Design and simulation of a nano biosensor based on amorphous indium gallium zinc oxide (a-IGZO) thin film transistor

Z. Ahangari
{"title":"Design and simulation of a nano biosensor based on amorphous indium gallium zinc oxide (a-IGZO) thin film transistor","authors":"Z. Ahangari","doi":"10.1088/1361-6641/ad28f4","DOIUrl":null,"url":null,"abstract":"\n In this study, a biosensor utilizing a dielectric-modulated Amorphous Indium Gallium Zinc Oxide (a-IGZO) thin film transistor (TFT) is introduced. Thin film transistor biosensors have garnered significant attention due to their heightened sensitivity, scalable nature, low power consumption, rapid electrical detection capabilities, and cost-effective means of mass production. By embedding a nano-cavity within the gate insulator of the TFT, biomolecules can accumulate within. As each biomolecule possesses its own dielectric constant, it modulates the effective gate capacitance and, subsequently, changes the channel conductance. To assess the sensitivity of the biosensor, variation in saturation current after the absorption of biomolecules with respect to the drain current in the case of an air-filled cavity has been considered as a precise measure. The efficient operation of a biosensor is contingent upon the sensitivity being highly dependent on the dielectric constant of the biomolecules that are accumulated within the nano-cavity. Consequently, a comprehensive evaluation has been conducted to ascertain the impact of critical design parameters which have the potential to affect the sensitivity of the biosensor. Additionally, a statistical analysis based on coefficient of variation measure has been performed to evaluate the susceptibility of the biosensor's sensitivity to variations in geometrical and physical design parameters. The utilization of label-free detection methodology in this device presents a notable advantage due to its compatibility with the fundamental CMOS processing technology and its cost-effective potential for macro production.","PeriodicalId":507064,"journal":{"name":"Semiconductor Science and Technology","volume":"133 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Semiconductor Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1361-6641/ad28f4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a biosensor utilizing a dielectric-modulated Amorphous Indium Gallium Zinc Oxide (a-IGZO) thin film transistor (TFT) is introduced. Thin film transistor biosensors have garnered significant attention due to their heightened sensitivity, scalable nature, low power consumption, rapid electrical detection capabilities, and cost-effective means of mass production. By embedding a nano-cavity within the gate insulator of the TFT, biomolecules can accumulate within. As each biomolecule possesses its own dielectric constant, it modulates the effective gate capacitance and, subsequently, changes the channel conductance. To assess the sensitivity of the biosensor, variation in saturation current after the absorption of biomolecules with respect to the drain current in the case of an air-filled cavity has been considered as a precise measure. The efficient operation of a biosensor is contingent upon the sensitivity being highly dependent on the dielectric constant of the biomolecules that are accumulated within the nano-cavity. Consequently, a comprehensive evaluation has been conducted to ascertain the impact of critical design parameters which have the potential to affect the sensitivity of the biosensor. Additionally, a statistical analysis based on coefficient of variation measure has been performed to evaluate the susceptibility of the biosensor's sensitivity to variations in geometrical and physical design parameters. The utilization of label-free detection methodology in this device presents a notable advantage due to its compatibility with the fundamental CMOS processing technology and its cost-effective potential for macro production.
基于非晶铟镓锌氧化物(a-IGZO)薄膜晶体管的纳米生物传感器的设计与仿真
本研究介绍了一种利用介电调制非晶氧化铟镓锌薄膜晶体管(TFT)的生物传感器。薄膜晶体管生物传感器因其灵敏度高、可扩展、功耗低、快速电检测能力以及大规模生产的成本效益高而备受关注。通过在 TFT 的栅极绝缘体中嵌入一个纳米空腔,生物分子就可以积聚在其中。由于每种生物分子都有自己的介电常数,因此会调节有效栅极电容,进而改变通道电导。为了评估生物传感器的灵敏度,在充满空气的空腔中,吸收生物分子后的饱和电流相对于漏极电流的变化被认为是一种精确的测量方法。生物传感器的有效运行取决于灵敏度是否高度依赖于纳米腔内积聚的生物分子的介电常数。因此,我们进行了一项综合评估,以确定有可能影响生物传感器灵敏度的关键设计参数的影响。此外,还进行了基于变异系数测量的统计分析,以评估生物传感器的灵敏度对几何和物理设计参数变化的敏感性。在该装置中使用无标记检测方法具有显著的优势,因为它与基本的 CMOS 处理技术兼容,而且在大规模生产中具有成本效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书