{"title":"Toward improved thermal exposure classes for structural firefighters","authors":"C. Weinschenk, Holli Knight, John W Regan","doi":"10.1177/07349041231222852","DOIUrl":null,"url":null,"abstract":"In the early 1970s, there was an initial effort to quantify the conditions under which firefighters are expected to perform. Harvey Utech led this endeavor by defining three levels of thermal exposure—routine, ordinary, and emergency—which were characterized by combining a range of air temperatures and radiative heat fluxes. In the last half-century, there has been a concerted scientific effort to further understand the conditions to which firefighters are exposed during structural firefighting. Research has been conducted on the resiliency of turnout gear and facepiece lenses, the thermal conditions observed during a structure fire, and the impact of firefighter tactics such as ventilation and suppression. The authors synthesize the results from these research areas to update the original thermal classifications to six categories of exposure—routine, Ordinary I, Ordinary II, Emergency I, Emergency II, and Emergency III—which are more representative of the operating environment and protective equipment thresholds that firefighters should be aware of during firefighting operations and tactical decision-making.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/07349041231222852","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
In the early 1970s, there was an initial effort to quantify the conditions under which firefighters are expected to perform. Harvey Utech led this endeavor by defining three levels of thermal exposure—routine, ordinary, and emergency—which were characterized by combining a range of air temperatures and radiative heat fluxes. In the last half-century, there has been a concerted scientific effort to further understand the conditions to which firefighters are exposed during structural firefighting. Research has been conducted on the resiliency of turnout gear and facepiece lenses, the thermal conditions observed during a structure fire, and the impact of firefighter tactics such as ventilation and suppression. The authors synthesize the results from these research areas to update the original thermal classifications to six categories of exposure—routine, Ordinary I, Ordinary II, Emergency I, Emergency II, and Emergency III—which are more representative of the operating environment and protective equipment thresholds that firefighters should be aware of during firefighting operations and tactical decision-making.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.