Costs involved in compliance with new endoscope reprocessing guidelines.

IF 2.1 Q3 GASTROENTEROLOGY & HEPATOLOGY
Clinical Endoscopy Pub Date : 2024-07-01 Epub Date: 2024-01-26 DOI:10.5946/ce.2023.164
David Hoffman, Christina Cool
{"title":"Costs involved in compliance with new endoscope reprocessing guidelines.","authors":"David Hoffman, Christina Cool","doi":"10.5946/ce.2023.164","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>In March 2022, the Association for the Advancement of Medical Instrumentation (AAMI) released the American National Standards Institute (ANSI)/AAMI ST91:2021, their latest update on comprehensive, flexible, and semirigid endoscope reprocessing. These updated standards recommend the sterilization of high-risk endoscopes when possible and provide new recommendations for the precleaning, leak testing, manual cleaning, visual inspection, automated reprocessing, drying, storage, and transport of endoscopes.</p><p><strong>Methods: </strong>ANSI/AAMI ST91:2021 was compared with ANSI/AAMI ST91:2015 for major reprocessing differences that result in either time and/or cost increases. Time estimates were captured by explicit recommendation inclusion or taken from the literature. All the costs were estimated using publicly available resources.</p><p><strong>Results: </strong>The updated standards represent a potential 24.3-minute and 52.35 to 67.57 United States dollars increase per procedure in terms of reprocessing time and spending, respectively, not including capital investments. Capital costs per procedure were highly dependent on the procedure volume of the facility.</p><p><strong>Conclusions: </strong>The new AAMI standards recommend several major changes, such as sterilization, for facilities to reprocess and manage endoscopes between uses. As more facilities increase their reprocessing methods to reflect the updated standards, they do so at a cost and introduce several delays. As the reprocessing landscape evolves, facilities should consider their true costs and alternative solutions, such as single-use endoscopes.</p>","PeriodicalId":10351,"journal":{"name":"Clinical Endoscopy","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11294847/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5946/ce.2023.164","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background/aims: In March 2022, the Association for the Advancement of Medical Instrumentation (AAMI) released the American National Standards Institute (ANSI)/AAMI ST91:2021, their latest update on comprehensive, flexible, and semirigid endoscope reprocessing. These updated standards recommend the sterilization of high-risk endoscopes when possible and provide new recommendations for the precleaning, leak testing, manual cleaning, visual inspection, automated reprocessing, drying, storage, and transport of endoscopes.

Methods: ANSI/AAMI ST91:2021 was compared with ANSI/AAMI ST91:2015 for major reprocessing differences that result in either time and/or cost increases. Time estimates were captured by explicit recommendation inclusion or taken from the literature. All the costs were estimated using publicly available resources.

Results: The updated standards represent a potential 24.3-minute and 52.35 to 67.57 United States dollars increase per procedure in terms of reprocessing time and spending, respectively, not including capital investments. Capital costs per procedure were highly dependent on the procedure volume of the facility.

Conclusions: The new AAMI standards recommend several major changes, such as sterilization, for facilities to reprocess and manage endoscopes between uses. As more facilities increase their reprocessing methods to reflect the updated standards, they do so at a cost and introduce several delays. As the reprocessing landscape evolves, facilities should consider their true costs and alternative solutions, such as single-use endoscopes.

遵守新的内窥镜再处理准则所涉及的成本。
背景/目的:2022 年 3 月,美国医疗器械促进协会 (AAMI) 发布了美国国家标准学会 (ANSI)/AAMI ST91:2021,这是他们对综合、柔性和半刚性内窥镜再处理的最新更新。这些更新的标准建议在可能的情况下对高风险内窥镜进行消毒,并对内窥镜的预清洁、泄漏测试、手动清洁、目视检查、自动再处理、干燥、储存和运输提供了新的建议:方法:将 ANSI/AAMI ST91:2021 与 ANSI/AAMI ST91:2015 进行比较,找出导致时间和/或成本增加的主要再处理差异。时间估算通过明确的建议纳入或从文献中获取。所有成本均使用公开资源进行估算:结果:更新后的标准意味着每个程序的后处理时间和成本(不包括资本投资)可能分别增加 24.3 分钟和 52.35 美元至 67.57 美元。每个程序的资本成本在很大程度上取决于设备的程序量:结论:AAMI 新标准建议进行几项重大改革,例如消毒,以便医疗机构在内窥镜使用之间进行再处理和管理。随着越来越多的医疗机构增加其再处理方法以反映更新的标准,他们为此付出了成本,并造成了一些延误。随着后处理技术的发展,医疗机构应考虑其实际成本和替代解决方案,如一次性内窥镜。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Endoscopy
Clinical Endoscopy GASTROENTEROLOGY & HEPATOLOGY-
CiteScore
4.40
自引率
8.00%
发文量
95
审稿时长
26 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信