An optimized 3T MRI scan protocol to assess iris melanoma with subsequent histopathological verification – A prospective study

IF 3.7 3区 医学 Q1 OPHTHALMOLOGY
Joevy Z. Lim , Akilesh Gokul , Stuti L. Misra , Xingzheng Pan , Amanda Charlton , Charles N.J. McGhee
{"title":"An optimized 3T MRI scan protocol to assess iris melanoma with subsequent histopathological verification – A prospective study","authors":"Joevy Z. Lim ,&nbsp;Akilesh Gokul ,&nbsp;Stuti L. Misra ,&nbsp;Xingzheng Pan ,&nbsp;Amanda Charlton ,&nbsp;Charles N.J. McGhee","doi":"10.1016/j.apjo.2024.100047","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Magnetic resonance imaging (MRI) has demonstrated high levels of tissue contrast, accuracy and reproducibility in evaluating posterior uveal melanoma. Owing to smaller size, the role of MRI in detecting and characterising iris melanoma has not yet been explored. Aims: To develop a protocol to image iris melanoma and describe the MRI characteristics of histopathological-confirmed iris melanoma.</p></div><div><h3>Materials and methods</h3><p>An optimised MRI protocol, using a 3T MRI scanner and a 32-channel head coil, was developed to image iris tumours. A prospective, single-centre, 12-month study was conducted on all patients with lesions suspicious for iris melanoma. All patients were offered an MRI scan in addition to the standardised clinical procedures. Image quality comparison was made with existing clinical investigations. Iris melanoma characteristics on MRI are described.</p></div><div><h3>Results</h3><p>A successful optimised MRI scan protocol was developed that was able to detect and characterise iris melanoma. One normal participant and five patients with subsequent histopathological-confirmed iris melanoma (n = 6) were recruited. Four patients completed the full MRI sequence. All iris melanoma were detected on at least one T1- or T2-weighted images. When compared to the vitreous, all iris melanomas demonstrated hyper-intensity on T1-weighted images and hypo-intensity on T2-weighted images. On T1-mapping, T1-values of iris melanoma demonstrated an inverse relationship with the degree of tumour pigmentation.</p></div><div><h3>Conclusions</h3><p>This study highlights an optimised, easily reproducible MRI scan protocol to image iris melanoma. Numerous MR imaging characteristics of iris melanoma are reported for the first time and a potential non-invasive tumour biomarker is described.</p></div>","PeriodicalId":8594,"journal":{"name":"Asia-Pacific Journal of Ophthalmology","volume":"13 2","pages":"Article 100047"},"PeriodicalIF":3.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2162098924000422/pdfft?md5=83747ae401ee0d43d720708a9f770ffe&pid=1-s2.0-S2162098924000422-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2162098924000422","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Magnetic resonance imaging (MRI) has demonstrated high levels of tissue contrast, accuracy and reproducibility in evaluating posterior uveal melanoma. Owing to smaller size, the role of MRI in detecting and characterising iris melanoma has not yet been explored. Aims: To develop a protocol to image iris melanoma and describe the MRI characteristics of histopathological-confirmed iris melanoma.

Materials and methods

An optimised MRI protocol, using a 3T MRI scanner and a 32-channel head coil, was developed to image iris tumours. A prospective, single-centre, 12-month study was conducted on all patients with lesions suspicious for iris melanoma. All patients were offered an MRI scan in addition to the standardised clinical procedures. Image quality comparison was made with existing clinical investigations. Iris melanoma characteristics on MRI are described.

Results

A successful optimised MRI scan protocol was developed that was able to detect and characterise iris melanoma. One normal participant and five patients with subsequent histopathological-confirmed iris melanoma (n = 6) were recruited. Four patients completed the full MRI sequence. All iris melanoma were detected on at least one T1- or T2-weighted images. When compared to the vitreous, all iris melanomas demonstrated hyper-intensity on T1-weighted images and hypo-intensity on T2-weighted images. On T1-mapping, T1-values of iris melanoma demonstrated an inverse relationship with the degree of tumour pigmentation.

Conclusions

This study highlights an optimised, easily reproducible MRI scan protocol to image iris melanoma. Numerous MR imaging characteristics of iris melanoma are reported for the first time and a potential non-invasive tumour biomarker is described.

评估虹膜黑色素瘤并随后进行组织病理学验证的优化 3T 磁共振成像扫描方案--一项前瞻性研究。
介绍:磁共振成像(MRI)在评估后葡萄膜黑色素瘤时已显示出较高的组织对比度、准确性和可重复性。目的:制定虹膜黑色素瘤成像方案,并描述组织病理学证实的虹膜黑色素瘤的磁共振成像特征:使用 3T 磁共振成像扫描仪和 32 通道头部线圈,制定了一套优化的磁共振成像方案,用于对虹膜肿瘤进行成像。对所有疑似虹膜黑色素瘤的患者进行了为期 12 个月的前瞻性单中心研究。除标准化临床程序外,所有患者都接受了磁共振成像扫描。图像质量与现有的临床检查结果进行了比较。结果:结果:成功制定了优化的核磁共振成像扫描方案,能够检测出虹膜黑色素瘤并确定其特征。研究人员招募了一名正常参与者和五名组织病理学确诊的虹膜黑色素瘤患者(n = 6)。四名患者完成了整个核磁共振成像序列。所有虹膜黑色素瘤都至少在一张T1或T2加权图像上被检测到。与玻璃体相比,所有虹膜黑色素瘤在T1加权图像上都表现为高强度,而在T2加权图像上则表现为低强度。在 T1 映射中,虹膜黑色素瘤的 T1 值与肿瘤色素沉着程度呈反比关系:本研究强调了一种优化的、易于重复的磁共振成像扫描方案,用于对虹膜黑色素瘤进行成像。该研究首次报道了虹膜黑色素瘤的许多磁共振成像特征,并描述了一种潜在的非侵入性肿瘤生物标记物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.10
自引率
18.20%
发文量
197
审稿时长
6 weeks
期刊介绍: The Asia-Pacific Journal of Ophthalmology, a bimonthly, peer-reviewed online scientific publication, is an official publication of the Asia-Pacific Academy of Ophthalmology (APAO), a supranational organization which is committed to research, training, learning, publication and knowledge and skill transfers in ophthalmology and visual sciences. The Asia-Pacific Journal of Ophthalmology welcomes review articles on currently hot topics, original, previously unpublished manuscripts describing clinical investigations, clinical observations and clinically relevant laboratory investigations, as well as .perspectives containing personal viewpoints on topics with broad interests. Editorials are published by invitation only. Case reports are generally not considered. The Asia-Pacific Journal of Ophthalmology covers 16 subspecialties and is freely circulated among individual members of the APAO’s member societies, which amounts to a potential readership of over 50,000.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信