Impact of Angle of File Access and Location of Canal Curvature on the Dynamic Cyclic Fatigue of Nickel Titanium Rotary Instruments.

IF 1.6 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
European Endodontic Journal Pub Date : 2024-03-08 Epub Date: 2024-01-24 DOI:10.14744/eej.2023.71676
Dina Assaf, Mohammed Abou El Seoud, Mohammed Kataia, Shehabeldin Saber
{"title":"Impact of Angle of File Access and Location of Canal Curvature on the Dynamic Cyclic Fatigue of Nickel Titanium Rotary Instruments.","authors":"Dina Assaf, Mohammed Abou El Seoud, Mohammed Kataia, Shehabeldin Saber","doi":"10.14744/eej.2023.71676","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the impact of different file access angles and root canal curvature's location on the fatigue failure of One Curve (OC) and E3 Azure (EZ) NiTi files using a dynamic model at simulated body temperature.</p><p><strong>Methods: </strong>Eighty new instruments with similar tip sizes and taper (#25/0.06) from two NiTi rotary systems, One Curve and E3 Azure, were tested at simulated body temperatures (37°C) using a custom-made dynamic cyclic fatigue device. Instruments were divided into four subgroups according to the location of root canal curvature (a coronal curve 5 mm from the root canal orifice and an apical curve 10 mm from the root canal orifice) and the angle of file access (0° or 30°). Instruments were operated in simulated stainless-steel canals having a 60° curve and a 3 mm radius. A custom-made device produced controlled vertical pecks during file rotation. Time to failure (sec) was registered, and the length of the fragment segments was measured (mm). Data were analysed statistically with One-Way ANOVA and Tukey post hoc tests. The significance level was set at 5%. All separated instruments were examined by scanning electron microscope.</p><p><strong>Results: </strong>One-way ANOVA (p<0.05) found a significant difference among the tested instruments. Post Hoc analysis revealed lower cyclic fatigue resistance when the angle of file access was 30º, and the root canal curvature was located coronally for both files (p<0.0001). Three-way ANOVA showed that the angle of file access was the most influential contributor to cyclic fatigue, followed by the location of file curvature and, finally, the file type (p<0.0001). The fractographic examination revealed a predominantly ductile fracture mode for all tested instruments. The lengths of all fractured segments showed no significant difference (p>0.05), indicating an accurate trajectory during testing.</p><p><strong>Conclusion: </strong>OC files had superior cyclic fatigue resistance than EZ files; coronal curvatures negatively impacted cyclic fatigue resistance compared to apical curvatures, while the angle of file access presented the highest impact on dynamic cyclic fatigue.</p>","PeriodicalId":11860,"journal":{"name":"European Endodontic Journal","volume":" ","pages":"133 - 138"},"PeriodicalIF":1.6000,"publicationDate":"2024-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10938357/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/eej.2023.71676","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the impact of different file access angles and root canal curvature's location on the fatigue failure of One Curve (OC) and E3 Azure (EZ) NiTi files using a dynamic model at simulated body temperature.

Methods: Eighty new instruments with similar tip sizes and taper (#25/0.06) from two NiTi rotary systems, One Curve and E3 Azure, were tested at simulated body temperatures (37°C) using a custom-made dynamic cyclic fatigue device. Instruments were divided into four subgroups according to the location of root canal curvature (a coronal curve 5 mm from the root canal orifice and an apical curve 10 mm from the root canal orifice) and the angle of file access (0° or 30°). Instruments were operated in simulated stainless-steel canals having a 60° curve and a 3 mm radius. A custom-made device produced controlled vertical pecks during file rotation. Time to failure (sec) was registered, and the length of the fragment segments was measured (mm). Data were analysed statistically with One-Way ANOVA and Tukey post hoc tests. The significance level was set at 5%. All separated instruments were examined by scanning electron microscope.

Results: One-way ANOVA (p<0.05) found a significant difference among the tested instruments. Post Hoc analysis revealed lower cyclic fatigue resistance when the angle of file access was 30º, and the root canal curvature was located coronally for both files (p<0.0001). Three-way ANOVA showed that the angle of file access was the most influential contributor to cyclic fatigue, followed by the location of file curvature and, finally, the file type (p<0.0001). The fractographic examination revealed a predominantly ductile fracture mode for all tested instruments. The lengths of all fractured segments showed no significant difference (p>0.05), indicating an accurate trajectory during testing.

Conclusion: OC files had superior cyclic fatigue resistance than EZ files; coronal curvatures negatively impacted cyclic fatigue resistance compared to apical curvatures, while the angle of file access presented the highest impact on dynamic cyclic fatigue.

锉刀切入角度和管道曲率位置对镍钛旋转仪器动态循环疲劳的影响
目的使用模拟体温下的动态模型,评估不同的锉接入角度和根管曲率位置对One Curve(OC)和E3 Azure(EZ)镍钛锉疲劳失效的影响:使用定制的动态循环疲劳装置,在模拟体温(37°C)下对两种镍钛旋转系统(One Curve 和 E3 Azure)的 80 个具有相似尖端尺寸和锥度(25/0.06 号)的新器械进行了测试。根据根管弯曲的位置(距离根管口 5 毫米的冠状曲线和距离根管口 10 毫米的根尖曲线)和锉刀进入的角度(0° 或 30°),将器械分为四个亚组。仪器在半径为 3 毫米、弯曲度为 60° 的模拟不锈钢根管中操作。在锉旋转过程中,一个定制的装置会产生受控的垂直啄击。记录失效时间(秒),并测量片段的长度(毫米)。数据采用单向方差分析和 Tukey 事后检验进行统计分析。显著性水平设定为 5%。用扫描电子显微镜检查所有分离的仪器:单因子方差分析(P0.05)表明测试过程中轨迹准确:OC锉的抗循环疲劳性优于EZ锉;与根尖弧度相比,冠状弧度对抗循环疲劳性有负面影响,而锉刀进入的角度对动态循环疲劳的影响最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Endodontic Journal
European Endodontic Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.40
自引率
5.60%
发文量
25
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信