Analysis of suspended solids emissions from a combined sewage system using the Stormwater Management Model (SWMM)

IF 0.4 Q4 ENVIRONMENTAL SCIENCES
G. Sakson
{"title":"Analysis of suspended solids emissions from a combined sewage system using the Stormwater Management Model (SWMM)","authors":"G. Sakson","doi":"10.7494/geol.2023.49.4.389","DOIUrl":null,"url":null,"abstract":"The protection of water bodies requires the reduction of pollutant emissions from all major sources. In urbanized areas, these include: wastewater treatment plants (WWTPs) and (depending on the type of sewage system) combined sewer overflows (CSOs) and stormwater drainage outlets. WWTPs are usually monitored and emitted pollutant loads are known, but it is more difficult to assess the pollutant load discharged by CSOs and stormwater drainage systems. The article attempts to use the Stormwater Management Model (SWMM) to assess emissions of suspended solids from a large urban combined catchment. Suspended solids are the main pollutant of stormwater runoff in urban areas, and the dynamics of their emission from catchments is very diverse. The amount of suspended solids discharged by CSOs functioning in the given city was assessed in comparison with emissions from a wastewater treatment plant. The results show that CSOs discharge a pollutant load to the receiver which is comparable to WWTPs, but in a much shorter time and in a violent manner which can lead to the severe deterioration of receiving water quality. The modelling took into account the quality of dry weather sewage, the build-up of suspended solids, wash-off processes in the catchment area, and local precipitation characteristics. Factors affecting the quality of the obtained model and the accuracy of the emission level assessment were analysed.","PeriodicalId":12724,"journal":{"name":"Geology, Geophysics and Environment","volume":"93 2","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geology, Geophysics and Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7494/geol.2023.49.4.389","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The protection of water bodies requires the reduction of pollutant emissions from all major sources. In urbanized areas, these include: wastewater treatment plants (WWTPs) and (depending on the type of sewage system) combined sewer overflows (CSOs) and stormwater drainage outlets. WWTPs are usually monitored and emitted pollutant loads are known, but it is more difficult to assess the pollutant load discharged by CSOs and stormwater drainage systems. The article attempts to use the Stormwater Management Model (SWMM) to assess emissions of suspended solids from a large urban combined catchment. Suspended solids are the main pollutant of stormwater runoff in urban areas, and the dynamics of their emission from catchments is very diverse. The amount of suspended solids discharged by CSOs functioning in the given city was assessed in comparison with emissions from a wastewater treatment plant. The results show that CSOs discharge a pollutant load to the receiver which is comparable to WWTPs, but in a much shorter time and in a violent manner which can lead to the severe deterioration of receiving water quality. The modelling took into account the quality of dry weather sewage, the build-up of suspended solids, wash-off processes in the catchment area, and local precipitation characteristics. Factors affecting the quality of the obtained model and the accuracy of the emission level assessment were analysed.
利用雨水管理模型(SWMM)分析联合污水处理系统的悬浮固体排放量
保护水体需要减少所有主要污染源的污染物排放。在城市化地区,这些污染源包括:污水处理厂(WWTPs)和(取决于污水系统的类型)联合污水溢流(CSOs)以及雨水排放口。污水处理厂通常受到监控,排放的污染物负荷也是已知的,但要评估 CSO 和雨水排水系统排放的污染物负荷则较为困难。本文尝试使用雨水管理模型(SWMM)来评估一个大型城市联合集水区的悬浮固体排放量。悬浮固体是城市地区雨水径流的主要污染物,其从集水区排放的动态变化非常多样。通过与污水处理厂的排放量进行比较,评估了特定城市中运行的 CSO 排放的悬浮固体量。结果表明,CSO 向受纳水体排放的污染物量与污水处理厂相当,但时间更短,排放方式更猛烈,可能导致受纳水体水质严重恶化。建模时考虑了旱季污水的水质、悬浮固体的堆积、集水区的冲刷过程以及当地的降水特征。对影响所获模型质量和排放水平评估准确性的因素进行了分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
7
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信