Whole Blood Cardiac Troponin "Triaging" to Improve Early Detection of Myocardial Injury at a Pediatric Hospital.

IF 1.8 Q3 MEDICAL LABORATORY TECHNOLOGY
Lawrence de Koning, Isolde Seiden-Long, Katherine Anker, Kimberley Myers, Antonia Stang
{"title":"Whole Blood Cardiac Troponin \"Triaging\" to Improve Early Detection of Myocardial Injury at a Pediatric Hospital.","authors":"Lawrence de Koning, Isolde Seiden-Long, Katherine Anker, Kimberley Myers, Antonia Stang","doi":"10.1093/jalm/jfad133","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The importance of offering on-site cardiac troponin (cTn) testing at pediatric hospitals may be underappreciated. We developed a rapid rule-in process for myocardial injury at a pediatric hospital experiencing delays in off-site high-sensitivity cardiac troponin T (hs-cTnT) testing.</p><p><strong>Methods: </strong>Collect-to-verify turnaround times (TATs) for off-site testing were reviewed. Pre-analytic changes to improve TATs were devised, implemented and evaluated, after which a new analyzer was selected and evaluated for on-site cTn testing. Performance of the new analyzer's assay was compared to the off-site hs-cTnT assay, and post go-live TATs for on-site testing were assessed.</p><p><strong>Results: </strong>Median collect-to-verify TAT for short turnaround-time (STAT) priority off-site plasma hs-cTnT testing was 104 min, with 35% of orders having a TAT >120 min. Eliminating serum separator tubes and requiring a separate plasma separator tube did not significantly reduce TATs. A QuidelOrtho Triage® MeterPro whole blood cardiac troponin I (cTnI) assay was implemented to \"triage\" time-critical and STAT priority specimens collected for off-site hs-cTnT testing. Elevated cTnI (≥0.02 µg/L) had a sensitivity of 91% for clear elevations in hs-cTnT (≥53 ng/L) but a 0% sensitivity for modest elevations (5 to 13 ng/L, 14 to 52 ng/L). An interpretive comment was auto-appended to cTnI results indicating that clinicians should wait for the hs-cTnT result if cTnI was normal. Median collect-to-verify TAT for on-site cTnI testing was <50% the TAT for off-site hs-cTnT testing.</p><p><strong>Conclusions: </strong>On-site point-of-care whole blood cTn testing can rapidly confirm significant or late-presenting myocardial injury. Combined with simultaneous off-site high-sensitivity cardiac troponin (hs-cTn) testing, this workflow is a viable interim solution for pediatric hospitals without on-site hs-cTn testing.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfad133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The importance of offering on-site cardiac troponin (cTn) testing at pediatric hospitals may be underappreciated. We developed a rapid rule-in process for myocardial injury at a pediatric hospital experiencing delays in off-site high-sensitivity cardiac troponin T (hs-cTnT) testing.

Methods: Collect-to-verify turnaround times (TATs) for off-site testing were reviewed. Pre-analytic changes to improve TATs were devised, implemented and evaluated, after which a new analyzer was selected and evaluated for on-site cTn testing. Performance of the new analyzer's assay was compared to the off-site hs-cTnT assay, and post go-live TATs for on-site testing were assessed.

Results: Median collect-to-verify TAT for short turnaround-time (STAT) priority off-site plasma hs-cTnT testing was 104 min, with 35% of orders having a TAT >120 min. Eliminating serum separator tubes and requiring a separate plasma separator tube did not significantly reduce TATs. A QuidelOrtho Triage® MeterPro whole blood cardiac troponin I (cTnI) assay was implemented to "triage" time-critical and STAT priority specimens collected for off-site hs-cTnT testing. Elevated cTnI (≥0.02 µg/L) had a sensitivity of 91% for clear elevations in hs-cTnT (≥53 ng/L) but a 0% sensitivity for modest elevations (5 to 13 ng/L, 14 to 52 ng/L). An interpretive comment was auto-appended to cTnI results indicating that clinicians should wait for the hs-cTnT result if cTnI was normal. Median collect-to-verify TAT for on-site cTnI testing was <50% the TAT for off-site hs-cTnT testing.

Conclusions: On-site point-of-care whole blood cTn testing can rapidly confirm significant or late-presenting myocardial injury. Combined with simultaneous off-site high-sensitivity cardiac troponin (hs-cTn) testing, this workflow is a viable interim solution for pediatric hospitals without on-site hs-cTn testing.

全血心肌肌钙蛋白 "分流 "改善儿科医院心肌损伤的早期检测。
背景:在儿科医院提供现场心肌肌钙蛋白(cTn)检测的重要性可能未得到充分重视。一家儿科医院在进行非现场高敏心肌肌钙蛋白 T(hs-cTnT)检测时出现延误,我们为此开发了一套快速排除心肌损伤的流程:方法:对异地检测从采集到验证的周转时间(TAT)进行了审查。方法:对非现场检测的收集到核实的周转时间(TAT)进行了审查,设计、实施和评估了改进 TAT 的分析前变化,随后选择了一台新的分析仪,并对其进行了现场 cTn 检测评估。将新分析仪的检测性能与非现场 hs-cTnT 检测进行了比较,并对现场检测的上线后 TAT 进行了评估:结果:短周转时间(STAT)优先场外血浆 hs-cTnT 检测从采集到验证的中位 TAT 为 104 分钟,35% 的订单 TAT >120 分钟。取消血清分离管和要求使用单独的血浆分离管并不能显著缩短 TAT。采用 QuidelOrtho Triage® MeterPro 全血心肌肌钙蛋白 I (cTnI) 检测法对收集的时间紧迫和 STAT 优先标本进行 "分流",以便进行异地 hs-cTnT 检测。cTnI 升高(≥0.02 µg/L)对 hs-cTnT 明显升高(≥53 ng/L)的灵敏度为 91%,但对轻度升高(5 至 13 ng/L,14 至 52 ng/L)的灵敏度为 0%。cTnI 结果自动添加了解释性注释,指出如果 cTnI 正常,临床医生应等待 hs-cTnT 结果。现场 cTnI 检测从采集到验证的中位 TAT 为结论:现场护理点全血 cTn 检测可快速确认严重或晚期心肌损伤。结合同时进行的非现场高敏心肌肌钙蛋白(hs-cTn)检测,对于没有现场 hs-cTn 检测的儿科医院来说,这种工作流程是一种可行的临时解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Laboratory Medicine
Journal of Applied Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
3.70
自引率
5.00%
发文量
137
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信