Development of a Spectrophotometric Method to Assay Tetracycline Hydrochloride by Coupling with Diazotized p-Aminobenzoic Acid,: Application to Pharmaceutical Forms
{"title":"Development of a Spectrophotometric Method to Assay Tetracycline Hydrochloride by Coupling with Diazotized p-Aminobenzoic Acid,: Application to Pharmaceutical Forms","authors":"Rania Ibraheem, Salim A. Mohammed","doi":"10.33899/rjs.2024.182835","DOIUrl":null,"url":null,"abstract":"This work comprises developing a sensitive and precise spectrophotometric procedure to analyze tetracycline hydrochloride in the bulk and in the drug forms. In this method, p-aminobenzoic acid reagent was diazotized with an equimolar NaNO 2 (sodium nitrite) solution in the existence of HCl (hydrochloric acid) to produce corresponding diazonium salt subsequently coupling with tetracycline hydrochloride in a basic solution of NH 4 OH to produce a yellow azo dye which was water soluble and has a maximum absorption at 422 nm versus a reagent blank. Under optimal conditions, the linearity of Beer's law was estimated to cover the concentration range of 0.25-17.5 µ g/ml with an exceptional determination coefficient (R 2 = 0.9993) and molar absorptivity of 1.66×10 4 l/mol.cm. The calculated values of detection limit (LOD) and quantitation limit (LOQ) were equal to 0.012 and 0.040 µ g/ml, respectively. The values of error percentage and precision (RSD%) ranges were calculated and found in the range of -0.08% to 3.3% and 0.16% to 1.59%, respectively. The stoichiometry of the product was set up to be 1:1 tetracycline hydrochloride: diazotized p-aminobenzoic acid. The mentioned procedure has been utilized successfully to the evaluation of tetracycline hydrochloride in capsules and ointment.","PeriodicalId":20803,"journal":{"name":"Rafidain journal of science","volume":"14 10","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rafidain journal of science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33899/rjs.2024.182835","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This work comprises developing a sensitive and precise spectrophotometric procedure to analyze tetracycline hydrochloride in the bulk and in the drug forms. In this method, p-aminobenzoic acid reagent was diazotized with an equimolar NaNO 2 (sodium nitrite) solution in the existence of HCl (hydrochloric acid) to produce corresponding diazonium salt subsequently coupling with tetracycline hydrochloride in a basic solution of NH 4 OH to produce a yellow azo dye which was water soluble and has a maximum absorption at 422 nm versus a reagent blank. Under optimal conditions, the linearity of Beer's law was estimated to cover the concentration range of 0.25-17.5 µ g/ml with an exceptional determination coefficient (R 2 = 0.9993) and molar absorptivity of 1.66×10 4 l/mol.cm. The calculated values of detection limit (LOD) and quantitation limit (LOQ) were equal to 0.012 and 0.040 µ g/ml, respectively. The values of error percentage and precision (RSD%) ranges were calculated and found in the range of -0.08% to 3.3% and 0.16% to 1.59%, respectively. The stoichiometry of the product was set up to be 1:1 tetracycline hydrochloride: diazotized p-aminobenzoic acid. The mentioned procedure has been utilized successfully to the evaluation of tetracycline hydrochloride in capsules and ointment.