Sudden Commencements and Geomagnetically Induced Currents in New Zealand: Correlations and Dependance

IF 3.7 2区 地球科学
Space Weather Pub Date : 2024-01-10 DOI:10.1029/2023sw003731
A. W. Smith, C. J. Rodger, D. H. Mac Manus, I. J. Rae, A. R. Fogg, C. Forsyth, P. Fisher, T. Petersen, M. Dalzell
{"title":"Sudden Commencements and Geomagnetically Induced Currents in New Zealand: Correlations and Dependance","authors":"A. W. Smith, C. J. Rodger, D. H. Mac Manus, I. J. Rae, A. R. Fogg, C. Forsyth, P. Fisher, T. Petersen, M. Dalzell","doi":"10.1029/2023sw003731","DOIUrl":null,"url":null,"abstract":"Changes in the Earth's geomagnetic field induce geoelectric fields in the solid Earth. These electric fields drive Geomagnetically Induced Currents (GICs) in grounded, conducting infrastructure. These GICs can damage or degrade equipment if they are sufficiently intense—understanding and forecasting them is of critical importance. One of the key magnetospheric phenomena are Sudden Commencements (SCs). To examine the potential impact of SCs we evaluate the correlation between the measured maximum GICs and rate of change of the magnetic field (<i>H</i>′) in 75 power grid transformers across New Zealand between 2001 and 2020. The maximum observed <i>H</i>′ and GIC correlate well, with correlation coefficients (<i>r</i><sup>2</sup>) around 0.7. We investigate the gradient of the relationship between <i>H</i>′ and GIC, finding a hot spot close to Dunedin: where a given <i>H</i>′ will drive the largest relative current (0.5 A nT<sup>−1</sup> min). We observe strong intralocation variability, with the gradients varying by a factor of two or more at adjacent transformers. We find that GICs are (on average) greater if they are related to: (a) Storm Sudden Commencements (SSCs; 27% larger than Sudden Impulses, SIs); (b) SCs while New Zealand is on the dayside of the Earth (27% larger than the nightside); and (c) SCs with a predominantly East-West magnetic field change (14% larger than North-South equivalents). These results are attributed to the geology of New Zealand and the geometry of the power network. We extrapolate to find that transformers near Dunedin would see 2000 A or more during a theoretical extreme SC (<i>H</i>′ = 4000 nT min<sup>−1</sup>).","PeriodicalId":22181,"journal":{"name":"Space Weather","volume":"21 1","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2024-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Space Weather","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1029/2023sw003731","RegionNum":2,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Changes in the Earth's geomagnetic field induce geoelectric fields in the solid Earth. These electric fields drive Geomagnetically Induced Currents (GICs) in grounded, conducting infrastructure. These GICs can damage or degrade equipment if they are sufficiently intense—understanding and forecasting them is of critical importance. One of the key magnetospheric phenomena are Sudden Commencements (SCs). To examine the potential impact of SCs we evaluate the correlation between the measured maximum GICs and rate of change of the magnetic field (H′) in 75 power grid transformers across New Zealand between 2001 and 2020. The maximum observed H′ and GIC correlate well, with correlation coefficients (r2) around 0.7. We investigate the gradient of the relationship between H′ and GIC, finding a hot spot close to Dunedin: where a given H′ will drive the largest relative current (0.5 A nT−1 min). We observe strong intralocation variability, with the gradients varying by a factor of two or more at adjacent transformers. We find that GICs are (on average) greater if they are related to: (a) Storm Sudden Commencements (SSCs; 27% larger than Sudden Impulses, SIs); (b) SCs while New Zealand is on the dayside of the Earth (27% larger than the nightside); and (c) SCs with a predominantly East-West magnetic field change (14% larger than North-South equivalents). These results are attributed to the geology of New Zealand and the geometry of the power network. We extrapolate to find that transformers near Dunedin would see 2000 A or more during a theoretical extreme SC (H′ = 4000 nT min−1).
新西兰的突发事件和地磁诱导流:相关性和依赖性
地球地磁场的变化会在固体地球中产生地电场。这些电场会在接地的导电基础设施中产生地磁诱导电流(GIC)。如果这些地磁诱导电流强度足够大,就会损坏设备或使设备性能下降,因此了解和预测这些地磁诱导电流至关重要。磁层的关键现象之一是突然启动(SC)。为了研究骤变的潜在影响,我们评估了 2001 年至 2020 年期间新西兰 75 个电网变压器中测得的最大 GIC 与磁场变化率(H′)之间的相关性。观测到的最大 H′与 GIC 相关性良好,相关系数 (r2) 约为 0.7。我们研究了 H′和 GIC 之间的梯度关系,发现了一个靠近但尼丁的热点区域:在该区域,给定的 H′将驱动最大的相对电流(0.5 A nT-1 min)。我们观察到强烈的位置内变化,相邻变压器的梯度相差两倍或更多。我们发现,如果 GIC 与以下情况有关,则 GIC(平均)更大:(a) 风暴突变(SSCs;比突变脉冲(SIs)大 27%);(b) 新西兰处于地球日侧时的突变(比夜侧大 27%);以及 (c) 主要为东西磁场变化的突变(比南北磁场变化大 14%)。这些结果归因于新西兰的地质和电力网络的几何形状。我们推断,达尼丁附近的变压器在理论上的极端 SC(H′ = 4000 nT min-1)期间会出现 2000 A 或更大的电流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
29.70%
发文量
166
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信