Noninvasive pediatric blood pressure assessment: exploring the clinicians' perspective.

IF 1.2 4区 医学 Q4 PERIPHERAL VASCULAR DISEASE
Blood Pressure Monitoring Pub Date : 2024-06-01 Epub Date: 2024-02-19 DOI:10.1097/MBP.0000000000000693
Natalie P Stewart, Catherine Quinlan, Stephanie Best, Jonathan P Mynard
{"title":"Noninvasive pediatric blood pressure assessment: exploring the clinicians' perspective.","authors":"Natalie P Stewart, Catherine Quinlan, Stephanie Best, Jonathan P Mynard","doi":"10.1097/MBP.0000000000000693","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Obtaining accurate and reliable blood pressure (BP) readings in pediatric patients is challenging, given difficulties in adhering to measurement guidelines, limited device validation and variable patient cooperation. This study aimed to investigate clinicians' perspectives surrounding noninvasive pediatric BP assessment to identify opportunities for improvement in BP technology and clinical practice.</p><p><strong>Method: </strong>Based on an adapted version of the extended Technology Acceptance Model 2, semi-structured interviews were conducted with clinicians involved in noninvasive pediatric BP assessment in a major Australian children's hospital. Transcripts were analyzed thematically and guided by Technology Acceptance Model 2.</p><p><strong>Results: </strong>Clinician responses ( n  = 20) revealed that poor patient tolerance of BP measurement resulting from excessive cuff inflation is a major hindrance to reliable pediatric BP assessment. Clinicians described low trust in BP readings from automated devices, often relating to poor patient tolerance to cuff inflation, thereby diminishing the clinical utility of these readings in informing treatment decisions. Auscultatory measurement was regarded as more trustworthy and better tolerated, but less convenient to perform as compared with oscillometric measurement.</p><p><strong>Conclusion: </strong>A dissonance exists between (1) low trust and clinical utility of the most common and easy-to-use BP measurement approach (automated devices), versus (2) higher trust and clinical utility, but efficiency and user-related impediments, for the auscultatory method. Based on our results, we have developed the Blood Pressure Acceptance Model, which can be used to explain and predict clinicians' acceptance of BP technology. Further work is needed to improve the tolerability and accuracy of automated BP devices in real-world pediatric settings.</p>","PeriodicalId":8950,"journal":{"name":"Blood Pressure Monitoring","volume":" ","pages":"127-135"},"PeriodicalIF":1.2000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000693","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/19 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Obtaining accurate and reliable blood pressure (BP) readings in pediatric patients is challenging, given difficulties in adhering to measurement guidelines, limited device validation and variable patient cooperation. This study aimed to investigate clinicians' perspectives surrounding noninvasive pediatric BP assessment to identify opportunities for improvement in BP technology and clinical practice.

Method: Based on an adapted version of the extended Technology Acceptance Model 2, semi-structured interviews were conducted with clinicians involved in noninvasive pediatric BP assessment in a major Australian children's hospital. Transcripts were analyzed thematically and guided by Technology Acceptance Model 2.

Results: Clinician responses ( n  = 20) revealed that poor patient tolerance of BP measurement resulting from excessive cuff inflation is a major hindrance to reliable pediatric BP assessment. Clinicians described low trust in BP readings from automated devices, often relating to poor patient tolerance to cuff inflation, thereby diminishing the clinical utility of these readings in informing treatment decisions. Auscultatory measurement was regarded as more trustworthy and better tolerated, but less convenient to perform as compared with oscillometric measurement.

Conclusion: A dissonance exists between (1) low trust and clinical utility of the most common and easy-to-use BP measurement approach (automated devices), versus (2) higher trust and clinical utility, but efficiency and user-related impediments, for the auscultatory method. Based on our results, we have developed the Blood Pressure Acceptance Model, which can be used to explain and predict clinicians' acceptance of BP technology. Further work is needed to improve the tolerability and accuracy of automated BP devices in real-world pediatric settings.

无创儿科血压评估:探索临床医生的视角。
背景:在儿科患者中获取准确可靠的血压(BP)读数具有挑战性,因为很难遵守测量指南、设备验证有限以及患者合作程度不一。本研究旨在调查临床医生对无创儿科血压评估的看法,以确定改进血压技术和临床实践的机会:方法:根据经过改编的扩展技术接受模型 2,对澳大利亚一家大型儿童医院参与无创儿科血压评估的临床医生进行了半结构式访谈。在技术接受模式 2 的指导下,对访谈记录进行了专题分析:临床医生的回答(n = 20)显示,袖带过度充气导致患者对血压测量的耐受性差是阻碍可靠的儿科血压评估的主要原因。临床医生对自动设备的血压读数信任度较低,这往往与患者对袖带充气的耐受性差有关,从而降低了这些读数在为治疗决策提供信息方面的临床实用性。听诊法测量被认为更值得信赖,患者的耐受性更好,但与示波法测量相比,听诊法测量不太方便:结论:(1) 最常见、最易用的血压测量方法(自动设备)的信任度和临床实用性较低,而(2) 听诊法的信任度和临床实用性较高,但效率和用户相关障碍较高,这两者之间存在不一致。根据我们的研究结果,我们建立了血压接受度模型,该模型可用于解释和预测临床医生对血压技术的接受度。要提高自动血压设备在实际儿科环境中的耐受性和准确性,还需要进一步的工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Blood Pressure Monitoring
Blood Pressure Monitoring 医学-外周血管病
CiteScore
2.00
自引率
7.70%
发文量
110
审稿时长
>12 weeks
期刊介绍: Blood Pressure Monitoring is devoted to original research in blood pressure measurement and blood pressure variability. It includes device technology, analytical methodology of blood pressure over time and its variability, clinical trials - including, but not limited to, pharmacology - involving blood pressure monitoring, blood pressure reactivity, patient evaluation, and outcomes and effectiveness research. This innovative journal contains papers dealing with all aspects of manual, automated, and ambulatory monitoring. Basic and clinical science papers are considered although the emphasis is on clinical medicine. Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信