Validation and Calibration for Embedding Rating of Perceived Exertion Into High-Intensity Interval Exercise in Adolescents: A Lab-Based Study.

IF 1.4 4区 医学 Q3 PEDIATRICS
Pediatric Exercise Science Pub Date : 2024-01-08 Print Date: 2025-02-01 DOI:10.1123/pes.2023-0084
Yong Liu, Craig A Williams, Kathryn L Weston, Stephanie L Duncombe, Adam A Malik, Alan R Barker
{"title":"Validation and Calibration for Embedding Rating of Perceived Exertion Into High-Intensity Interval Exercise in Adolescents: A Lab-Based Study.","authors":"Yong Liu, Craig A Williams, Kathryn L Weston, Stephanie L Duncombe, Adam A Malik, Alan R Barker","doi":"10.1123/pes.2023-0084","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Rating of perceived exertion (RPE) is a convenient and cost-effective tool that can be used to monitor high-intensity interval exercise (HIIE). However, no methodological study has demonstrated the validity of RPE in this context. Therefore, the aim of this study was to validate and calibrate RPE for monitoring HIIE in adolescents.</p><p><strong>Methods: </strong>RPE, heart rate (HR), and oxygen uptake (V˙O2) data were retrospectively extracted from 3 lab-based crossover studies, with a pooled sample size of 45 adolescents, performing either cycling-based or running-based HIIE sessions. Within-participant correlations were calculated for RPE-HR and RPE-V˙O2, and receiver operator characteristic curve analysis was used to establish RPE cut points.</p><p><strong>Results: </strong>The results showed that RPE-HR demonstrated acceptable criterion validity (r = .53-.74, P < .01), while RPE-V˙O2 had poor validity (r = .40-.48, P < .01), except for HIIE at 100% peak power (r = .59, P < .01). RPE cut points of 4 and 5 were established in corresponding to HR/V˙O2 based thresholds.</p><p><strong>Conclusion: </strong>RPE has some utility in evaluating intensity during lab-based running or cycling HIIE in adolescents. Future studies should expand the validation and calibration of RPE for prescribing and monitoring HIIE in children and adolescents in field-based contexts.</p>","PeriodicalId":49712,"journal":{"name":"Pediatric Exercise Science","volume":" ","pages":"11-17"},"PeriodicalIF":1.4000,"publicationDate":"2024-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Exercise Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1123/pes.2023-0084","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"Print","JCR":"Q3","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Rating of perceived exertion (RPE) is a convenient and cost-effective tool that can be used to monitor high-intensity interval exercise (HIIE). However, no methodological study has demonstrated the validity of RPE in this context. Therefore, the aim of this study was to validate and calibrate RPE for monitoring HIIE in adolescents.

Methods: RPE, heart rate (HR), and oxygen uptake (V˙O2) data were retrospectively extracted from 3 lab-based crossover studies, with a pooled sample size of 45 adolescents, performing either cycling-based or running-based HIIE sessions. Within-participant correlations were calculated for RPE-HR and RPE-V˙O2, and receiver operator characteristic curve analysis was used to establish RPE cut points.

Results: The results showed that RPE-HR demonstrated acceptable criterion validity (r = .53-.74, P < .01), while RPE-V˙O2 had poor validity (r = .40-.48, P < .01), except for HIIE at 100% peak power (r = .59, P < .01). RPE cut points of 4 and 5 were established in corresponding to HR/V˙O2 based thresholds.

Conclusion: RPE has some utility in evaluating intensity during lab-based running or cycling HIIE in adolescents. Future studies should expand the validation and calibration of RPE for prescribing and monitoring HIIE in children and adolescents in field-based contexts.

在青少年高强度间歇运动中嵌入 "知觉消耗量评分 "的验证和校准:一项基于实验室的研究。
目的感知用力值(RPE)是一种方便且具有成本效益的工具,可用于监测高强度间歇运动(HIIE)。然而,还没有方法学研究证明 RPE 在这方面的有效性。因此,本研究旨在验证和校准用于监测青少年高强度间歇运动的 RPE:方法:从 3 项实验室交叉研究中回顾性地提取了 RPE、心率(HR)和摄氧量(V˙O2)数据,这些研究共收集了 45 名青少年的样本量,他们分别进行了以骑自行车或跑步为基础的 HIIE 训练。计算了 RPE-HR 和 RPE-V˙O2 的参与者内相关性,并使用接收器运算特性曲线分析确定了 RPE 切点:结果表明,RPE-HR 具有可接受的标准有效性(r = .53-.74,P < .01),而 RPE-V˙O2 的有效性较差(r = .40-.48,P < .01),100% 峰值功率的 HIIE 除外(r = .59,P < .01)。根据基于 HR/V˙O2 的阈值,确定了 4 和 5 的 RPE 切点:结论:RPE 对于评估青少年在实验室跑步或骑自行车 HIIE 期间的强度具有一定的实用性。今后的研究应扩大 RPE 的验证和校准范围,以便在实地环境中对儿童和青少年的 HIIE 进行处方和监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pediatric Exercise Science
Pediatric Exercise Science 医学-生理学
CiteScore
2.80
自引率
0.00%
发文量
33
审稿时长
>12 weeks
期刊介绍: Pediatric Exercise Science is a journal committed to enriching the scientific knowledge of exercise during childhood and adolescence. To this end it publishes information that contributes to an understanding of (a) the unique aspects of the physiologic, physical, biochemical, and psychologic responses of children to exercise, (b) the role of exercise in the treatment of pediatric chronic diseases, (c) the importance of physical activity in the prevention of illness and preservation of wellness, and (d) the means by which participation in sports may be made safer and more enjoyable for children and youth. Consideration will be given for publication of work by various methodologies consistent with the scientific approach. Besides original research, the journal includes review articles, abstracts from other journals, book reviews, and editorial comments. Pediatric Exercise Science encourages the expression of conflicting opinions regarding children and exercise by providing a forum for alternative viewpoints. At the same time it serves as a means of accumulating a base of research information that will allow application of experimental data to clinical practice. The scientific disciplines contributing to this body of knowledge are diverse. Therefore it is the purpose of this journal to provide a common focus for disseminating advances in the science of exercise during childhood. In doing so, the journal allows the opportunity for cross-fertilization of ideas between disciplines that will potentiate the growth of knowledge in this field. Pediatric Exercise Science seeks to stimulate new ideas regarding exercise in children and to increase the awareness of scientists, health care providers, and physical educators of the importance of exercise during childhood.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信