Non-enzymatic electrochemical sensing platform based on metal oxide-loaded biopolymer for voltammetric measurement of hepatoprotective metadoxine drug in pharmaceutical formulation and human blood serum

IF 10.61 Q3 Biochemistry, Genetics and Molecular Biology
Manish S. Sengar , Priya Kumari , Neha Sengar , Soami P. Satsangee , Rajeev Jain
{"title":"Non-enzymatic electrochemical sensing platform based on metal oxide-loaded biopolymer for voltammetric measurement of hepatoprotective metadoxine drug in pharmaceutical formulation and human blood serum","authors":"Manish S. Sengar ,&nbsp;Priya Kumari ,&nbsp;Neha Sengar ,&nbsp;Soami P. Satsangee ,&nbsp;Rajeev Jain","doi":"10.1016/j.biosx.2024.100453","DOIUrl":null,"url":null,"abstract":"<div><p>This study focuses on the first-ever high-sensitivity, low-cost, and quick response electrochemical estimation of metadoxine (MTD) in pharmaceuticals and human blood serum using a non-enzymatic nanocomposite modified glassy carbon electrode (CuO/CH/GCE) loaded with chitosan. The electroactive surface of GCE was produced by drop-casting a suspension of CuO/CH nanocomposite in N,N-dimethylformamide (DMF) onto the non-enzymatic electrode surface. Synthesized nanocomposite was characterised by using XRD, XPS, EDX, TEM, Raman and FESEM techniques. EIS technique was utilized to study the enhanced charge-transfer phenomenon occurring at the surface of modified sensor. The electrooxidation of MTD at CuO/CH/GCE surface is depending at pH of supporting electrolyte, scan rate and concentration of analyte. CV and SWV technique were used to carry out electrochemical study, optimised voltammetric response is observed in the BR buffer at pH 2.5, with irreversible diffusion-controlled process. Within the linear concentration range of MTD from 1.99 μg/L to 29.56 μg/L, this sensor exhibited lowest LOD (0.64 μg/L) and LOQ (2.14 μg/L). The MTD in pharmaceutical formulation and human blood serum can be determined with this highly selective peak potential (Ep ∼ 1.2 V), repeatable (%RSD 0.91), and reproducible (%RSD 2.31) method. The average percentage recovery in human blood serum and pharmaceutical formulation is 99.89% and 99.90%. This paper reports a lowest LOD value for MTD detection in the comparison with other reported methods (Table S1). None of the selected excipients were found to interfere more than 5% with redox potential of MTD without affecting the performance of sensor.</p></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"17 ","pages":"Article 100453"},"PeriodicalIF":10.6100,"publicationDate":"2024-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2590137024000177/pdfft?md5=109df676fa512a6da046be990582ac28&pid=1-s2.0-S2590137024000177-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137024000177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

This study focuses on the first-ever high-sensitivity, low-cost, and quick response electrochemical estimation of metadoxine (MTD) in pharmaceuticals and human blood serum using a non-enzymatic nanocomposite modified glassy carbon electrode (CuO/CH/GCE) loaded with chitosan. The electroactive surface of GCE was produced by drop-casting a suspension of CuO/CH nanocomposite in N,N-dimethylformamide (DMF) onto the non-enzymatic electrode surface. Synthesized nanocomposite was characterised by using XRD, XPS, EDX, TEM, Raman and FESEM techniques. EIS technique was utilized to study the enhanced charge-transfer phenomenon occurring at the surface of modified sensor. The electrooxidation of MTD at CuO/CH/GCE surface is depending at pH of supporting electrolyte, scan rate and concentration of analyte. CV and SWV technique were used to carry out electrochemical study, optimised voltammetric response is observed in the BR buffer at pH 2.5, with irreversible diffusion-controlled process. Within the linear concentration range of MTD from 1.99 μg/L to 29.56 μg/L, this sensor exhibited lowest LOD (0.64 μg/L) and LOQ (2.14 μg/L). The MTD in pharmaceutical formulation and human blood serum can be determined with this highly selective peak potential (Ep ∼ 1.2 V), repeatable (%RSD 0.91), and reproducible (%RSD 2.31) method. The average percentage recovery in human blood serum and pharmaceutical formulation is 99.89% and 99.90%. This paper reports a lowest LOD value for MTD detection in the comparison with other reported methods (Table S1). None of the selected excipients were found to interfere more than 5% with redox potential of MTD without affecting the performance of sensor.

基于金属氧化物负载生物聚合物的非酶电化学传感平台,用于伏安法测量药物制剂和人体血清中的保肝药物美他多辛
本研究的重点是首次使用负载壳聚糖的非酶纳米复合修饰玻璃碳电极(CuO/CH/GCE),对药物和人体血清中的甲胺多辛(MTD)进行高灵敏度、低成本和快速响应的电化学估测。通过将 CuO/CH 纳米复合材料在 N,N-二甲基甲酰胺(DMF)中的悬浮液滴铸到非酶电极表面,制得了 GCE 的电活性表面。利用 XRD、XPS、EDX、TEM、拉曼和 FESEM 技术对合成的纳米复合材料进行了表征。利用 EIS 技术研究了改性传感器表面发生的电荷转移增强现象。MTD 在 CuO/CH/GCE 表面的电氧化作用取决于支持电解质的 pH 值、扫描速率和分析物浓度。利用 CV 和 SWV 技术进行了电化学研究,在 pH 值为 2.5 的 BR 缓冲液中观察到了最佳伏安反应,该反应具有不可逆的扩散控制过程。在 MTD 1.99 μg/L 至 29.56 μg/L 的线性浓度范围内,该传感器表现出最低的 LOD(0.64 μg/L)和 LOQ(2.14 μg/L)。该方法具有峰电位选择性高(Ep ∼ 1.2 V)、重复性好(%RSD 0.91)、再现性好(%RSD 2.31)等特点,可用于测定药物制剂和人体血清中的 MTD。在人血清和药物制剂中的平均回收率分别为 99.89% 和 99.90%。与其他已报道的方法相比,本文报告的 MTD 检测 LOD 值最低(表 S1)。所选辅料对 MTD 氧化还原电位的干扰均不超过 5%,不会影响传感器的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors and Bioelectronics: X
Biosensors and Bioelectronics: X Biochemistry, Genetics and Molecular Biology-Biophysics
CiteScore
4.60
自引率
0.00%
发文量
166
审稿时长
54 days
期刊介绍: Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信