Preheating and “snow-plow” composite application technique affect double bond conversion but not bond strength to dentine

IF 3.2 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Vesna Miletic BDS, MSc, PhD, Vojislav Komlenic DDS, PhD, Danica Bajuk-Bogdanović PhD, Jovana Stasic DDS, PhD, Violeta Petrovic BDS, MSc, PhD, Tatjana Savic-Stankovic BDS, MSc, PhD
{"title":"Preheating and “snow-plow” composite application technique affect double bond conversion but not bond strength to dentine","authors":"Vesna Miletic BDS, MSc, PhD,&nbsp;Vojislav Komlenic DDS, PhD,&nbsp;Danica Bajuk-Bogdanović PhD,&nbsp;Jovana Stasic DDS, PhD,&nbsp;Violeta Petrovic BDS, MSc, PhD,&nbsp;Tatjana Savic-Stankovic BDS, MSc, PhD","doi":"10.1111/jerd.13218","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>To measure degree of conversion (DC) of a flowable composite, microtensile bond strength (MTBS) to dentine in the snow-plow technique with/without preheating and temperature in the preheated composite.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>For DC, snow-plow specimens of Filtek Ultimate Flowable (Flow) and Filtek Bulk Fill (Bulk) (3M) were prepared by light-curing composites simultaneously in standardized molds while in control groups light-curing was separate. DC of Flow was measured using micro-Raman spectroscopy. For MTBS, specimens were prepared on dentine of human extracted molars by simultaneous (snow-plow) or separate (control) light-curing. MTBS was measured using a universal testing machine after 24 h and 6 months. Data were analyzed using ANOVA with Tukey's post hoc (<i>α</i> = 0.05).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Increased curing time significantly increased DC in snow-plow from 13.4% ± 11.6% (10 s) to 31.8% ± 4.4% (40 s) albeit significantly lower than controls (<i>p</i> &lt; 0.05). Preheated Bulk improved conversion in snow-plow (44.3% ± 1.7%) and control (50.5% ± 2.6%) (<i>p</i> &lt; 0.05). No significant differences occurred in MTBS between groups (<i>p</i> &gt; 0.05). MTBS values ranged between 66.7 ± 8.4 MPa (snow-plow group_21°C_baseline) and 54.1 ± 15.8 MPa (control_21°C_long-term). Temperature in the preheated Bulk dropped to ~38°C after 30 s.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Snow-plow technique, irrespective of preheating, resulted in lower DC of Flow than separate light-curing of composite increments. Snow-plow, irrespective of preheating, resulted in similar initial and long-term MTBS to dentine.</p>\n </section>\n \n <section>\n \n <h3> Clinical Significance</h3>\n \n <p>Clinicians with preference for flowable composite liners in Class II restorations should be aware that the snow-plow technique of simultaneous light-curing of flowable and bulk-fill composite increments affects monomer-to-polymer conversion, albeit no effect on immediate, and long-term bonding to dentine was detected. Preheating sculptable bulk-fill composite improves conversion of the flowable liner in the snow-plow technique but has no detectable effect on bond strength to dentine.</p>\n </section>\n </div>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13218","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To measure degree of conversion (DC) of a flowable composite, microtensile bond strength (MTBS) to dentine in the snow-plow technique with/without preheating and temperature in the preheated composite.

Materials and Methods

For DC, snow-plow specimens of Filtek Ultimate Flowable (Flow) and Filtek Bulk Fill (Bulk) (3M) were prepared by light-curing composites simultaneously in standardized molds while in control groups light-curing was separate. DC of Flow was measured using micro-Raman spectroscopy. For MTBS, specimens were prepared on dentine of human extracted molars by simultaneous (snow-plow) or separate (control) light-curing. MTBS was measured using a universal testing machine after 24 h and 6 months. Data were analyzed using ANOVA with Tukey's post hoc (α = 0.05).

Results

Increased curing time significantly increased DC in snow-plow from 13.4% ± 11.6% (10 s) to 31.8% ± 4.4% (40 s) albeit significantly lower than controls (p < 0.05). Preheated Bulk improved conversion in snow-plow (44.3% ± 1.7%) and control (50.5% ± 2.6%) (p < 0.05). No significant differences occurred in MTBS between groups (p > 0.05). MTBS values ranged between 66.7 ± 8.4 MPa (snow-plow group_21°C_baseline) and 54.1 ± 15.8 MPa (control_21°C_long-term). Temperature in the preheated Bulk dropped to ~38°C after 30 s.

Conclusions

Snow-plow technique, irrespective of preheating, resulted in lower DC of Flow than separate light-curing of composite increments. Snow-plow, irrespective of preheating, resulted in similar initial and long-term MTBS to dentine.

Clinical Significance

Clinicians with preference for flowable composite liners in Class II restorations should be aware that the snow-plow technique of simultaneous light-curing of flowable and bulk-fill composite increments affects monomer-to-polymer conversion, albeit no effect on immediate, and long-term bonding to dentine was detected. Preheating sculptable bulk-fill composite improves conversion of the flowable liner in the snow-plow technique but has no detectable effect on bond strength to dentine.

预热和 "雪犁式 "复合材料应用技术会影响双键转换,但不会影响与牙本质的粘接强度。
目的:测量可流动复合材料的转换度(DC)、雪犁技术中与牙本质的微张力粘接强度(MTBS)、预热/不预热以及预热复合材料的温度:对于直流电,Filtek Ultimate Flowable(Flow)和 Filtek Bulk Fill(Bulk)(3M)的雪犁试样是在标准模具中同时光固化复合材料制备的,而对照组的光固化是分开进行的。流体的直流电用微拉曼光谱法测量。对于 MTBS,在人类拔出的臼齿的牙本质上通过同时光固化(刨雪)或单独光固化(对照组)制备试样。分别在 24 小时和 6 个月后使用万能试验机测量 MTBS。采用方差分析和 Tukey 后验(α = 0.05)对数据进行分析:固化时间的延长明显增加了扫雪机的 DC,从 13.4% ± 11.6% (10 秒) 增加到 31.8% ± 4.4% (40 秒),尽管明显低于对照组 (p 0.05)。MTBS 值介于 66.7 ± 8.4 兆帕(扫雪机组_21°C_基准)和 54.1 ± 15.8 兆帕(对照组_21°C_长期)之间。预热块体的温度在 30 秒后降至约 38°C:结论:与复合材料增量的单独光固化相比,无论预热与否,扫雪技术都能产生较低的流动直流电。无论预热与否,雪犁技术与牙本质的初始和长期 MTBS 相似:临床意义:在二类修复体中偏爱使用可流动复合材料内衬的临床医生应该注意,同时光固化可流动和块状填充复合材料增量的 "雪犁 "技术会影响单体到聚合物的转化,尽管没有发现这种技术会影响与牙本质的即时和长期粘接。预热可雕刻散装填充复合材料可以提高雪犁技术中流动衬垫的转化率,但对与牙本质的粘接强度没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Esthetic and Restorative Dentistry
Journal of Esthetic and Restorative Dentistry 医学-牙科与口腔外科
CiteScore
6.30
自引率
6.20%
发文量
124
审稿时长
>12 weeks
期刊介绍: The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features. The range of topics covered in the journal includes: - Interdisciplinary esthetic concepts - Implants - Conservative adhesive restorations - Tooth Whitening - Prosthodontic materials and techniques - Dental materials - Orthodontic, periodontal and endodontic esthetics - Esthetics related research - Innovations in esthetics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信