{"title":"Comparison of Cyclic Fatigue Resistance of Two Different Rotary NiTi Instruments (An In-Vitro Study)","authors":"Dalia Abd allah, mohamed Nagy, Tariq Yehia","doi":"10.21608/asdj.2023.216874.1180","DOIUrl":null,"url":null,"abstract":"Aim: The aim of this study was to compare the dynamic CFR of M3-ProGold instruments and Pepsi Gold instruments. Material and methods: Eighty files of size 25/.06 of M3 Pro Gold files and Pepsi Gold files (each n = 40) were evaluated for dynamic cyclic fatigue resistance inside two artificial stainless-steel canals with 2 different radii [(60̊ curvature, 3 and 5 mm curvature radii) at body temperature and immersed in distilled water at 37° ± 1°C. The NCF (number of cycles to failure) was documented. The data was analysed by the use of ANOVA and Tukey post hoc tests (P ≤ 0 .05). Results: The Pepsi Gold instruments had a significantly greater NCF than the M3 Pro Gold files in both canal radii at body temperature. Conclusion: Pepsi Gold instruments have higher CFR than M3 Pro Gold instruments.","PeriodicalId":505319,"journal":{"name":"Ain Shams Dental Journal","volume":"36 1‐2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ain Shams Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/asdj.2023.216874.1180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aim: The aim of this study was to compare the dynamic CFR of M3-ProGold instruments and Pepsi Gold instruments. Material and methods: Eighty files of size 25/.06 of M3 Pro Gold files and Pepsi Gold files (each n = 40) were evaluated for dynamic cyclic fatigue resistance inside two artificial stainless-steel canals with 2 different radii [(60̊ curvature, 3 and 5 mm curvature radii) at body temperature and immersed in distilled water at 37° ± 1°C. The NCF (number of cycles to failure) was documented. The data was analysed by the use of ANOVA and Tukey post hoc tests (P ≤ 0 .05). Results: The Pepsi Gold instruments had a significantly greater NCF than the M3 Pro Gold files in both canal radii at body temperature. Conclusion: Pepsi Gold instruments have higher CFR than M3 Pro Gold instruments.