Comparison of craniometric measurements of New Zealand rabbit (Oryctolagus cuniculus L.) using three-dimensional scanner with digital calliper measurements: A methodological study
{"title":"Comparison of craniometric measurements of New Zealand rabbit (Oryctolagus cuniculus L.) using three-dimensional scanner with digital calliper measurements: A methodological study","authors":"Ali Koçyiğit, İsmail Demircioğlu","doi":"10.1111/ahe.13023","DOIUrl":null,"url":null,"abstract":"<p>As technology has developed in recent years, the use of three-dimensional (3D) scanners and printers has become widespread in the medical field. However, since this field is new, all kinds of methodological and experimental related studies gain importance. This study aimed to identify the differences between the calliper measurements by determining the craniometric data on the models constructed by scanning the crania of New Zealand Rabbits (<i>Oryctolagus cuniculus</i> L.), preferred as experimental animals, with a three-dimensional scanner. Therefore, a total of 12 New Zealand rabbits including 6 females and 6 males were used. After the crania that comprised the study material were macerated, they were subjected to 3D scanning. After the scanning process was completed, they were craniometrically measured both on the scanned models and by using a digital calliper. Analysis of the craniometric data of the 3D scanner showed that there was a difference between sexes at the level of <i>p</i> < 0.05 in widest length between the external acoustic meatus (WLBEAM), skull width and Foramen magnum height (FMH) parameters and cranial index data, and at the level of <i>p</i> < 0.001 in the largest nasal width (LNW) parameter. A statistical difference was found between sexes in frontal length, WLBEAM, LNW and FMH parameters and cranial index values in craniometric data collected with the digital calliper (<i>p</i> < 0.05). Consequently, the data collected in this study were found to be close to each other in both methods, suggesting that the 3D scanner may be used in morphometric studies.</p>","PeriodicalId":49290,"journal":{"name":"Anatomia Histologia Embryologia","volume":"53 2","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anatomia Histologia Embryologia","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ahe.13023","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
As technology has developed in recent years, the use of three-dimensional (3D) scanners and printers has become widespread in the medical field. However, since this field is new, all kinds of methodological and experimental related studies gain importance. This study aimed to identify the differences between the calliper measurements by determining the craniometric data on the models constructed by scanning the crania of New Zealand Rabbits (Oryctolagus cuniculus L.), preferred as experimental animals, with a three-dimensional scanner. Therefore, a total of 12 New Zealand rabbits including 6 females and 6 males were used. After the crania that comprised the study material were macerated, they were subjected to 3D scanning. After the scanning process was completed, they were craniometrically measured both on the scanned models and by using a digital calliper. Analysis of the craniometric data of the 3D scanner showed that there was a difference between sexes at the level of p < 0.05 in widest length between the external acoustic meatus (WLBEAM), skull width and Foramen magnum height (FMH) parameters and cranial index data, and at the level of p < 0.001 in the largest nasal width (LNW) parameter. A statistical difference was found between sexes in frontal length, WLBEAM, LNW and FMH parameters and cranial index values in craniometric data collected with the digital calliper (p < 0.05). Consequently, the data collected in this study were found to be close to each other in both methods, suggesting that the 3D scanner may be used in morphometric studies.
期刊介绍:
Anatomia, Histologia, Embryologia is a premier international forum for the latest research on descriptive, applied and clinical anatomy, histology, embryology, and related fields. Special emphasis is placed on the links between animal morphology and veterinary and experimental medicine, consequently studies on clinically relevant species will be given priority. The editors welcome papers on medical imaging and anatomical techniques. The journal is of vital interest to clinicians, zoologists, obstetricians, and researchers working in biotechnology. Contributions include reviews, original research articles, short communications and book reviews.