The Potential Of Avocado Seed Extract (Persea Americana) In Inhibiting The Release Of Metal Ions In Cuniti And Stainless Steel Based Orthodont Wire

Leliana Sandra Devi, Dwi Prijatmoko, Rudy Joelijanto, Swasthi Prasetyarini, Herniyati, F. A. Soesetijo, Rina Sutjiati, Aura Sekar Asmarani Subagyo, Erlangga Bayu Mustika Aji
{"title":"The Potential Of Avocado Seed Extract (Persea Americana) In Inhibiting The Release Of Metal Ions In Cuniti And Stainless Steel Based Orthodont Wire","authors":"Leliana Sandra Devi, Dwi Prijatmoko, Rudy Joelijanto, Swasthi Prasetyarini, Herniyati, F. A. Soesetijo, Rina Sutjiati, Aura Sekar Asmarani Subagyo, Erlangga Bayu Mustika Aji","doi":"10.51601/ijhp.v4i2.322","DOIUrl":null,"url":null,"abstract":"The release of ions is the initial stage of the corrosion process in an orthodontic wire. Continuous release of ions can reduce the effectiveness and performance of the orthodontic wire. Continuous release of ions in CuNiTi orthodontic wire can change the properties of the wire and trigger hypersensitivity reactions, also in stainless steel orthodontic wire which experiences continuous release of ions can reduce its stiffness. The tannin in avocado seeds is useful as a corrosion inhibitor it can inhibit the release of ions because they are able to bind with metal ions and form a passive layer also able to bind with Fe ions in stainless steel orthodontic wires to form a passive surface layer which is able to inhibit the release of ions when the corrosion process occurs. The aim of this research is to determine the effect of avocado seed extract as a corrosion inhibitor on the release of metal ions from CuNiTi and stainless steel orthodontic wires. Rectangular CuNiTi and stainless steel orthodontic wires measuring 0.017 x 0.025 inches were taken in 3 groups (1 control group soaked in artificial saliva and 2 treatment groups soaked in avocado seed extract). The samples were soaked in avocado seed extract with a concentration of 1.5 g/L and 2 g/L for 7 days. To see the release of ions, an X-Ray Fluorescence test is carried out. In CuNiTi orthodontic wire from the one way ANOVA test showed that there was a significant difference between the control group and all treatment groups on Cu, Ni and Ti ions. The Post Hoc LSD test showed that there were significant differences between the control group, treatment group 1 and treatment group 2 in Cu, Ni and Ti ions with a p value. In stainless steel orthodontic wire, the one way ANOVA test showed that there was a significant difference between the control group and all treatment groups in Fe and Ni ions but not significant in Cr ions in the ion release test with a p value <0.05. The Post Hoc LSD test showed that there were significant differences between the control group, treatment group 1 and treatment group 2 in Fe and Ni ions with a p value <0.05. Providing avocado seed extract with tannin content at concentrations of 1.5 g/L and 2 g/L can inhibit the rate of ion release in CuNiTi and stainless steel orthodontic wires due to the corrosion process.","PeriodicalId":432290,"journal":{"name":"International Journal of Health and Pharmaceutical (IJHP)","volume":"42 20","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Health and Pharmaceutical (IJHP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51601/ijhp.v4i2.322","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The release of ions is the initial stage of the corrosion process in an orthodontic wire. Continuous release of ions can reduce the effectiveness and performance of the orthodontic wire. Continuous release of ions in CuNiTi orthodontic wire can change the properties of the wire and trigger hypersensitivity reactions, also in stainless steel orthodontic wire which experiences continuous release of ions can reduce its stiffness. The tannin in avocado seeds is useful as a corrosion inhibitor it can inhibit the release of ions because they are able to bind with metal ions and form a passive layer also able to bind with Fe ions in stainless steel orthodontic wires to form a passive surface layer which is able to inhibit the release of ions when the corrosion process occurs. The aim of this research is to determine the effect of avocado seed extract as a corrosion inhibitor on the release of metal ions from CuNiTi and stainless steel orthodontic wires. Rectangular CuNiTi and stainless steel orthodontic wires measuring 0.017 x 0.025 inches were taken in 3 groups (1 control group soaked in artificial saliva and 2 treatment groups soaked in avocado seed extract). The samples were soaked in avocado seed extract with a concentration of 1.5 g/L and 2 g/L for 7 days. To see the release of ions, an X-Ray Fluorescence test is carried out. In CuNiTi orthodontic wire from the one way ANOVA test showed that there was a significant difference between the control group and all treatment groups on Cu, Ni and Ti ions. The Post Hoc LSD test showed that there were significant differences between the control group, treatment group 1 and treatment group 2 in Cu, Ni and Ti ions with a p value. In stainless steel orthodontic wire, the one way ANOVA test showed that there was a significant difference between the control group and all treatment groups in Fe and Ni ions but not significant in Cr ions in the ion release test with a p value <0.05. The Post Hoc LSD test showed that there were significant differences between the control group, treatment group 1 and treatment group 2 in Fe and Ni ions with a p value <0.05. Providing avocado seed extract with tannin content at concentrations of 1.5 g/L and 2 g/L can inhibit the rate of ion release in CuNiTi and stainless steel orthodontic wires due to the corrosion process.
鳄梨籽提取物(Persea Americana)抑制库尼蒂和不锈钢正畸钢丝中金属离子释放的潜力
离子的释放是正畸钢丝腐蚀过程的初始阶段。离子的持续释放会降低正畸钢丝的效果和性能。在铜镍钛正畸钢丝中,离子的持续释放会改变钢丝的性能,并引发过敏反应;在不锈钢正畸钢丝中,离子的持续释放也会降低其硬度。牛油果籽中的单宁酸是一种有用的腐蚀抑制剂,它能抑制离子的释放,因为它们能与金属离子结合并形成一个被动层,还能与不锈钢正畸钢丝中的铁离子结合形成一个被动表面层,从而在腐蚀过程发生时抑制离子的释放。本研究的目的是确定鳄梨籽提取物作为缓蚀剂对铜镍钛和不锈钢正畸钢丝释放金属离子的影响。将尺寸为 0.017 x 0.025 英寸的矩形钛铜和不锈钢正畸钢丝分成 3 组(1 组对照组浸泡在人工唾液中,2 组处理组浸泡在鳄梨籽提取物中)。样品分别在浓度为 1.5 克/升和 2 克/升的鳄梨籽提取物中浸泡 7 天。为了观察离子的释放情况,进行了 X 射线荧光测试。在 CuNiTi 正畸钢丝中,单向方差分析测试表明,对照组和所有处理组在 Cu、Ni 和 Ti 离子上都有显著差异。事后 LSD 检验表明,对照组、治疗组 1 和治疗组 2 在 Cu、Ni 和 Ti 离子上存在显著差异(P 值)。在不锈钢正畸钢丝中,单向方差分析检验表明,在离子释放检验中,对照组和所有处理组在铁离子和镍离子方面存在显著差异,但在铬离子方面没有显著差异,P 值小于 0.05。事后 LSD 检验表明,对照组、处理组 1 和处理组 2 在铁离子和镍离子方面存在显著差异,P 值小于 0.05。提供浓度为 1.5 克/升和 2 克/升的含单宁酸的鳄梨籽提取物可抑制铜镍钛和不锈钢正畸钢丝因腐蚀过程而导致的离子释放速度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信