{"title":"Deflection Monitoring Method for Simply Supported Girder Bridges Using Strain Response under Traffic Loads","authors":"Yongsheng Tang, Jigang Cang, Bohan Zheng, Wei Tang","doi":"10.3390/buildings14010070","DOIUrl":null,"url":null,"abstract":"Deflection measurements are usually used as a key index in civil engineering for performing structural assessments of bridge safety. However, owing to technical or cost issues, it may be difficult to implement long-term monitoring of bridge deflection, especially for short- or medium-span bridges. Therefore, this study presents a novel method for measuring the deflection of simply supported girder bridges. In the proposed method, the strain measurement was implemented under traffic loading at only one position, such as middle span, and then the strain distribution along the girder was reconstructed to calculate the girder deflection with basic structural mechanical theory. To implement the method, the theory was constructed based on the displacement reciprocal theorem at first to assess the strain distribution along the girder from the strain measurement at some position during traffic loads passing across the bridge. Second, a strain measurement method, namely long-gauge fibre Bragg grating (FBG) sensing technology, was introduced to take strain measurements for a concrete bridge. Third, various finite element (FE) bridge models were developed to validate the proposed method’s accuracy, the results from which indicated that the method accurately implemented deflection measurement with an approximately 5% calculation error. In addition, the influence of some key parameters, such as vehicle type, vehicle speed, and structural damage, was investigated. The simulation results revealed that damage to the hinge joint in the middle location could significantly influence the proposed method’s accuracy such that the error may exceed 10%. Finally, on-site experiments were conducted on a simply supported girder bridge to further validate the proposed method’s accuracy, and an approximately 8% deflection assessment error was found. Considering the additional advantages of FBG sensing technology, the proposed method can also be effective for long-term deflection measurements of short- or medium-span bridges.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"86 1","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2023-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Buildings","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/buildings14010070","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Deflection measurements are usually used as a key index in civil engineering for performing structural assessments of bridge safety. However, owing to technical or cost issues, it may be difficult to implement long-term monitoring of bridge deflection, especially for short- or medium-span bridges. Therefore, this study presents a novel method for measuring the deflection of simply supported girder bridges. In the proposed method, the strain measurement was implemented under traffic loading at only one position, such as middle span, and then the strain distribution along the girder was reconstructed to calculate the girder deflection with basic structural mechanical theory. To implement the method, the theory was constructed based on the displacement reciprocal theorem at first to assess the strain distribution along the girder from the strain measurement at some position during traffic loads passing across the bridge. Second, a strain measurement method, namely long-gauge fibre Bragg grating (FBG) sensing technology, was introduced to take strain measurements for a concrete bridge. Third, various finite element (FE) bridge models were developed to validate the proposed method’s accuracy, the results from which indicated that the method accurately implemented deflection measurement with an approximately 5% calculation error. In addition, the influence of some key parameters, such as vehicle type, vehicle speed, and structural damage, was investigated. The simulation results revealed that damage to the hinge joint in the middle location could significantly influence the proposed method’s accuracy such that the error may exceed 10%. Finally, on-site experiments were conducted on a simply supported girder bridge to further validate the proposed method’s accuracy, and an approximately 8% deflection assessment error was found. Considering the additional advantages of FBG sensing technology, the proposed method can also be effective for long-term deflection measurements of short- or medium-span bridges.
期刊介绍:
BUILDINGS content is primarily staff-written and submitted information is evaluated by the editors for its value to the audience. Such information may be used in articles with appropriate attribution to the source. The editorial staff considers information on the following topics: -Issues directed at building owners and facility managers in North America -Issues relevant to existing buildings, including retrofits, maintenance and modernization -Solution-based content, such as tips and tricks -New construction but only with an eye to issues involving maintenance and operation We generally do not review the following topics because these are not relevant to our readers: -Information on the residential market with the exception of multifamily buildings -International news unrelated to the North American market -Real estate market updates or construction updates