{"title":"Comparative study of ventilation techniques with supraglottic airway devices in cats: volume-controlled vs pressure-controlled techniques.","authors":"Nutawan Niyatiwatchanchai, Hathaipat Rattanathanya, Naris Thengchaisri","doi":"10.1177/1098612X231225353","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study compared the effectiveness of a new supraglottic airway device (SGAD) in cats undergoing anaesthesia using two types of mechanical ventilation: volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV).</p><p><strong>Methods: </strong>A total of 13 healthy cats (five male, eight female; median age 2 years [range 1-3]) were randomly allocated to either VCV or PCV. Five tidal volumes (6, 8, 10, 12 and 14 ml/kg) and five peak inspiratory pressures (4, 5, 6, 7 and 8 cmH<sub>2</sub>O) were randomly applied with a minute ventilation of 100 ml/kg/min. Various parameters, such as blood pressure, gas leakage, end-tidal CO<sub>2</sub> (ETCO<sub>2</sub>) and work of breathing (WOB), were measured while using VCV or PCV.</p><p><strong>Results: </strong>The occurrence of hypotension (mean arterial blood pressure <60 mmHg) was slightly less frequent with VCV (38 events, 65 ventilating sessions) than with PCV (40 events, 65 ventilating sessions), but this difference did not reach statistical significance (<i>P</i> = 0.429). The number of leakages did not differ between the VCV group (3 events, 65 ventilating sessions) and the PCV group (3 events, 65 ventilating sessions) (<i>P</i> = 1.000). Hypercapnia was identified when using VCV (10 events, 65 ventilating sessions) less frequently than when using PCV (17 events, 65 ventilating sessions), but this difference did not reach statistical significance (<i>P</i> = 0.194). The study found a significantly higher WOB in the PCV group compared with the VCV group (<i>P</i> <0.034).</p><p><strong>Conclusions and relevance: </strong>The present results suggested that both VCV and PCV can be used with an SGAD during anaesthesia, with VCV preferred for prolonged mechanical ventilation due to its lower workload. Adjusting tidal volume or inspiratory pressure corrects hypercapnia.</p>","PeriodicalId":15851,"journal":{"name":"Journal of Feline Medicine and Surgery","volume":"26 1","pages":"1098612X231225353"},"PeriodicalIF":1.9000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10949876/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Feline Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1177/1098612X231225353","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: This study compared the effectiveness of a new supraglottic airway device (SGAD) in cats undergoing anaesthesia using two types of mechanical ventilation: volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV).
Methods: A total of 13 healthy cats (five male, eight female; median age 2 years [range 1-3]) were randomly allocated to either VCV or PCV. Five tidal volumes (6, 8, 10, 12 and 14 ml/kg) and five peak inspiratory pressures (4, 5, 6, 7 and 8 cmH2O) were randomly applied with a minute ventilation of 100 ml/kg/min. Various parameters, such as blood pressure, gas leakage, end-tidal CO2 (ETCO2) and work of breathing (WOB), were measured while using VCV or PCV.
Results: The occurrence of hypotension (mean arterial blood pressure <60 mmHg) was slightly less frequent with VCV (38 events, 65 ventilating sessions) than with PCV (40 events, 65 ventilating sessions), but this difference did not reach statistical significance (P = 0.429). The number of leakages did not differ between the VCV group (3 events, 65 ventilating sessions) and the PCV group (3 events, 65 ventilating sessions) (P = 1.000). Hypercapnia was identified when using VCV (10 events, 65 ventilating sessions) less frequently than when using PCV (17 events, 65 ventilating sessions), but this difference did not reach statistical significance (P = 0.194). The study found a significantly higher WOB in the PCV group compared with the VCV group (P <0.034).
Conclusions and relevance: The present results suggested that both VCV and PCV can be used with an SGAD during anaesthesia, with VCV preferred for prolonged mechanical ventilation due to its lower workload. Adjusting tidal volume or inspiratory pressure corrects hypercapnia.
期刊介绍:
JFMS is an international, peer-reviewed journal aimed at both practitioners and researchers with an interest in the clinical veterinary healthcare of domestic cats. The journal is published monthly in two formats: ‘Classic’ editions containing high-quality original papers on all aspects of feline medicine and surgery, including basic research relevant to clinical practice; and dedicated ‘Clinical Practice’ editions primarily containing opinionated review articles providing state-of-the-art information for feline clinicians, along with other relevant articles such as consensus guidelines.