Virtual Transmission Solution Based on Battery Energy Storage Systems to Boost Transmission Capacity

IF 5.7 1区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Matías Agüero;Jaime Peralta;Eugenio Quintana;Victor Velar;Anton Stepanov;Hossein Ashourian;Jean Mahseredjian;Roberto Cárdenas
{"title":"Virtual Transmission Solution Based on Battery Energy Storage Systems to Boost Transmission Capacity","authors":"Matías Agüero;Jaime Peralta;Eugenio Quintana;Victor Velar;Anton Stepanov;Hossein Ashourian;Jean Mahseredjian;Roberto Cárdenas","doi":"10.35833/MPCE.2023.000729","DOIUrl":null,"url":null,"abstract":"The increasing penetration of variable renewable energy (VRE) generation along with the decommissioning of conventional power plants in Chile, has raised several operational challenges in the Chilean National Power Grid (NPG), including transmission congestion and VRE curtailment. To mitigate these limitations, an innovative virtual transmission solution based on battery energy storage systems (BESSs), known as grid booster (GB), has been proposed to increase the capacity of the main 500 kV corridor of the NPG. This paper analyzes the dynamic performance of the GB using a wide-area electromagnetic transient (EMT) model of the NPG. The GB project, composed of two 500 MVA BESS units at each extreme of the 500 kV corridor, allows increasing the transmission capacity for 15 min during N-1 contingencies, overcoming transmission limitations under normal operation conditions while maintaining system stability during faults. The dynamic behavior of the GB is also analyzed to control power flow as well as voltage stability. The results show that the GB is an effective solution to allow greater penetration of VRE generation while maintaining system stability in the NPG.","PeriodicalId":51326,"journal":{"name":"Journal of Modern Power Systems and Clean Energy","volume":"12 2","pages":"466-474"},"PeriodicalIF":5.7000,"publicationDate":"2024-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10478441","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Modern Power Systems and Clean Energy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10478441/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The increasing penetration of variable renewable energy (VRE) generation along with the decommissioning of conventional power plants in Chile, has raised several operational challenges in the Chilean National Power Grid (NPG), including transmission congestion and VRE curtailment. To mitigate these limitations, an innovative virtual transmission solution based on battery energy storage systems (BESSs), known as grid booster (GB), has been proposed to increase the capacity of the main 500 kV corridor of the NPG. This paper analyzes the dynamic performance of the GB using a wide-area electromagnetic transient (EMT) model of the NPG. The GB project, composed of two 500 MVA BESS units at each extreme of the 500 kV corridor, allows increasing the transmission capacity for 15 min during N-1 contingencies, overcoming transmission limitations under normal operation conditions while maintaining system stability during faults. The dynamic behavior of the GB is also analyzed to control power flow as well as voltage stability. The results show that the GB is an effective solution to allow greater penetration of VRE generation while maintaining system stability in the NPG.
基于电池储能系统的虚拟输电解决方案提升输电能力
随着智利可再生能源(VRE)发电渗透率的不断提高以及传统发电厂的退役,智利国家电网(NPG)面临着一些运营挑战,包括输电拥堵和可再生能源削减。为了缓解这些限制,有人提出了一种基于电池储能系统(BESS)的创新型虚拟输电解决方案,即电网升压器(GB),以提高国家电网 500 千伏主通道的容量。本文利用 NPG 的广域电磁暂态 (EMT) 模型分析了 GB 的动态性能。GB 项目由位于 500 千伏走廊两端的两个 500 兆伏安 BESS 单元组成,可在 N-1 突发事件期间将输电容量提高 15 分钟,克服正常运行条件下的输电限制,同时在故障期间保持系统稳定。此外,还对 GB 的动态行为进行了分析,以控制功率流和电压稳定性。结果表明,GB 是一种有效的解决方案,既能提高 VRE 发电的渗透率,又能保持 NPG 的系统稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Modern Power Systems and Clean Energy
Journal of Modern Power Systems and Clean Energy ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
12.30
自引率
14.30%
发文量
97
审稿时长
13 weeks
期刊介绍: Journal of Modern Power Systems and Clean Energy (MPCE), commencing from June, 2013, is a newly established, peer-reviewed and quarterly published journal in English. It is the first international power engineering journal originated in mainland China. MPCE publishes original papers, short letters and review articles in the field of modern power systems with focus on smart grid technology and renewable energy integration, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信