Birmingham hip resurfacing: a systematic review of outcomes at minimum 10-years follow-up.

IF 0.5 4区 医学 Q4 ORTHOPEDICS
M S Davey, K Mohan, E Gavin, F R Power, W Curtin, K Kaar, C G Murphy
{"title":"Birmingham hip resurfacing: a systematic review of outcomes at minimum 10-years follow-up.","authors":"M S Davey, K Mohan, E Gavin, F R Power, W Curtin, K Kaar, C G Murphy","doi":"10.52628/89.4.10045","DOIUrl":null,"url":null,"abstract":"<p><p>Although controversy surrounding the use of metal-on-metal (MoM) arthroplasty implants continues to exist, satisfactory clinical and radiological outcomes have been reported following Birmingham Hip Resurfacing (BHR) at long-term follow-up, leading to an Orthopaedic Data Evaluation Panel (ODEP) rating of 13A. The purpose of this study was to systematically review the literature to evaluate the functional outcomes, radiological outcomes and revision rates following BHR at a minimum of 10 years follow-up. Using the PRISMA guidelines, two independent reviewers performed a literature search using Pubmed, Embase and Scopus databases. Only studies reporting on outcomes of BHR with a minimum of 10 years' follow-up were considered for inclusion. A total of 12 studies including 7132 hips (64.8% males), with mean follow-up of 11.5 years (10-15.3), met our inclusion criteria. Of included patients, 94.3% of patient underwent BHR for osteoarthritis at a mean age was 52.0 years (48-52). At final follow-up, 96% of patients reported being satisfied with their BHR, with mean Harris Hip Scores of 93.6 and Oxford Hip Scores of 16.5. Rates of radiological femoral neck narrowing of greater than 10% and non-progressive radiological loosening were reported as 2.0% and 3.8% respectively. At final follow-up, the overall revision rate was 4.9% (334/7132), deep infection rate was 0.4%, metal allergy/insensitivity rate was 1.6%, metal reaction rate was 0.3%, rate of peri-prosthetic fracture was 0.9% and aseptic loosening rates were 1.6%. This systematic review demonstrates that BHR results in satisfactory clinical outcomes, acceptable implant survivorship, low complication rates and modest surgical revision rates in the long-term at minimum 10-year follow-up.</p>","PeriodicalId":7018,"journal":{"name":"Acta orthopaedica Belgica","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica Belgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52628/89.4.10045","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Although controversy surrounding the use of metal-on-metal (MoM) arthroplasty implants continues to exist, satisfactory clinical and radiological outcomes have been reported following Birmingham Hip Resurfacing (BHR) at long-term follow-up, leading to an Orthopaedic Data Evaluation Panel (ODEP) rating of 13A. The purpose of this study was to systematically review the literature to evaluate the functional outcomes, radiological outcomes and revision rates following BHR at a minimum of 10 years follow-up. Using the PRISMA guidelines, two independent reviewers performed a literature search using Pubmed, Embase and Scopus databases. Only studies reporting on outcomes of BHR with a minimum of 10 years' follow-up were considered for inclusion. A total of 12 studies including 7132 hips (64.8% males), with mean follow-up of 11.5 years (10-15.3), met our inclusion criteria. Of included patients, 94.3% of patient underwent BHR for osteoarthritis at a mean age was 52.0 years (48-52). At final follow-up, 96% of patients reported being satisfied with their BHR, with mean Harris Hip Scores of 93.6 and Oxford Hip Scores of 16.5. Rates of radiological femoral neck narrowing of greater than 10% and non-progressive radiological loosening were reported as 2.0% and 3.8% respectively. At final follow-up, the overall revision rate was 4.9% (334/7132), deep infection rate was 0.4%, metal allergy/insensitivity rate was 1.6%, metal reaction rate was 0.3%, rate of peri-prosthetic fracture was 0.9% and aseptic loosening rates were 1.6%. This systematic review demonstrates that BHR results in satisfactory clinical outcomes, acceptable implant survivorship, low complication rates and modest surgical revision rates in the long-term at minimum 10-year follow-up.

伯明翰髋关节置换术:至少 10 年随访结果的系统性回顾。
尽管围绕金属对金属(MoM)关节置换术植入物的使用仍存在争议,但在伯明翰髋关节置换术(BHR)的长期随访中,临床和放射学结果均令人满意,并被骨科数据评估小组(ODEP)评为 13A。本研究的目的是系统回顾文献,评估 BHR 术后至少 10 年随访的功能效果、放射效果和翻修率。根据 PRISMA 指南,两位独立审稿人使用 Pubmed、Embase 和 Scopus 数据库进行了文献检索。只有报告了 BHR 至少 10 年随访结果的研究才被考虑纳入。共有 12 项研究符合我们的纳入标准,其中包括 7132 个髋关节(64.8% 为男性),平均随访时间为 11.5 年(10-15.3 年)。在纳入的患者中,94.3%的患者因骨关节炎接受了 BHR 治疗,平均年龄为 52.0 岁(48-52 岁)。在最后的随访中,96%的患者表示对他们的BHR满意,平均哈里斯髋关节评分为93.6分,牛津髋关节评分为16.5分。据报道,放射性股骨颈狭窄超过10%和非进行性放射性松动的发生率分别为2.0%和3.8%。在最终随访中,总体翻修率为4.9%(334/7132),深部感染率为0.4%,金属过敏/不敏感率为1.6%,金属反应率为0.3%,假体周围骨折率为0.9%,无菌性松动率为1.6%。这篇系统性综述表明,在至少 10 年的长期随访中,BHR 能带来令人满意的临床效果、可接受的植入体存活率、较低的并发症发生率和适度的手术翻修率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta orthopaedica Belgica
Acta orthopaedica Belgica 医学-整形外科
CiteScore
0.70
自引率
0.00%
发文量
58
审稿时长
4-8 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信