{"title":"Azalea Petal-Derived Porous Carbon–Thionine Based Ratiometric Electrochemical Sensor for the Simultaneous Determination of Ascorbic Acid and Uric Acid","authors":"Biao Jin, Shanshan Liu, Dongri Jin","doi":"10.1134/s1023193523220032","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Abstract</h3><p>The design of the electrode materials for electrochemical sensors is crucial for the simultaneous fast detection of ascorbic acid (AA) and uric acid (UA). A hierarchical porous carbon material (KACM) was prepared via high-temperature calcination and KOH activation using azalea (a species of rhododendron) biomass as the carbon source. KACM and thionine (Thi) were simultaneously assembled on a glassy carbon electrode (GCE) to construct a porous carbon/thionine ratiometric electrochemical biosensor for the detection of ascorbic acid and uric acid. Electrochemical evaluation showed that the Thi/KACM/GCE has good electrochemical performance, strong catalytic activity toward AA and UA oxidation, and good separation of the two oxidation peaks. Under the optimized conditions, Thi/KACM/GCE has a wide linear range (0.05–9 mM) and low detection limit (6.4 μM for AA and 10 μM for UA). Additionally, the biosensor exhibited good selectivity, stability, and reproducibility. Thi/KACM/GCE was used for the simultaneous detection of AA and UA in human urine with 99.4–101.0% recovery of the compounds. This study reports for the first time the use of azaleas in electrochemical biosensors, and the results show that small changes in the structural properties of biomass materials can affect their electrochemical properties.</p>","PeriodicalId":760,"journal":{"name":"Russian Journal of Electrochemistry","volume":"34 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Journal of Electrochemistry","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1134/s1023193523220032","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

Abstract

The design of the electrode materials for electrochemical sensors is crucial for the simultaneous fast detection of ascorbic acid (AA) and uric acid (UA). A hierarchical porous carbon material (KACM) was prepared via high-temperature calcination and KOH activation using azalea (a species of rhododendron) biomass as the carbon source. KACM and thionine (Thi) were simultaneously assembled on a glassy carbon electrode (GCE) to construct a porous carbon/thionine ratiometric electrochemical biosensor for the detection of ascorbic acid and uric acid. Electrochemical evaluation showed that the Thi/KACM/GCE has good electrochemical performance, strong catalytic activity toward AA and UA oxidation, and good separation of the two oxidation peaks. Under the optimized conditions, Thi/KACM/GCE has a wide linear range (0.05–9 mM) and low detection limit (6.4 μM for AA and 10 μM for UA). Additionally, the biosensor exhibited good selectivity, stability, and reproducibility. Thi/KACM/GCE was used for the simultaneous detection of AA and UA in human urine with 99.4–101.0% recovery of the compounds. This study reports for the first time the use of azaleas in electrochemical biosensors, and the results show that small changes in the structural properties of biomass materials can affect their electrochemical properties.

Abstract Image

基于杜鹃花瓣的多孔碳-硫氨酸比率电化学传感器用于同时测定抗坏血酸和尿酸
摘要 电化学传感器电极材料的设计对于同时快速检测抗坏血酸(AA)和尿酸(UA)至关重要。以杜鹃花生物质为碳源,通过高温煅烧和 KOH 活化制备了一种分层多孔碳材料(KACM)。将 KACM 和亚硫酸(Thi)同时组装在玻璃碳电极(GCE)上,构建了一种用于检测抗坏血酸和尿酸的多孔碳/亚硫酸比率电化学生物传感器。电化学评价结果表明,Thi/KACM/GCE具有良好的电化学性能,对AA和UA的氧化具有很强的催化活性,并能很好地分离两个氧化峰。在优化条件下,Thi/KACM/GCE 具有较宽的线性范围(0.05-9 mM)和较低的检测限(AA 为 6.4 μM,UA 为 10 μM)。此外,该生物传感器还具有良好的选择性、稳定性和再现性。Thi/KACM/GCE 被用于同时检测人体尿液中的 AA 和 UA,化合物回收率为 99.4-101.0%。该研究首次报道了杜鹃花在电化学生物传感器中的应用,结果表明生物质材料结构特性的微小变化都会影响其电化学特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Russian Journal of Electrochemistry
Russian Journal of Electrochemistry 工程技术-电化学
CiteScore
1.90
自引率
8.30%
发文量
102
审稿时长
6 months
期刊介绍: Russian Journal of Electrochemistry is a journal that covers all aspects of research in modern electrochemistry. The journal welcomes submissions in English or Russian regardless of country and nationality of authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信