{"title":"Optimization and validation of a suprasystolic brachial cuff-based method for noninvasively estimating central aortic blood pressure","authors":"Xujie Zhang, Yue Wang, Zhaofang Yin, Fuyou Liang","doi":"10.1002/cnm.3806","DOIUrl":null,"url":null,"abstract":"<p>Clinical studies have extensively demonstrated that central aortic blood pressure (CABP) has greater clinical significance in comparison with peripheral blood pressure. Despite the existence of various techniques for noninvasively measuring CABP, the clinical applications of most techniques are hampered by the unsatisfactory accuracy or large variability in measurement errors. In this study, we proposed a new method for noninvasively estimating CABP with improved accuracy and reduced uncertain errors. The main idea was to optimize the estimation of the pulse wave transit time from the aorta to the occluded lumen of the brachial artery under a suprasystolic cuff by identifying and utilizing the characteristic information of the cuff oscillation wave, thereby improving the accuracy and stability of the CABP estimation algorithms under various physiological conditions. The method was firstly developed and verified based on large-scale virtual subject data (<i>n</i> = 800) generated by a computational model of the cardiovascular system coupled to a brachial cuff, and then validated with small-scale in vivo data (<i>n</i> = 34). The estimation errors for the aortic systolic pressure were −0.05 ± 0.63 mmHg in the test group of the virtual subjects and −1.09 ± 3.70 mmHg in the test group of the patients, both demonstrating a good performance. In particular, the estimation errors were found to be insensitive to variations in hemodynamic conditions and cardiovascular properties, manifesting the high robustness of the method. The method may have promising clinical applicability, although further validation studies with larger-scale clinical data remain necessary.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"40 3","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.3806","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Clinical studies have extensively demonstrated that central aortic blood pressure (CABP) has greater clinical significance in comparison with peripheral blood pressure. Despite the existence of various techniques for noninvasively measuring CABP, the clinical applications of most techniques are hampered by the unsatisfactory accuracy or large variability in measurement errors. In this study, we proposed a new method for noninvasively estimating CABP with improved accuracy and reduced uncertain errors. The main idea was to optimize the estimation of the pulse wave transit time from the aorta to the occluded lumen of the brachial artery under a suprasystolic cuff by identifying and utilizing the characteristic information of the cuff oscillation wave, thereby improving the accuracy and stability of the CABP estimation algorithms under various physiological conditions. The method was firstly developed and verified based on large-scale virtual subject data (n = 800) generated by a computational model of the cardiovascular system coupled to a brachial cuff, and then validated with small-scale in vivo data (n = 34). The estimation errors for the aortic systolic pressure were −0.05 ± 0.63 mmHg in the test group of the virtual subjects and −1.09 ± 3.70 mmHg in the test group of the patients, both demonstrating a good performance. In particular, the estimation errors were found to be insensitive to variations in hemodynamic conditions and cardiovascular properties, manifesting the high robustness of the method. The method may have promising clinical applicability, although further validation studies with larger-scale clinical data remain necessary.
期刊介绍:
All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.