)的最小加速度值、矢量幅度(VM)计数的活动强度时间、ENMO 切点在内的 PA 指标和睡眠指标(睡眠期时间窗、睡眠持续时间、睡眠开始时间和觉醒时间)。结果显示平均加速度-平均振幅偏差、计数、总步数、M10 和轻度 PA(VM 计数)的一致性非常好,除中度-剧烈 PA(VM 计数)的一致性一般外,其余 PA 指标的一致性也很好。所有 PA 指标的平均偏差都很低,强度梯度、平均加速度-平均振幅偏差和非活动时间(ENMO 和 VM 计数)的一致性限度也很低。所有其他 PA 指标的一致性均大于 10%。所有睡眠指标的一致性都非常好,平均偏差小,一致性范围窄。除了中度剧烈运动(ENMO)需要 16% 的等效区域外,所有睡眠和剧烈运动指标均显示出等效性(等效区域≤10%)。结论佩戴在非支配腕上的 GT9X 和 wGT3X-BT 可以提供几乎所有 PA 和睡眠指标的等效估计值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信