{"title":"[Ion chromatography for the determination of n-butylamine in the workplace air].","authors":"L Chen, Y P Liu, L Yang, H F Yan","doi":"10.3760/cma.j.cn121094-20221111-00540","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To establish a method for the determination of n-butylamine in the air of the workplace by ion chromatography. <b>Methods:</b> In February 2022, on-site sampling was carried out using an atmospheric sampler. N-butylamine was adsorbed by a neutral silica gel tube and then performed for qualitative and quantitative determination by ion chromatography after ultrasonic desorption with 10 mmol/L sulfuric acid solution. <b>Results:</b> The linear range of the method was 0.0375-100.0 μg/ml, the linear equation of the standard curve was <i>y</i>=0.0713<i>x</i>-0.0327, the correlation coefficient was 0.9992. The detection limit of the method was 11.25 μg/L, and the lower limit of quantification was 37.50 μg/L, the lowest quantitative concentration was 0.025 mg/m(3) (in term of sampling 7.5 L). The average desorption efficiency of the method was 91.50%-95.38%, the precision was 1.10%-2.30%, the standard recovery was 83.83%-100.02%, sampling efficiency was 100.00%. <b>Conclusion:</b> This method is fast, sensitive and accurate, and can be used for the determination of n-butylamine in the air of workplace.</p>","PeriodicalId":23958,"journal":{"name":"中华劳动卫生职业病杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华劳动卫生职业病杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121094-20221111-00540","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To establish a method for the determination of n-butylamine in the air of the workplace by ion chromatography. Methods: In February 2022, on-site sampling was carried out using an atmospheric sampler. N-butylamine was adsorbed by a neutral silica gel tube and then performed for qualitative and quantitative determination by ion chromatography after ultrasonic desorption with 10 mmol/L sulfuric acid solution. Results: The linear range of the method was 0.0375-100.0 μg/ml, the linear equation of the standard curve was y=0.0713x-0.0327, the correlation coefficient was 0.9992. The detection limit of the method was 11.25 μg/L, and the lower limit of quantification was 37.50 μg/L, the lowest quantitative concentration was 0.025 mg/m(3) (in term of sampling 7.5 L). The average desorption efficiency of the method was 91.50%-95.38%, the precision was 1.10%-2.30%, the standard recovery was 83.83%-100.02%, sampling efficiency was 100.00%. Conclusion: This method is fast, sensitive and accurate, and can be used for the determination of n-butylamine in the air of workplace.