Investigation into the analysis method for assessing contact stress in joint prosthesis

Q3 Medicine
Weiling Cui , Xushu Zhang , Weiyi Chen , Ji Qiu
{"title":"Investigation into the analysis method for assessing contact stress in joint prosthesis","authors":"Weiling Cui ,&nbsp;Xushu Zhang ,&nbsp;Weiyi Chen ,&nbsp;Ji Qiu","doi":"10.1016/j.medntd.2024.100299","DOIUrl":null,"url":null,"abstract":"<div><p>Contact stress is the important cause of wear and failure of knee joint prostheses implanted in the human body during movement. The calculation of contact stress on joint prostheses is often inaccurate due to the deviation of joint position during activity. This paper proposes a correction method for contact stress based on finite element results. Firstly, the contact stress and contact radius between femoral and tibial prostheses of knee joint were calculated and analyzed by Hertz contact theory. Then, individualized finite element models based on the individualized geometry of the joint prosthesis and individualized loading were constructed, and the finite element contact stress was analyzed. The finite element results were calibrated utilizing the Hertz contact theory. Additionally, this study investigated the impact of three gait patterns (normal gait, medial thrust gait, and bouncing gait) on the contact stress experienced by the tibial insert. The research methods and results can provide ideas for theoretical analysis and finite element simulation of prosthetic joint contact, as well as offer theoretical support and analysis methods for evaluating the lifespan of prosthetic joints.</p></div>","PeriodicalId":33783,"journal":{"name":"Medicine in Novel Technology and Devices","volume":"22 ","pages":"Article 100299"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2590093524000158/pdfft?md5=a5d7f8bec5a2fcf56be09999ee5837c1&pid=1-s2.0-S2590093524000158-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine in Novel Technology and Devices","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590093524000158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Contact stress is the important cause of wear and failure of knee joint prostheses implanted in the human body during movement. The calculation of contact stress on joint prostheses is often inaccurate due to the deviation of joint position during activity. This paper proposes a correction method for contact stress based on finite element results. Firstly, the contact stress and contact radius between femoral and tibial prostheses of knee joint were calculated and analyzed by Hertz contact theory. Then, individualized finite element models based on the individualized geometry of the joint prosthesis and individualized loading were constructed, and the finite element contact stress was analyzed. The finite element results were calibrated utilizing the Hertz contact theory. Additionally, this study investigated the impact of three gait patterns (normal gait, medial thrust gait, and bouncing gait) on the contact stress experienced by the tibial insert. The research methods and results can provide ideas for theoretical analysis and finite element simulation of prosthetic joint contact, as well as offer theoretical support and analysis methods for evaluating the lifespan of prosthetic joints.

关节假体接触应力评估分析方法研究
接触应力是导致植入人体的膝关节假体在运动过程中磨损和失效的重要原因。由于活动时关节位置的偏差,关节假体接触应力的计算往往不准确。本文提出了一种基于有限元结果的接触应力修正方法。首先,利用赫兹接触理论计算并分析了膝关节股骨假体和胫骨假体之间的接触应力和接触半径。然后,根据关节假体的个性化几何形状和个性化载荷构建个性化有限元模型,并对有限元接触应力进行分析。利用赫兹接触理论对有限元结果进行了校准。此外,该研究还调查了三种步态(正常步态、内侧推力步态和弹跳步态)对胫骨假体接触应力的影响。研究方法和结果可为假肢关节接触的理论分析和有限元模拟提供思路,并为评估假肢关节寿命提供理论支持和分析方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medicine in Novel Technology and Devices
Medicine in Novel Technology and Devices Medicine-Medicine (miscellaneous)
CiteScore
3.00
自引率
0.00%
发文量
74
审稿时长
64 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信