{"title":"Comparing Methods to Mitigate the Effect of Grid Voltage Sag and Frequency Variation on the Operation of Variable Speed Drives","authors":"Mohamed Ibrahim, M. Nashed, M. Eskander","doi":"10.37394/232016.2024.19.2","DOIUrl":null,"url":null,"abstract":"In this paper, the effect of unsymmetrical grid voltage sag on the performance of a slip power recovery drive is studied, and two strategies to mitigate its effects are investigated. The first strategy consists of three phase parallel RL impedance connected to the rotor circuit. The second strategy consists of three phase LCL filter connected to the rotor circuit. A PI controller is tuned to test the drive at constant speed. Also, the effect of grid frequency drop on the drive performance is investigated with the same two protection strategies. The proposed systems are modeled with Matlab/Simulink and the simulation results are compared. The drive performance without any protection schemes are compared with its performance with the two proposed strategies. The compared results include the stator voltage and current, the rotor voltage and current, the DC link voltage and current, the electric torque, and the rotor speed.","PeriodicalId":38993,"journal":{"name":"WSEAS Transactions on Power Systems","volume":"107 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"WSEAS Transactions on Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37394/232016.2024.19.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
In this paper, the effect of unsymmetrical grid voltage sag on the performance of a slip power recovery drive is studied, and two strategies to mitigate its effects are investigated. The first strategy consists of three phase parallel RL impedance connected to the rotor circuit. The second strategy consists of three phase LCL filter connected to the rotor circuit. A PI controller is tuned to test the drive at constant speed. Also, the effect of grid frequency drop on the drive performance is investigated with the same two protection strategies. The proposed systems are modeled with Matlab/Simulink and the simulation results are compared. The drive performance without any protection schemes are compared with its performance with the two proposed strategies. The compared results include the stator voltage and current, the rotor voltage and current, the DC link voltage and current, the electric torque, and the rotor speed.
期刊介绍:
WSEAS Transactions on Power Systems publishes original research papers relating to electric power and energy. We aim to bring important work to a wide international audience and therefore only publish papers of exceptional scientific value that advance our understanding of these particular areas. The research presented must transcend the limits of case studies, while both experimental and theoretical studies are accepted. It is a multi-disciplinary journal and therefore its content mirrors the diverse interests and approaches of scholars involved with generation, transmission & distribution planning, alternative energy systems, power market, switching and related areas. We also welcome scholarly contributions from officials with government agencies, international agencies, and non-governmental organizations.