The relationship of preterm birth with fetal fibronectin level in cervicovaginal fluid and cervical lenght in ultrasonography

Anıl Arpaci, Oya SOYLU KARAPINAR
{"title":"The relationship of preterm birth with fetal fibronectin level in cervicovaginal fluid and cervical lenght in ultrasonography","authors":"Anıl Arpaci, Oya SOYLU KARAPINAR","doi":"10.17944/interdiscip.1329535","DOIUrl":null,"url":null,"abstract":"Objective: In this study, the compatibility between fetal fibronectin determination and the use of cervical length measured by transvaginal ultrasonography of patients who were at risk of preterm birth in the examination performed at 24-34 weeks of gestation, and patients with an increased risk of preterm birth according to the result were defined. Method: 40 patients who applied to Mustafa Kemal University Training and Research Hospital Gynecology and Obstetrics outpatient clinic between May 2021 and May 2022 were included in the study. Fibronectin results were evaluated using the liquid ELISA method taken from the vaginal secretion by a swap. Cervical lengths were evaluated as 25 mm and below, between 25-30 mm and 30 mm and above in statistical data. Results: For fFN-positive patients, the preterm delivery rate of patients with a cervical length of 25 mm and less was determined as 100%, while the rate of preterm birth was determined as 77.8% for patients with a cervical length between 25 mm and 30 mm. In addition, the preterm labor rate of fFN-positive patients with a cervical length of 30 mm and above was determined as 78.57%. Conclusion: All patients with a cervical length of 25 mm or less have a positive fFN test, and a strong correlation can be established between these two values. Accordingly, fFN positivity was found to have a higher sensitivity in determining the probability of preterm delivery compared to the cervical length ratio.","PeriodicalId":402691,"journal":{"name":"Interdisciplinary Medical Journal","volume":"87 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interdisciplinary Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17944/interdiscip.1329535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In this study, the compatibility between fetal fibronectin determination and the use of cervical length measured by transvaginal ultrasonography of patients who were at risk of preterm birth in the examination performed at 24-34 weeks of gestation, and patients with an increased risk of preterm birth according to the result were defined. Method: 40 patients who applied to Mustafa Kemal University Training and Research Hospital Gynecology and Obstetrics outpatient clinic between May 2021 and May 2022 were included in the study. Fibronectin results were evaluated using the liquid ELISA method taken from the vaginal secretion by a swap. Cervical lengths were evaluated as 25 mm and below, between 25-30 mm and 30 mm and above in statistical data. Results: For fFN-positive patients, the preterm delivery rate of patients with a cervical length of 25 mm and less was determined as 100%, while the rate of preterm birth was determined as 77.8% for patients with a cervical length between 25 mm and 30 mm. In addition, the preterm labor rate of fFN-positive patients with a cervical length of 30 mm and above was determined as 78.57%. Conclusion: All patients with a cervical length of 25 mm or less have a positive fFN test, and a strong correlation can be established between these two values. Accordingly, fFN positivity was found to have a higher sensitivity in determining the probability of preterm delivery compared to the cervical length ratio.
早产与宫颈阴道液中胎儿纤维连接蛋白水平及超声检查中宫颈长度的关系
研究目的本研究明确了在妊娠 24-34 周进行的检查中,胎儿纤连蛋白测定与经阴道超声测量宫颈长度的使用之间的兼容性,以及根据该结果早产风险增加的患者。 方法研究对象包括2021年5月至2022年5月期间到穆斯塔法-凯末尔大学培训与研究医院妇产科门诊就诊的40名患者。纤连蛋白的检测结果采用液体酶联免疫吸附法进行评估,该方法从交换的阴道分泌物中提取。在统计数据中,宫颈长度被评估为 25 毫米及以下、25-30 毫米之间和 30 毫米及以上。 结果对于 fFN 阳性患者,宫颈长度在 25 毫米及以下的早产率为 100%,而宫颈长度在 25 毫米至 30 毫米之间的早产率为 77.8%。此外,宫颈长度在 30 毫米及以上的 fFN 阳性患者的早产率为 78.57%。 结论所有宫颈长度在 25 毫米或以下的患者都有 fFN 检测阳性,这两个值之间有很强的相关性。因此,与宫颈长度比值相比,fFN 阳性在确定早产概率方面具有更高的灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信