{"title":"Pure endoscopic transcanal revision cochlear implantation for a misplaced electrode array: A novel and minimally invasive approach.","authors":"Secaattin Gülşen, Sercan Çıkrıkcı","doi":"10.1080/14670100.2024.2318082","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Misplacement of the CI electrode array is one of the rarest complications of cochlear implant surgery. This condition can be noticed intraoperatively and diagnosed radiologically in the early postoperative period. To present a novel and minimally invasive revision approach for a misplaced cochlear implant (CI) electrode array.</p><p><strong>Case: </strong>In this case report, the authors present a previously undescribed alternative minimally invasive revision cochlear implantation approach for a patient with a misplaced CI electrode array in the right ear who underwent bilateral simultaneous cochlear implantation one and a half years ago at another center.</p><p><strong>Conclusion: </strong>To correct CI electrode array misplacement, the endoscopic transcanal approach is a safe and effective alternative to the conventional approach.</p>","PeriodicalId":53553,"journal":{"name":"COCHLEAR IMPLANTS INTERNATIONAL","volume":" ","pages":"248-253"},"PeriodicalIF":1.4000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"COCHLEAR IMPLANTS INTERNATIONAL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14670100.2024.2318082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Misplacement of the CI electrode array is one of the rarest complications of cochlear implant surgery. This condition can be noticed intraoperatively and diagnosed radiologically in the early postoperative period. To present a novel and minimally invasive revision approach for a misplaced cochlear implant (CI) electrode array.
Case: In this case report, the authors present a previously undescribed alternative minimally invasive revision cochlear implantation approach for a patient with a misplaced CI electrode array in the right ear who underwent bilateral simultaneous cochlear implantation one and a half years ago at another center.
Conclusion: To correct CI electrode array misplacement, the endoscopic transcanal approach is a safe and effective alternative to the conventional approach.
目的:人工耳蜗电极阵列错位是人工耳蜗植入手术中最罕见的并发症之一。这种情况可在术中发现,并在术后早期通过放射学诊断出来。病例:在本病例报告中,作者介绍了一种之前未曾描述过的微创人工耳蜗植入翻修方法,该方法适用于一名右耳人工耳蜗电极阵列错位的患者,该患者一年半前在另一家中心接受了双侧同时人工耳蜗植入手术:结论:对于纠正 CI 电极阵列错位,内窥镜经耳道方法是传统方法的一种安全有效的替代方法。
期刊介绍:
Cochlear Implants International was founded as an interdisciplinary, peer-reviewed journal in response to the growing number of publications in the field of cochlear implants. It was designed to meet a need to include scientific contributions from all the disciplines that are represented in cochlear implant teams: audiology, medicine and surgery, speech therapy and speech pathology, psychology, hearing therapy, radiology, pathology, engineering and acoustics, teaching, and communication. The aim was to found a truly interdisciplinary journal, representing the full breadth of the field of cochlear implantation.