The Ability of Antibody against Truncated Matrix Metalloproteinase 9 Peptide to Evaluate the Native Protein on Tear Drops of Dry Eye Disease Patients by a Point-of-Care Diagnostic System.

IF 1.2 Q3 OPHTHALMOLOGY
Journal of Current Ophthalmology Pub Date : 2023-12-21 eCollection Date: 2023-04-01 DOI:10.4103/joco.joco_320_22
Zahra Afshari, Mohammad Javad Rasaee, Maliheh Paknejad, Saeed Khalili, Alireza Baradaran-Rafii
{"title":"The Ability of Antibody against Truncated Matrix Metalloproteinase 9 Peptide to Evaluate the Native Protein on Tear Drops of Dry Eye Disease Patients by a Point-of-Care Diagnostic System.","authors":"Zahra Afshari, Mohammad Javad Rasaee, Maliheh Paknejad, Saeed Khalili, Alireza Baradaran-Rafii","doi":"10.4103/joco.joco_320_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To obtain a reactive and specific antibody against truncated matrix metalloproteinase 9 (MMP-9), that has reactivity toward the native protein. Precision, accuracy, specificity, and sensitivity were evaluated using a point-of-care test.</p><p><strong>Methods: </strong>An <i>in silico</i> study was used to confirm the anti peptide truncated MMP-9 is against native MMP-9. After an antibody titer assessment, purification, and characterization, the anti MMP-9 was assessed. The cut-off value was determined using the purified gelatinases of the supernatant HCT 116 cell line. The supernatant was purified by preparative native-polyacrylamide gel electrophoresis based on charge and size of the proteins. Furthermore, quality control (QC) of the results were performed following standard densitometry methods.</p><p><strong>Results: </strong>A truncated MMP-9 is the major epitope peptide that can trigger the immune system to scavenge for a specific and reactive antibody against the native MMP-9. The MMP-9 native protein is purified from the supernatant of the HCT 116 cell line and the commercially available, full-length MMP-9. The cut-off value was estimated at 30 μg/mL. QC results indicated that the specificity was 80%, sensitivity was 96.7%, accuracy was 91%, and precision was 91.66%. The area under curve was 0.827 (<i>P</i> < 0.001). The positive predictive value was 83%, and the negative predictive value was 96%.</p><p><strong>Conclusions: </strong>The antibody against the synthetic epitope peptide can detect the native MMP-9. Native MMP-9 is considered the main biomarker in an immunoassay POCT and is used to diagnose dry eye disease (DED). In accordance with QC results, MMP-9 point of care test can be utilized for screening patients suffering from DED.</p>","PeriodicalId":15423,"journal":{"name":"Journal of Current Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10795817/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Current Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/joco.joco_320_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To obtain a reactive and specific antibody against truncated matrix metalloproteinase 9 (MMP-9), that has reactivity toward the native protein. Precision, accuracy, specificity, and sensitivity were evaluated using a point-of-care test.

Methods: An in silico study was used to confirm the anti peptide truncated MMP-9 is against native MMP-9. After an antibody titer assessment, purification, and characterization, the anti MMP-9 was assessed. The cut-off value was determined using the purified gelatinases of the supernatant HCT 116 cell line. The supernatant was purified by preparative native-polyacrylamide gel electrophoresis based on charge and size of the proteins. Furthermore, quality control (QC) of the results were performed following standard densitometry methods.

Results: A truncated MMP-9 is the major epitope peptide that can trigger the immune system to scavenge for a specific and reactive antibody against the native MMP-9. The MMP-9 native protein is purified from the supernatant of the HCT 116 cell line and the commercially available, full-length MMP-9. The cut-off value was estimated at 30 μg/mL. QC results indicated that the specificity was 80%, sensitivity was 96.7%, accuracy was 91%, and precision was 91.66%. The area under curve was 0.827 (P < 0.001). The positive predictive value was 83%, and the negative predictive value was 96%.

Conclusions: The antibody against the synthetic epitope peptide can detect the native MMP-9. Native MMP-9 is considered the main biomarker in an immunoassay POCT and is used to diagnose dry eye disease (DED). In accordance with QC results, MMP-9 point of care test can be utilized for screening patients suffering from DED.

用护理点诊断系统评估针对截短基质金属蛋白酶 9 肽的抗体在干眼症患者滴泪液中检测原生蛋白的能力。
目的:获得针对截短基质金属蛋白酶 9(MMP-9)的特异性反应性抗体,该抗体对原生蛋白有反应性。方法:采用一种床旁检测方法对精确度、准确性、特异性和灵敏度进行评估:方法:采用了一项硅学研究来确认抗肽截短 MMP-9 是针对原生 MMP-9。经过抗体滴度评估、纯化和特征描述后,对抗 MMP-9 进行了评估。使用 HCT 116 细胞系上清液中纯化的明胶酶确定截止值。根据蛋白质的电荷和大小,通过制备原生聚丙烯酰胺凝胶电泳对上清液进行纯化。此外,还按照标准密度计方法对结果进行了质量控制(QC):截短的MMP-9是主要的表位肽,可引发免疫系统清除针对原生MMP-9的特异性反应抗体。MMP-9 原生蛋白是从 HCT 116 细胞系的上清液和市售的全长 MMP-9 中纯化出来的。临界值估计为 30 μg/mL。质控结果表明,特异性为 80%,灵敏度为 96.7%,准确度为 91%,精确度为 91.66%。曲线下面积为 0.827(P < 0.001)。阳性预测值为 83%,阴性预测值为 96%:结论:针对合成表位肽的抗体可以检测出原生 MMP-9。原生 MMP-9 被认为是免疫测定 POCT 的主要生物标记物,可用于诊断干眼症(DED)。根据质控结果,MMP-9 护理点检测可用于筛查 DED 患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
6.70%
发文量
45
审稿时长
8 weeks
期刊介绍: Peer Review under the responsibility of Iranian Society of Ophthalmology Journal of Current Ophthalmology, the official publication of the Iranian Society of Ophthalmology, is a peer-reviewed, open-access, scientific journal that welcomes high quality original articles related to vision science and all fields of ophthalmology. Journal of Current Ophthalmology is the continuum of Iranian Journal of Ophthalmology published since 1969.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信