{"title":"Biometric description of 34 589 eyes undergoing cataract surgery: sex differences.","authors":"Marta Jiménez-García, Francisco J Segura-Calvo, Martín Puzo, Francisco J Castro-Alonso","doi":"10.1097/j.jcrs.0000000000001435","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To describe gender differences in the biometric parameters of a large sample of patients with cataract. Cataract surgery has evolved from a vision restoration to a refractive procedure, and population-based studies are vital to optimize normative databases and postsurgical outcomes.</p><p><strong>Setting: </strong>Miguel Servet University Hospital, Zaragoza, Spain.</p><p><strong>Design: </strong>Retrospective single-center observational study.</p><p><strong>Methods: </strong>The study included 34 589 eyes (20 004 patients with cataract). Biometric data were obtained from IOL Master 700 and Pentacam HR. Linear mixed models were used to account for intereye correlation. HofferQST formula was used to calculate the hypothetical distribution of intraocular lens (IOL) power (arbitrary lens; A = 119.2).</p><p><strong>Results: </strong>Most biometric variables showed significant differences between sexes ( P < .0001), such as 0.53 mm shorter eyes found in females, of which 0.16 mm are explained by shorter aqueous depth. Steeper anterior keratometries (∼0.75 diopter [D]) were found in women, to end up in no difference on anterior astigmatism magnitude, but different orientation ( P < .0001). The distribution of IOL power differed between sexes ( P < .001), with the interquartile range shifting 1 D toward more powerful lenses in women and odds ratio (power >26 D) = 2.26, P < .0001 (Fisher).</p><p><strong>Conclusions: </strong>Large sample size studies provide smaller margin of error, higher power, and controlled risk of reporting false (negative or positive) findings. Highly significant differences between sexes in ocular biometry were found; this supports the idea that including sex as a parameter in IOL calculation should be explored and may improve results. In addition, the distribution of IOL powers was provided, which may be useful for manufacturers and hospital stock planning.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"668-675"},"PeriodicalIF":2.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001435","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To describe gender differences in the biometric parameters of a large sample of patients with cataract. Cataract surgery has evolved from a vision restoration to a refractive procedure, and population-based studies are vital to optimize normative databases and postsurgical outcomes.
Setting: Miguel Servet University Hospital, Zaragoza, Spain.
Methods: The study included 34 589 eyes (20 004 patients with cataract). Biometric data were obtained from IOL Master 700 and Pentacam HR. Linear mixed models were used to account for intereye correlation. HofferQST formula was used to calculate the hypothetical distribution of intraocular lens (IOL) power (arbitrary lens; A = 119.2).
Results: Most biometric variables showed significant differences between sexes ( P < .0001), such as 0.53 mm shorter eyes found in females, of which 0.16 mm are explained by shorter aqueous depth. Steeper anterior keratometries (∼0.75 diopter [D]) were found in women, to end up in no difference on anterior astigmatism magnitude, but different orientation ( P < .0001). The distribution of IOL power differed between sexes ( P < .001), with the interquartile range shifting 1 D toward more powerful lenses in women and odds ratio (power >26 D) = 2.26, P < .0001 (Fisher).
Conclusions: Large sample size studies provide smaller margin of error, higher power, and controlled risk of reporting false (negative or positive) findings. Highly significant differences between sexes in ocular biometry were found; this supports the idea that including sex as a parameter in IOL calculation should be explored and may improve results. In addition, the distribution of IOL powers was provided, which may be useful for manufacturers and hospital stock planning.