Flexural strength of repaired denture base materials manufactured for the CAD-CAM technique.

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of oral science Pub Date : 2024-04-16 Epub Date: 2024-03-15 DOI:10.2334/josnusd.23-0275
Şebnem Özatik, Canan Bural Alan
{"title":"Flexural strength of repaired denture base materials manufactured for the CAD-CAM technique.","authors":"Şebnem Özatik, Canan Bural Alan","doi":"10.2334/josnusd.23-0275","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the flexural properties of repaired poly(methylmethacrylate) (PMMA) denture base materials for computer-aided design/computer-aided manufacturing (CAD-CAM) and to compare them with heat-activated polymerized PMMA.</p><p><strong>Methods: </strong>A total of 288 specimens (65 × 10 × 2.5 mm) were prepared using both CAD-CAM and conventional blocks and repaired using autopolymerizing and visible-light polymerizing (VLC) materials. Microwave energy, water storage and hydroflask polymerization were applied as additional post-polymerization cycles after the repair process. The flexural strength (FS) of the specimens was evaluated using the three-point bending test. Data were evaluated statistically using 2-way ANOVA followed by Bonferroni's correction to determine the significance of differences between the groups (P ≤ 0.05).</p><p><strong>Results: </strong>The FS of the denture base materials for CAD-CAM was significantly higher than that for the heat-activated group (P ≤ 0.05). The FS was significantly highest when microwave energy was used for the post-polymerization cycle. The FS values for all groups repaired with VLC resin were significantly lower than for the autopolymerization group (P ≤ 0.05).</p><p><strong>Conclusion: </strong>The flexural properties of denture base materials for CAD-CAM repaired using autopolymerizing acrylic resins can recover by 50-70%. Additional post-polymerization cycles for autopolymerizing repair resin can be suggested to improve the clinical service properties of repaired dentures.</p>","PeriodicalId":16646,"journal":{"name":"Journal of oral science","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2334/josnusd.23-0275","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the flexural properties of repaired poly(methylmethacrylate) (PMMA) denture base materials for computer-aided design/computer-aided manufacturing (CAD-CAM) and to compare them with heat-activated polymerized PMMA.

Methods: A total of 288 specimens (65 × 10 × 2.5 mm) were prepared using both CAD-CAM and conventional blocks and repaired using autopolymerizing and visible-light polymerizing (VLC) materials. Microwave energy, water storage and hydroflask polymerization were applied as additional post-polymerization cycles after the repair process. The flexural strength (FS) of the specimens was evaluated using the three-point bending test. Data were evaluated statistically using 2-way ANOVA followed by Bonferroni's correction to determine the significance of differences between the groups (P ≤ 0.05).

Results: The FS of the denture base materials for CAD-CAM was significantly higher than that for the heat-activated group (P ≤ 0.05). The FS was significantly highest when microwave energy was used for the post-polymerization cycle. The FS values for all groups repaired with VLC resin were significantly lower than for the autopolymerization group (P ≤ 0.05).

Conclusion: The flexural properties of denture base materials for CAD-CAM repaired using autopolymerizing acrylic resins can recover by 50-70%. Additional post-polymerization cycles for autopolymerizing repair resin can be suggested to improve the clinical service properties of repaired dentures.

采用 CAD-CAM 技术制造的修复义齿基托材料的抗弯强度。
目的:评估用于计算机辅助设计/计算机辅助制造(CAD-CAM)的修复聚甲基丙烯酸甲酯(PMMA)义齿基托材料的弯曲性能,并与热激活聚合的 PMMA 进行比较:使用 CAD-CAM 和传统砌块共制备了 288 个试样(65 × 10 × 2.5 毫米),并使用自动聚合和可见光聚合 (VLC) 材料进行了修复。修复过程结束后,还进行了微波能、蓄水和水槽聚合等后聚合循环。试样的抗弯强度(FS)采用三点弯曲试验进行评估。采用双因素方差分析对数据进行统计评估,然后进行 Bonferroni 校正,以确定组间差异的显著性(P ≤ 0.05):结果:CAD-CAM义齿基托材料的FS明显高于热激活组(P≤0.05)。在聚合后循环中使用微波能时,FS 值明显最高。用 VLC 树脂修复的所有组的 FS 值都明显低于自聚合组(P ≤ 0.05):结论:使用自聚合丙烯酸树脂修复的 CAD-CAM 义齿基托材料的弯曲性能可恢复 50-70%。建议对自动聚合修复树脂进行更多的聚合后循环,以改善修复义齿的临床使用性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of oral science
Journal of oral science DENTISTRY, ORAL SURGERY & MEDICINE-MATERIALS SCIENCE, BIOMATERIALS
CiteScore
3.80
自引率
0.00%
发文量
58
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信