{"title":"Ultrasound guided injection with Collagen-based Medical Device: real-life evaluation of efficacy and safety in hip osteoarthritis.","authors":"Nemanja Damjanov, Mihaela C Micu","doi":"10.11152/mu-4242","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Data regarding the treatment of hip osteoarthritis (OA) with collagen-based extracellular bio-scaffolds are lacking. We evaluated the treatment of hip OA with ultrasound guided intraarticular injections of Collagen-based Medical Device (CMD).</p><p><strong>Material and methods: </strong>Forty-four patients with Kellgren-Lawrence grade (KLG) I or II were selected, and 20/44 randomly selected patients (CMD group), were treated with 2 weekly consecutive ultrasound guided intraarticular injections of CMD (MD-HIP, Guna S.p.a. Milan, Italy). An additional 24/44 patients were treated with oral non-steroidal anti-inflammatory drugs (NSAIDs) daily (NSAIDs group). Clinical assessment, X-rays and ultrasound evaluation were performed at baseline, and after 1 month in both groups, and after 3 months in the CMD group. Outcome measures were general pain VAS (0-10), the whole WOMAC score, and the WOMAC specific subscores.</p><p><strong>Results: </strong>CMD and NSAIDs group were homogenous for age, gender, VAS pain and WOMAC scores. The CMD group had significant improvement of the VAS pain (p<0.0001), global WOMAC score (p<0.0001) and WOMAC function (p<0.0001) from baseline to the 1st month, with further improvement from the 1st to the 3rd month (p<0,001; p<0.01; p<0.03, respectively). Significant improvement in WOMAC pain (p<0.0001) and WOMAC stiffness (p<0.0001) was detected at 1st month, with no significant change at 3rd month. In the NSAIDs group significant improvement in WOMAC function was detected after 1 month (p=0.021) only. No adverse events were recorded in the CMD and NSAIDs group.</p><p><strong>Conclusion: </strong>The ultrasound guided intraarticular hip injections of CMD resulted in significant improvement in VAS pain and WOMAC scores compared to treatment with oral NSAIDs.</p>","PeriodicalId":94138,"journal":{"name":"Medical ultrasonography","volume":" ","pages":"26-31"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical ultrasonography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11152/mu-4242","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/26 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: Data regarding the treatment of hip osteoarthritis (OA) with collagen-based extracellular bio-scaffolds are lacking. We evaluated the treatment of hip OA with ultrasound guided intraarticular injections of Collagen-based Medical Device (CMD).
Material and methods: Forty-four patients with Kellgren-Lawrence grade (KLG) I or II were selected, and 20/44 randomly selected patients (CMD group), were treated with 2 weekly consecutive ultrasound guided intraarticular injections of CMD (MD-HIP, Guna S.p.a. Milan, Italy). An additional 24/44 patients were treated with oral non-steroidal anti-inflammatory drugs (NSAIDs) daily (NSAIDs group). Clinical assessment, X-rays and ultrasound evaluation were performed at baseline, and after 1 month in both groups, and after 3 months in the CMD group. Outcome measures were general pain VAS (0-10), the whole WOMAC score, and the WOMAC specific subscores.
Results: CMD and NSAIDs group were homogenous for age, gender, VAS pain and WOMAC scores. The CMD group had significant improvement of the VAS pain (p<0.0001), global WOMAC score (p<0.0001) and WOMAC function (p<0.0001) from baseline to the 1st month, with further improvement from the 1st to the 3rd month (p<0,001; p<0.01; p<0.03, respectively). Significant improvement in WOMAC pain (p<0.0001) and WOMAC stiffness (p<0.0001) was detected at 1st month, with no significant change at 3rd month. In the NSAIDs group significant improvement in WOMAC function was detected after 1 month (p=0.021) only. No adverse events were recorded in the CMD and NSAIDs group.
Conclusion: The ultrasound guided intraarticular hip injections of CMD resulted in significant improvement in VAS pain and WOMAC scores compared to treatment with oral NSAIDs.