Perla Ganesh, CH. B. V. Narasimha Raju, N. Jagadeesh, Hemant M. Gandhi, BM. Rao, Dharamasoth Rama Devi, K. Basavaiah
{"title":"Trace level Determination of 2-(3-(trifluoromethyl)phenyl)propanal in Calcium Sensing Receptor drug by GCMS","authors":"Perla Ganesh, CH. B. V. Narasimha Raju, N. Jagadeesh, Hemant M. Gandhi, BM. Rao, Dharamasoth Rama Devi, K. Basavaiah","doi":"10.52711/0974-4150.2024.00005","DOIUrl":null,"url":null,"abstract":"The study aimed to develop and validate the method for trace level analysis of 2-(3-(trifluoromethyl)phenyl)propanal (2-TFL) impurity in calcium sensing receptor drugs by gas chromatographic method using mass spectrometry (GC-MS). The method utilizes a capillary column with 6% cyanopropyl phenyl and 94% dimethylpolysiloxane stationary phase with EI source in Selective Ion Monitoring (SIM) mode under programming temperature was used. After successful development, the method was validated according to our in-house validation guidelines for trace level analysis. The method proved to be selective for 2-(3-(trifluoromethyl) phenyl)propanal impurity in drug substance. A dissolve and injection approach was adopted for sample introduction in a split mode. Methanol was used as a diluent. The calibration curves showed good linearity over the concentration range from 1.85 (LOQ to 5.56ppm (150%)) of the target concentration of 3 ppm. The correlation coefficient obtained was >0.999. A limit of detection (LOD) of about 0.56ppm was achieved and limit of quantitation (LOQ) of 1.85ppm was achieved for 2-(3-(trifluoromethyl)phenyl)propanal impurity, when the samples were prepared at 20mg/mL. While recovery proved to be 101.0% at Limit of quantification (LOQ) level, 102.1% at Target analytical level (TAL) and 98.1% at 150% of the TAL, demonstrate the absence of matrix effect.","PeriodicalId":8550,"journal":{"name":"Asian Journal of Research in Chemistry","volume":"101 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Research in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/0974-4150.2024.00005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The study aimed to develop and validate the method for trace level analysis of 2-(3-(trifluoromethyl)phenyl)propanal (2-TFL) impurity in calcium sensing receptor drugs by gas chromatographic method using mass spectrometry (GC-MS). The method utilizes a capillary column with 6% cyanopropyl phenyl and 94% dimethylpolysiloxane stationary phase with EI source in Selective Ion Monitoring (SIM) mode under programming temperature was used. After successful development, the method was validated according to our in-house validation guidelines for trace level analysis. The method proved to be selective for 2-(3-(trifluoromethyl) phenyl)propanal impurity in drug substance. A dissolve and injection approach was adopted for sample introduction in a split mode. Methanol was used as a diluent. The calibration curves showed good linearity over the concentration range from 1.85 (LOQ to 5.56ppm (150%)) of the target concentration of 3 ppm. The correlation coefficient obtained was >0.999. A limit of detection (LOD) of about 0.56ppm was achieved and limit of quantitation (LOQ) of 1.85ppm was achieved for 2-(3-(trifluoromethyl)phenyl)propanal impurity, when the samples were prepared at 20mg/mL. While recovery proved to be 101.0% at Limit of quantification (LOQ) level, 102.1% at Target analytical level (TAL) and 98.1% at 150% of the TAL, demonstrate the absence of matrix effect.