Effect of the cathode surface temperature on the cathode fall layer parameters: experiment and simulation

Leanid Simonchik, Mikalai Tomkavich, Gubad Islamov, E. Eylenceoglu, Ismail Rafatov
{"title":"Effect of the cathode surface temperature on the cathode fall layer parameters: experiment and simulation","authors":"Leanid Simonchik, Mikalai Tomkavich, Gubad Islamov, E. Eylenceoglu, Ismail Rafatov","doi":"10.1088/1361-6595/ad2580","DOIUrl":null,"url":null,"abstract":"\n Combined experimental and numerical studies reveal a significant effect of the cathode temperature on the basic parameters (such as the electric field profile, thickness of the cathode fall layer, current density, and gas temperature) of the cathode fall of the self-sustained normal DC atmospheric pressure glow discharge (APGD) in helium. Numerical models are spatially one- and two-dimensional and based on drift-diffusion theory of gas discharges. It was observed that heating of the cathode, resulting from a flow of the discharge current in APGD with a constricted positive column, leads to an increase of the interelectrode voltage if the cathode is not cooled and its temperature increases. With additional heating of the cathode by an external heat source, the interelectrode voltage tends to decrease. Radially inhomogeneous profiles of the reduced electric field on the uncooled cathode surface were measured. Simulation results exhibit reasonably good agreement with experiment for APGDs with cooled and uncooled cathodes.","PeriodicalId":508056,"journal":{"name":"Plasma Sources Science and Technology","volume":"9 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Sources Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1361-6595/ad2580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Combined experimental and numerical studies reveal a significant effect of the cathode temperature on the basic parameters (such as the electric field profile, thickness of the cathode fall layer, current density, and gas temperature) of the cathode fall of the self-sustained normal DC atmospheric pressure glow discharge (APGD) in helium. Numerical models are spatially one- and two-dimensional and based on drift-diffusion theory of gas discharges. It was observed that heating of the cathode, resulting from a flow of the discharge current in APGD with a constricted positive column, leads to an increase of the interelectrode voltage if the cathode is not cooled and its temperature increases. With additional heating of the cathode by an external heat source, the interelectrode voltage tends to decrease. Radially inhomogeneous profiles of the reduced electric field on the uncooled cathode surface were measured. Simulation results exhibit reasonably good agreement with experiment for APGDs with cooled and uncooled cathodes.
阴极表面温度对阴极下落层参数的影响:实验与模拟
结合实验和数值研究发现,阴极温度对氦气中自持续正常直流大气压辉光放电(APGD)阴极落差的基本参数(如电场剖面、阴极落差层厚度、电流密度和气体温度)有显著影响。数值模型为空间一维和二维模型,基于气体放电的漂移扩散理论。研究发现,如果阴极未被冷却且温度升高,在正极柱收缩的 APGD 中,放电电流的流动会导致阴极加热,从而导致电极间电压升高。通过外部热源对阴极进行额外加热后,电极间电压趋于降低。测量了未冷却阴极表面上的还原电场的径向不均匀剖面。对于具有冷却和非冷却阴极的 APGD,模拟结果与实验结果具有相当好的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信