{"title":"Evaluation of erythrocyte membrane oxidation due to their exposure to shear flow generated by extracorporeal blood pump.","authors":"Masataka Inoue, Yuki Udono, Yugo Kato, Koji Fukui, Nobuo Watanabe","doi":"10.1177/03913988241230942","DOIUrl":null,"url":null,"abstract":"<p><p>Several similarities have been found between shear stress-induced erythrocyte damage and physiological aging of erythrocytes in terms of elevated mechanical fragility, increased erythrocyte aggregation, and decreased membrane surface charge. Accordingly, we hypothesized that blood pump circulation, which generates shear stress, would accelerate erythrocyte aging, manifesting as oxidation. Therefore, the purpose of this study was to investigate the effect of blood pump circulation on erythrocyte oxidation. Fresh porcine blood was acquired from a slaughterhouse and anticoagulated with sodium citrate. About 500 mL of anticoagulated whole blood was circulated for 180 min in an in vitro test circuit comprising a BP-80 blood pump with a pump speed and a pump pressure head of 100-120 mmHg. A blood sample was taken at the start of the circulation and 180 min afterward. The hemolysis level and oxidation amount of the erythrocyte membrane were analyzed and compared between samples. Hemolysis increased with the prolongation of shear exposure inside the pump circuit. After 180 min of blood pumping in circuit, the oxidation level of the erythrocyte membrane showed an increase of 0.1 nmol/mg protein. Moreover, the membrane oxidation levels of sheared erythrocytes were greater than those of control erythrocytes. These results suggest that blood pump circulation accelerates erythrocyte aging and give us a greater understanding of the effects of blood pump perfusion.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10938486/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988241230942","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/29 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Several similarities have been found between shear stress-induced erythrocyte damage and physiological aging of erythrocytes in terms of elevated mechanical fragility, increased erythrocyte aggregation, and decreased membrane surface charge. Accordingly, we hypothesized that blood pump circulation, which generates shear stress, would accelerate erythrocyte aging, manifesting as oxidation. Therefore, the purpose of this study was to investigate the effect of blood pump circulation on erythrocyte oxidation. Fresh porcine blood was acquired from a slaughterhouse and anticoagulated with sodium citrate. About 500 mL of anticoagulated whole blood was circulated for 180 min in an in vitro test circuit comprising a BP-80 blood pump with a pump speed and a pump pressure head of 100-120 mmHg. A blood sample was taken at the start of the circulation and 180 min afterward. The hemolysis level and oxidation amount of the erythrocyte membrane were analyzed and compared between samples. Hemolysis increased with the prolongation of shear exposure inside the pump circuit. After 180 min of blood pumping in circuit, the oxidation level of the erythrocyte membrane showed an increase of 0.1 nmol/mg protein. Moreover, the membrane oxidation levels of sheared erythrocytes were greater than those of control erythrocytes. These results suggest that blood pump circulation accelerates erythrocyte aging and give us a greater understanding of the effects of blood pump perfusion.

评估红细胞膜因暴露于体外血液泵产生的剪切流而氧化的情况。
研究发现,剪切应力诱导的红细胞损伤与红细胞的生理性老化在机械脆性升高、红细胞聚集增加和膜表面电荷减少等方面有一些相似之处。因此,我们假设产生剪切应力的血泵循环会加速红细胞老化,表现为氧化。因此,本研究旨在探讨血泵循环对红细胞氧化的影响。从屠宰场采集新鲜猪血并用柠檬酸钠抗凝。约 500 毫升抗凝全血在由 BP-80 血泵组成的体外测试回路中循环 180 分钟,血泵速度和泵压头为 100-120 毫米汞柱。在循环开始时和循环结束后 180 分钟内采集血液样本。分析溶血水平和红细胞膜的氧化量,并对不同样本进行比较。随着泵回路内剪切暴露时间的延长,溶血量也在增加。在回路中抽血 180 分钟后,红细胞膜的氧化水平增加了 0.1 nmol/mg 蛋白。此外,剪切红细胞膜氧化水平高于对照红细胞膜氧化水平。这些结果表明,血泵循环加速了红细胞的衰老,使我们对血泵灌注的影响有了更深入的了解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Artificial Organs
International Journal of Artificial Organs 医学-工程:生物医学
CiteScore
3.40
自引率
5.90%
发文量
92
审稿时长
3 months
期刊介绍: The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信