Development of a dispersive liquid-liquid microextraction method for the evaluation of maternal-fetal exposure to cocaine employing human umbilical cord tissue.
Gabriela de Paula Meirelles, Jefferson Pereira E Silva, Beatriz Aparecida Passos Bismara Paranhos, Mauricio Yonamine
{"title":"Development of a dispersive liquid-liquid microextraction method for the evaluation of maternal-fetal exposure to cocaine employing human umbilical cord tissue.","authors":"Gabriela de Paula Meirelles, Jefferson Pereira E Silva, Beatriz Aparecida Passos Bismara Paranhos, Mauricio Yonamine","doi":"10.1093/jat/bkae025","DOIUrl":null,"url":null,"abstract":"<p><p>Illicit drug use is a serious and complex public health problem, not only due to the severity of the health damage but also to the social implications, such as marginalization and drug trafficking. Currently, cocaine (COC) is among the most abused drugs worldwide with about 22 million users. Drug abuse has also been found in women during the pregnancy period, which has shed light on a new group for epidemiology. The diagnosis of COC use in these cases usually depends largely on the mother's reports, which in several cases omit or deny consumption. Therefore, considering physical-chemical methods of sample preparation and exposure biomarkers, the development of analytic toxicological methods can help to confirm drug use during pregnancy. Thus, the objective of the present work was to develop an analytical method based on dispersive liquid-liquid microextraction for the determination of COC analytes, using umbilical cord tissue as an alternative biological matrix, and detection by gas chromatography coupled to mass spectrometry. Therefore, after optimization, the dispersive liquid-liquid microextraction method was fully validated for quantification of COC, benzoylecgonine, cocaethylene, ecgonine, ecgonine methyl ester and norcocaine. The limits of detection were between 15 and 25 ng/g, the limits of quantification were 30 ng/g for ecgonine and 25 ng/g for the other analytes. Linearity ranged from the limits of quantification to 1,000 ng/g. Coefficients of variation for intra-assay precision were <18.5%, inter-assay was <8.75% and bias was <16.4% for all controls. The developed method was applied in 10 suspected positive samples, based on the mother's report and maternal urine screening and confirmation. COC, benzoylecgonine, ecgonine and ecgonine methyl ester were quantified in four umbilical cords with concentrations that ranged from 39.6 to 420.5 ng/g.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":"263-272"},"PeriodicalIF":2.3000,"publicationDate":"2024-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkae025","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Illicit drug use is a serious and complex public health problem, not only due to the severity of the health damage but also to the social implications, such as marginalization and drug trafficking. Currently, cocaine (COC) is among the most abused drugs worldwide with about 22 million users. Drug abuse has also been found in women during the pregnancy period, which has shed light on a new group for epidemiology. The diagnosis of COC use in these cases usually depends largely on the mother's reports, which in several cases omit or deny consumption. Therefore, considering physical-chemical methods of sample preparation and exposure biomarkers, the development of analytic toxicological methods can help to confirm drug use during pregnancy. Thus, the objective of the present work was to develop an analytical method based on dispersive liquid-liquid microextraction for the determination of COC analytes, using umbilical cord tissue as an alternative biological matrix, and detection by gas chromatography coupled to mass spectrometry. Therefore, after optimization, the dispersive liquid-liquid microextraction method was fully validated for quantification of COC, benzoylecgonine, cocaethylene, ecgonine, ecgonine methyl ester and norcocaine. The limits of detection were between 15 and 25 ng/g, the limits of quantification were 30 ng/g for ecgonine and 25 ng/g for the other analytes. Linearity ranged from the limits of quantification to 1,000 ng/g. Coefficients of variation for intra-assay precision were <18.5%, inter-assay was <8.75% and bias was <16.4% for all controls. The developed method was applied in 10 suspected positive samples, based on the mother's report and maternal urine screening and confirmation. COC, benzoylecgonine, ecgonine and ecgonine methyl ester were quantified in four umbilical cords with concentrations that ranged from 39.6 to 420.5 ng/g.
期刊介绍:
The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation.
Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.