Determining the Optimum Pressure Differential Across the Control Valve of a Hydroturbine Driven Pump

IF 0.9 Q4 ENERGY & FUELS
A. V. Popov, E. N. Kulakov, P. A. Kruglikov, F. A. Svyatkin, P. G. Pavlov, R. S. Tarasenko, I. B. Denisova, A. V. Proukhin
{"title":"Determining the Optimum Pressure Differential Across the Control Valve of a Hydroturbine Driven Pump","authors":"A. V. Popov,&nbsp;E. N. Kulakov,&nbsp;P. A. Kruglikov,&nbsp;F. A. Svyatkin,&nbsp;P. G. Pavlov,&nbsp;R. S. Tarasenko,&nbsp;I. B. Denisova,&nbsp;A. V. Proukhin","doi":"10.1134/S0040601524020071","DOIUrl":null,"url":null,"abstract":"<p>When using lead as a primary circuit coolant, certain difficulties arise not only from the side of the reactor plant (structural materials, fuel, etc.) but also from the side of the steam turbine cycle. A feature of the second circuit of a lead-cooled NPP is noted, such as the need to maintain a high temperature of the feedwater in front of the steam generator, caused by its melting/freezing temperature. For the pilot demonstration power unit with the BREST-OD-300 reactor plant, it was decided to use a mixing feedwater heater, which entailed the appearance of a second rise in the feed pump circuit. Due to the lack of electric drive pumps for such high parameters, it was proposed to use a hydraulic turbine driven pump as a feed pump behind the mixing feedwater heater. These pumps have a significant impact on efficiency due to the multistage energy conversion, and there is no recommendation for selecting resistance on the control valve of these pumps. A computational study was carried out to determine the optimal pressure drop on the control valve of the hydraulic turbine drive of the feed pump of the power unit with the BREST-OD-300 reactor plant. Optimal is understood as the ultimate minimum differential at which the valve is able to carry out regulation with specified quality criteria and ensure the lowest energy consumption for its own needs. Recommendations are given for choosing the optimal pressure drop on the control valve of the hydraulic turbine drive of the feed pump of a turbine unit with the BREST-OD-300 reactor. A methodology has been developed for solving problems of optimizing pressure drop in units of complex hydraulic systems.</p>","PeriodicalId":799,"journal":{"name":"Thermal Engineering","volume":"71 2","pages":"118 - 124"},"PeriodicalIF":0.9000,"publicationDate":"2024-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thermal Engineering","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1134/S0040601524020071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

When using lead as a primary circuit coolant, certain difficulties arise not only from the side of the reactor plant (structural materials, fuel, etc.) but also from the side of the steam turbine cycle. A feature of the second circuit of a lead-cooled NPP is noted, such as the need to maintain a high temperature of the feedwater in front of the steam generator, caused by its melting/freezing temperature. For the pilot demonstration power unit with the BREST-OD-300 reactor plant, it was decided to use a mixing feedwater heater, which entailed the appearance of a second rise in the feed pump circuit. Due to the lack of electric drive pumps for such high parameters, it was proposed to use a hydraulic turbine driven pump as a feed pump behind the mixing feedwater heater. These pumps have a significant impact on efficiency due to the multistage energy conversion, and there is no recommendation for selecting resistance on the control valve of these pumps. A computational study was carried out to determine the optimal pressure drop on the control valve of the hydraulic turbine drive of the feed pump of the power unit with the BREST-OD-300 reactor plant. Optimal is understood as the ultimate minimum differential at which the valve is able to carry out regulation with specified quality criteria and ensure the lowest energy consumption for its own needs. Recommendations are given for choosing the optimal pressure drop on the control valve of the hydraulic turbine drive of the feed pump of a turbine unit with the BREST-OD-300 reactor. A methodology has been developed for solving problems of optimizing pressure drop in units of complex hydraulic systems.

Abstract Image

Abstract Image

确定水轮机驱动泵控制阀上的最佳压差
摘要当使用铅作为一回路冷却剂时,不仅会在反应堆厂房(结构材料、燃料等)方面产生一些困难,而且还会在蒸汽轮机循环方面产生一些困难。我们注意到铅冷核电站二回路的一个特点,如蒸汽发生器前的给水需要保持较高的温度,这是由其熔化/冻结温度引起的。在 BREST-OD-300 反应堆厂房的试验示范动力装置中,决定使用混合给水加热器,这就需要在给水泵回路中再增加一个加热器。由于缺乏适用于如此高参数的电力驱动泵,因此建议在混合给水加热器后面使用水轮机驱动泵作为给水泵。由于多级能量转换,这些泵对效率有很大影响,而且没有关于选择这些泵控制阀阻力的建议。我们进行了一项计算研究,以确定 BREST-OD-300 反应堆发电装置给水泵水轮机驱动控制阀的最佳压降。最佳压差被理解为阀门能够按照规定的质量标准进行调节并确保自身需要的最低能耗的最终最小压差。建议如何选择 BREST-OD-300 反应堆汽轮机组进料泵水轮机驱动控制阀的最佳压降。为解决复杂液压系统机组压降优化问题开发了一种方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.30
自引率
20.00%
发文量
94
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信