Longitudinal bond strength of a universal adhesive and chemical dentin characterization under different acid etching protocols.

IF 2.2 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Applied Oral Science Pub Date : 2024-03-22 eCollection Date: 2024-01-01 DOI:10.1590/1678-7757-2023-0359
Lucélia Lemes Gonçalves, Anuradha Prakki, Tânia Mara da Silva, Arwa Bafail, Janaína Bortolatto, Alexander Terry Stavroullakis, Sérgio Eduardo de Paiva Gonçalves
{"title":"Longitudinal bond strength of a universal adhesive and chemical dentin characterization under different acid etching protocols.","authors":"Lucélia Lemes Gonçalves, Anuradha Prakki, Tânia Mara da Silva, Arwa Bafail, Janaína Bortolatto, Alexander Terry Stavroullakis, Sérgio Eduardo de Paiva Gonçalves","doi":"10.1590/1678-7757-2023-0359","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to analyze the longitudinal bond strength of a universal adhesive and chemically characterize the dentin substrate under different acid etching protocols.</p><p><strong>Methodology: </strong>Dentin samples were etched with polyacrylic acid 25% (PAA) for 10 seconds (n=3) and phosphoric acid 32% (PA) for 15 seconds (n=3) and analyzed by Fourier transform infrared spectroscopy - attenuated total reflectance (FTIR-ATR) before and after treatment. For collagen degradation, samples (n=12) were divided into 3 groups: PAA, PA, and Deionized water (control), and analyzed by the quantity of solubilized type I collagen C-terminal cross-linked telopeptides and solubilized C-terminal peptide in relation to total protein concentration (ICTPtp and CTXtp) and by their ultimate tensile strength (UTS). For the adhesive interface analysis, dentin samples (n=72) were divided into 3 groups: PAA, PA, and Self-etch (SE), and subdivided into 2 groups: 24 h (baseline) and 1 year. The following tests were performed: microtensile bond strength (μTBS) (n=48), scanning electron microscopy (SEM) (n=12), and nanoleakage (n=12).</p><p><strong>Results: </strong>The FTIR of PAA showed lower reduction of the peaks in the phosphate group when compared to PA. For ICTPtp, PA showed a significantly higher value. For CTXtp, PA and PAA groups failed to statically differ from each other. UTS was significantly lower for PA. For μTBS, storage time significantly affected bond strength. The results were unaffected by the etching protocol. For SEM, after 1 year, PA had little evidence of degradation in the upper third of the adhesive interface in comparison to the other groups. Nanoleakage showed no considerable silver impregnation after 1 year in the SE group.</p><p><strong>Conclusion: </strong>The use of PAA prior to a universal adhesive (when compared to PA) represents a less aggressive type of etching to dentin. However, self-etching still seems to be the best option for universal adhesive systems that have functional monomers in their composition.</p>","PeriodicalId":15133,"journal":{"name":"Journal of Applied Oral Science","volume":"32 ","pages":"e20230359"},"PeriodicalIF":2.2000,"publicationDate":"2024-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11037927/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Oral Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1678-7757-2023-0359","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study aimed to analyze the longitudinal bond strength of a universal adhesive and chemically characterize the dentin substrate under different acid etching protocols.

Methodology: Dentin samples were etched with polyacrylic acid 25% (PAA) for 10 seconds (n=3) and phosphoric acid 32% (PA) for 15 seconds (n=3) and analyzed by Fourier transform infrared spectroscopy - attenuated total reflectance (FTIR-ATR) before and after treatment. For collagen degradation, samples (n=12) were divided into 3 groups: PAA, PA, and Deionized water (control), and analyzed by the quantity of solubilized type I collagen C-terminal cross-linked telopeptides and solubilized C-terminal peptide in relation to total protein concentration (ICTPtp and CTXtp) and by their ultimate tensile strength (UTS). For the adhesive interface analysis, dentin samples (n=72) were divided into 3 groups: PAA, PA, and Self-etch (SE), and subdivided into 2 groups: 24 h (baseline) and 1 year. The following tests were performed: microtensile bond strength (μTBS) (n=48), scanning electron microscopy (SEM) (n=12), and nanoleakage (n=12).

Results: The FTIR of PAA showed lower reduction of the peaks in the phosphate group when compared to PA. For ICTPtp, PA showed a significantly higher value. For CTXtp, PA and PAA groups failed to statically differ from each other. UTS was significantly lower for PA. For μTBS, storage time significantly affected bond strength. The results were unaffected by the etching protocol. For SEM, after 1 year, PA had little evidence of degradation in the upper third of the adhesive interface in comparison to the other groups. Nanoleakage showed no considerable silver impregnation after 1 year in the SE group.

Conclusion: The use of PAA prior to a universal adhesive (when compared to PA) represents a less aggressive type of etching to dentin. However, self-etching still seems to be the best option for universal adhesive systems that have functional monomers in their composition.

不同酸蚀方案下通用粘合剂的纵向粘接强度和化学牙本质表征。
研究目的本研究旨在分析通用粘合剂的纵向粘接强度,以及不同酸蚀方案下牙本质基底的化学特征:用聚丙烯酸 25% (PAA) 酸蚀牙本质样本 10 秒(n=3),用磷酸 32% (PA) 酸蚀牙本质样本 15 秒(n=3),并在处理前后用傅立叶变换红外光谱-衰减全反射(FTIR-ATR)进行分析。胶原降解样本(n=12)分为 3 组:分析溶解的 I 型胶原 C 端交联端肽和溶解的 C 端肽的数量与总蛋白质浓度的关系(ICTPtp 和 CTXtp)以及它们的极限拉伸强度(UTS)。在粘接界面分析中,牙本质样本(n=72)被分为 3 组:PAA、PA 和自酸蚀 (SE),并细分为 2 组:24 小时(基线)和 1 年。进行了以下测试:微拉伸粘接强度(μTBS)(n=48)、扫描电子显微镜(SEM)(n=12)和纳米渗漏(n=12):与 PA 相比,PAA 的傅立叶变换红外光谱显示磷酸基团的峰值减少较少。对于 ICTPtp,PA 的值明显更高。在 CTXtp 中,PA 和 PAA 组之间没有统计学差异。PA 的 UTS 值明显较低。对于 μTBS 而言,储存时间对粘接强度有显著影响。蚀刻方案对结果没有影响。就扫描电子显微镜(SEM)而言,1 年后,与其他组别相比,PA 在粘合界面上部三分之一处几乎没有降解的迹象。纳米渗漏显示,SE 组在 1 年后没有明显的银浸渍:结论:在使用通用粘接剂之前使用 PAA(与 PA 相比)是一种对牙本质侵蚀性较小的蚀刻方式。然而,对于成分中含有功能性单体的通用粘合剂系统来说,自酸蚀似乎仍然是最佳选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Oral Science
Journal of Applied Oral Science 医学-牙科与口腔外科
CiteScore
4.80
自引率
3.70%
发文量
46
审稿时长
4-8 weeks
期刊介绍: The Journal of Applied Oral Science is committed in publishing the scientific and technologic advances achieved by the dental community, according to the quality indicators and peer reviewed material, with the objective of assuring its acceptability at the local, regional, national and international levels. The primary goal of The Journal of Applied Oral Science is to publish the outcomes of original investigations as well as invited case reports and invited reviews in the field of Dentistry and related areas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信