M Dawson, C M McGee, P M Brooks, J H Vine, T R Watson
{"title":"Quantification of leukotriene B4 in synovial fluid by gas chromatography/tandem mass spectrometry.","authors":"M Dawson, C M McGee, P M Brooks, J H Vine, T R Watson","doi":"10.1002/bms.1200170309","DOIUrl":null,"url":null,"abstract":"<p><p>A procedure for the quantification of leukotriene B4 (LTB4) in synovial fluid has been developed using gas chromatography/tandem mass spectrometry based on selected reaction monitoring of the elimination of t-butyldimethylsilanol from the ions of m/z 431 and 438 in the negative ion chemical ionization mass spectra of the di-t-butyldimethylsilyl/pentafluorobenzyl derivatives of leukotriene B4 and the internal standard (2H8)leukotriene B4. The detection limit (approximately 10 pg ml-1) is sufficiently low to permit determination of LTB4 concentration in the synovial fluid of patients with various arthropathies. Single-stage mass spectrometry was found not to be selective enough to permit quantification of LTB4 in synovial fluid.</p>","PeriodicalId":8924,"journal":{"name":"Biomedical & environmental mass spectrometry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1988-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/bms.1200170309","citationCount":"88","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical & environmental mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/bms.1200170309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 88
Abstract
A procedure for the quantification of leukotriene B4 (LTB4) in synovial fluid has been developed using gas chromatography/tandem mass spectrometry based on selected reaction monitoring of the elimination of t-butyldimethylsilanol from the ions of m/z 431 and 438 in the negative ion chemical ionization mass spectra of the di-t-butyldimethylsilyl/pentafluorobenzyl derivatives of leukotriene B4 and the internal standard (2H8)leukotriene B4. The detection limit (approximately 10 pg ml-1) is sufficiently low to permit determination of LTB4 concentration in the synovial fluid of patients with various arthropathies. Single-stage mass spectrometry was found not to be selective enough to permit quantification of LTB4 in synovial fluid.