Cory A. Christensen, Ian A. Thompson, Jared S. Nielsen
{"title":"Small-Gauge Vitrectomy for Macular Surgery Using a Systematic Approach to Wound Closure: 27-Gauge vs 25-Gauge","authors":"Cory A. Christensen, Ian A. Thompson, Jared S. Nielsen","doi":"10.1177/24741264231209587","DOIUrl":null,"url":null,"abstract":"Purpose: To evaluate the effectiveness of and to compare vitrectomy performed with 25-gauge or 27-gauge instrumentation for macular surgery. The surgical duration, wound closure, and complication rate using a systematic approach to wound closure were assessed. Methods: In this retrospective chart review, 125 25-gauge and 125 27-gauge consecutive small-gauge vitrectomy surgeries for epiretinal membrane, macular hole, vitreomacular adhesion, or a combination were analyzed during and immediately after surgery. Wound closure was performed using a systematic protocol. Results: Baseline characteristics were not statistically different between the 2 groups. The surgical duration was similar with 25-gauge vitrectomy and 27-gauge vitrectomy ( P = .07). Although spontaneous wound closure was common in both groups, it was more common in the 27-gauge group ( P = .22). Intraoperative and postoperative complications were uncommon in both groups. Conclusions: Findings show that 27-gauge vitrectomy is a safe, effective alternative to the more commonly used 25-gauge vitrectomy for macular surgery. Less manipulation was required to achieve wound closure with 27-gauge vitrectomy using a standardized wound-closure protocol. Smaller 27-gauge vitrectomy did not increase surgical time or complications over 25-gauge vitrectomy for macular surgery.","PeriodicalId":17919,"journal":{"name":"Journal of VitreoRetinal Diseases","volume":"12 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2023-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of VitreoRetinal Diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/24741264231209587","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the effectiveness of and to compare vitrectomy performed with 25-gauge or 27-gauge instrumentation for macular surgery. The surgical duration, wound closure, and complication rate using a systematic approach to wound closure were assessed. Methods: In this retrospective chart review, 125 25-gauge and 125 27-gauge consecutive small-gauge vitrectomy surgeries for epiretinal membrane, macular hole, vitreomacular adhesion, or a combination were analyzed during and immediately after surgery. Wound closure was performed using a systematic protocol. Results: Baseline characteristics were not statistically different between the 2 groups. The surgical duration was similar with 25-gauge vitrectomy and 27-gauge vitrectomy ( P = .07). Although spontaneous wound closure was common in both groups, it was more common in the 27-gauge group ( P = .22). Intraoperative and postoperative complications were uncommon in both groups. Conclusions: Findings show that 27-gauge vitrectomy is a safe, effective alternative to the more commonly used 25-gauge vitrectomy for macular surgery. Less manipulation was required to achieve wound closure with 27-gauge vitrectomy using a standardized wound-closure protocol. Smaller 27-gauge vitrectomy did not increase surgical time or complications over 25-gauge vitrectomy for macular surgery.